Zayd Anwar

Dr. Zayd Anwar


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JYJia-Ruei Yu
Jia-Ruei Yu
YWYu-Tan Wu
Yu-Tan Wu
YSYi-Juan Sung
Yi-Juan Sung
TCTzong-Shi Chiueh
Tzong-Shi Chiueh
WYWei-Hsuan Yu
Wei-Hsuan Yu
Hsin-Yao WangHsin-Yao Wang
Hsin-Yao Wang
Capillary zone electrophoresis–immunosubtraction (CZE-IS) is an essential laboratory test in diagnosing plasma cell neoplasms. However, the current interpretation of the test results is subjective. To evaluate CZE-IS in a more precise manner, this study proposed five key indexes, namely sharpness index, light chain index, immunoglobulin G index, immunoglobulin A index, and immunoglobulin M index. The reference intervals of these indexes were established using CZE-IS curve data from a clinical laboratory of a referral medical center. A total of 1000 cases with normal electrophoretic patterns were sampled for reference intervals establishment, and an additional 20 cases were included for validation. The following reference intervals in the γ zone were established: 1-6 (sharpness index), 1.06-2.71 (light chain index), 37-454 (immunoglobulin G index), (−9)-41 (immunoglobulin A index), and (−16)-46 (immunoglobulin M index). For the β2 zone, the reference intervals were 3-17 (sharpness index), 0.44-1.90 (light chain index), (−7)-61 (immunoglobulin G index), 2-117 (immunoglobulin A index), and (−12)-35 (immunoglobulin M index). The diagnostic performance of reference intervals of the proposed indexes in validation ranged from 95% to 100%. CZE-IS indexes provide the objective quantification of key characteristics of CZE-IS curves and improve the precision of CZE-IS interpretation.

1 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JYJia-Ruei Yu
Jia-Ruei Yu
YWYu-Tan Wu
Yu-Tan Wu
YSYi-Juan Sung
Yi-Juan Sung
TCTzong-Shi Chiueh
Tzong-Shi Chiueh
WYWei-Hsuan Yu
Wei-Hsuan Yu
Hsin-Yao WangHsin-Yao Wang
Hsin-Yao Wang
Capillary zone electrophoresis-immunosubtraction (CZE-IS) is an essential laboratory test in diagnosing plasma cell neoplasms. However, current interpretation of the test results is subjective. To evaluate CZE-IS in a more precise manner, this study proposed five key indexes, namely sharpness index, light chain index, immunoglobulin G index, immunoglobulin A index, and immunoglobulin M index. The reference intervals of these indexes were established using CZE-IS curve data from a clinical laboratory of a referral medical center. A total of 1000 cases with normal electrophoretic patterns were sampled for reference interval establishment, and additional 20 cases were included for validation. The reference intervals in the γ zone were established: 1–6 (sharpness index), 1.06–2.71 (light chain index), 37–454 (immunoglobulin G index), (-9)–41 (immunoglobulin A index), and (-16)–46 (immunoglobulin M index). For the β2 zone, the reference intervals were 3–17 (sharpness index), 0.44–1.90 (light chain index), (-7)–61 (immunoglobulin G index), 2–117 (immunoglobulin A index), and (-12)–35 (immunoglobulin M index). The diagnostic performance of reference intervals of the proposed indexes in validation ranged from 95% to 100%. CZE-IS indexes provide the objective quantification of key characteristics in CZE-IS curves, and improve the precision of CZE-IS interpretation.

24 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
Hsin-Yao WangHsin-Yao Wang
Hsin-Yao Wang
WLWan-Ying Lin
Wan-Ying Lin
CZChenfei Zhou
Chenfei Zhou
JXJennifer Xu
Jennifer Xu
ZAZayd Anwar
Zayd Anwar
MLMichael S Lebowitz
Michael S Lebowitz
Background: Capillary blood sampling may improve access to multi-cancer early detection (MCED) by enabling less invasive and more decentralized specimen collection. However, its paired-specimen measurement agreement with conventional venous blood for protein biomarker-based MCED testing requires validation. Objective: The objective of this study was to evaluate agreement between capillary and venous blood specimens for OneTest protein biomarkers and to assess the exact risk category agreement of the OneTest Premium algorithm outputs generated from both specimen types. Methods: This two-stage study compared paired venous and capillary blood specimens. Study 1 enrolled 143 Taiwanese adults undergoing clinically indicated biomarker testing to evaluate paired-specimen measurement agreement. Study 2 involved an exploratory paired-specimen evaluation in 13 asymptomatic U.S. volunteers using an upper arm capillary blood collection device. Biomarker concentrations were compared using paired statistical testing, correlation analysis, and Bland–Altman analysis. OneTest Premium risk categories and cancer type prediction outputs were compared between specimen types. Results: In Study 1, no statistically significant differences were observed between capillary and venous specimens for any evaluated biomarker. Descriptive scatterplots showed strong linear associations between paired capillary and venous biomarker measurements across the observed concentration ranges. Bland–Altman analysis showed mean biases close to zero for most biomarkers, with biomarker-specific limits of agreement. In Study 2, all 12 biomarkers were successfully measured in all 13 participants. OneTest Premium risk categorization was concordant in 11 of 13 participants; discordant cases involved adjacent low-risk and mild-risk categories, with no major or very major classification errors. Given the small sample size, these findings are descriptive and preliminary. Conclusions: Capillary blood specimens showed paired measurement agreement with venous specimens in Study 1. The exploratory findings from Study 2 suggest that capillary-derived measurements may support the generation of OneTest Premium outputs.