KAZURO YABUKI

Dr. KAZURO YABUKI

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TTTakeshi Teshigawara
Takeshi Teshigawara
MAMiki Akaishi
Miki Akaishi
YMYuki Mizuki
Yuki Mizuki
MTMasaki Takeuchi
Masaki Takeuchi
KYKAZURO YABUKI
KAZURO YABUKI
NMNobuhisa Mizuki
Nobuhisa Mizuki
Background/Objectives: Meibomian gland dysfunction (MGD)-related dry eye aggravates postoperative visual outcomes in cataracts. Diffractive trifocal intraocular lenses (IOLs) decrease contrast sensitivity (CS). Intense pulsed light (IPL) improves tear film stability and ocular surface conditions in MGD-related dry eyes. We investigated the effect of preoperative MGD-related dry eye treatment combining manual meibomian gland expression (MGX) with IPL (IPL-MGX) on visual outcomes post-cataract surgery with diffractive trifocal IOL implantation. Methods: In this single-center, prospective, and open-label study, we enrolled 67 patients (134 eyes) with MGD-related dry eye undergoing cataract surgery on both eyes. Preoperatively, IPL-MGX was performed on one eye (IPL-MGX group) but not the contralateral eye (control group). Tear break-up time, high-order aberrations, and central superficial punctate keratopathy (C-SPK) were assessed. CS and corrected distance visual acuity were analyzed. Differences between groups were analyzed at 1 week, 1 month, and 3 months postoperatively. Results: The IPL-MGX group showed greater mean tear break-up time and lower mean high-order aberration and C-SPK values after preoperative IPL treatment and postoperatively (all p < 0.01). Postoperative CS was higher in the IPL-MGX group at 1 week (all spatial frequencies) (p < 0.01 [cpd = 2.9, 4.5, 7.1, and 10.2] and p < 0.05 [cpd = 1.1 and 1.8]); 1 month [2.9–10.2 cpd] (p < 0.01); and 3 months [4.5–10.2 cpd] (p < 0.01 [cpd = 10.2] and p < 0.05 [cpd = 4.5 and 7.1]) postoperatively. Mean corrected distance visual acuity was higher in the IPL-MGX group only postoperatively (p < 0.01). Conclusions: Preoperative MGD-related dry eye treatment using IPL-MGX enhances tear film stability, ocular surface conditions, and visual outcomes, potentially improving postoperative vision quality and patient satisfaction.

18 April 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TKTatsukata Kawagoe
Tatsukata Kawagoe
YMYuki Mizuki
Yuki Mizuki
MAMiki Akaishi
Miki Akaishi
MTMasaki Takeuchi
Masaki Takeuchi
KYKAZURO YABUKI
KAZURO YABUKI
TTTakeshi Teshigawara
Takeshi Teshigawara
Objective: This research seeks to investigate the effects of preoperative intense pulsed light with manual meibomian expression (IPL-MGX) on the refractive accuracy of cataract surgery on dry eyes with meibomian gland dysfunction (MGD-related dry eyes). Methods: Fifty-six MGD-related dry eye cases planned for cataract surgery were analyzed. IPL-MGX (four times at 2-week intervals) was performed before preoperative examination. Axial length (AL), anterior chamber depth (ACD), corneal curvature (mean-K), tear break-up time (TBUT), superficial punctate keratopathy in the central cornea (C-SPK), corneal higher-order aberrations (HOAs), and predicted postoperative spherical equivalent (P-SE) were evaluated pre- and post-IPL-MGX. The postoperative subjective spherical equivalent (S-SE) was evaluated after one month. The absolute difference between the S-SE and P-SE was considered an indication of P-SE accuracy. Changes in all the variables were assessed before and after IPL-MGX treatment. Results: No significant differences were observed in AL or ACD (p = 0.85, 0.56). The differences in mean-K, TBUT, C-SPK, and HOAs were significant (p < 0.01). P-SE accuracy based on post-IPL-MGX data was significantly higher than that based on pre-IPL-MGX data (p < 0.01). P-SE accuracy was within 0.25 diopters (D) in 14.3% of pre- and 55.4% of post-IPL-MGX, within 0.5D in 55.4% of pre- and 92.9% of post-IPL-MGX, within 0.75D in 98.2% of pre- and post-IPL-MGX, and within 1.0D in 98.2% of pre- and 100% of post-IPL-MGX. In the range of 0.25 and 0.5 D, the accuracy of P-SE was significantly higher in post-IPL-MGX (p < 0.01). Conclusions: Preoperative IPL-MGX considerably improved the predicted postoperative refraction accuracy in patients with MGD-related dry eye undergoing cataract surgery.

1 October 2018 in International Medical Case Reports Journal
Verified
Journal Article
Open access
PDF file
TTTakeshi Teshigawara
Takeshi Teshigawara
AMAkira Meguro
Akira Meguro
KYKAZURO YABUKI
KAZURO YABUKI
SHSeiichiro Hata
Seiichiro Hata
NMNobuhisa Mizuki
Nobuhisa Mizuki
At present, only one design is available for trifocal intraocular lens (IOL); unfortunately, this particular design is not suitable for implantation in the sulcus with optic capture when posterior capsule rupture (PCR) occurs. Although three-piece bifocal IOLs can be implanted in the sulcus, this form of IOL can be vulnerable to tilt and decentration, thus causing aberration and photopic phenomena, such as halos and glares. However, visual axis centered optic capture using femtosecond laser-assisted cataract surgery (FLACS) is able to manage such complex operations. In the present study, we implanted a three-piece +4.0 D bifocal IOL into the sulcus of a patient who experienced PCR using optic capture and FLACS following the straightforward implantation of a one-piece trifocal IOL in the other eye. Defocus curves showed that the weakness of the trifocal IOL (nearest distances) was compensated for by the strength of the +4.0 D bifocal IOL, whereas the weakness of the +4.0 D bifocal IOL (middle distance) was compensated for by the strength of the trifocal IOL. Therefore, this combination provided the patient with a wider range of depth of focus. The contrast sensitivity in both eyes was within the normal range. Photopic phenomena were comparable with the bilateral implantation of the trifocal IOL. Anterior segment optical coherence tomography showed that tilt and decentration in the trifocal IOL implanted in the bag was significantly higher than the +4.0 D bifocal IOL implanted in the visual axis centered optic capture. This case showed that the intraindividual implantation of a single-piece trifocal IOL in the bag and a three-piece +4.0 D bifocal IOL in the sulcus, using a combination of optic capture and FLACS, is promising particularly in cases of PCR and can provide a wider range of vision without losing visual quality.

18 December 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TTTakeshi Teshigawara
Takeshi Teshigawara
TKTatsukata Kawagoe
Tatsukata Kawagoe
YMYuki Mizuki
Yuki Mizuki
MAMiki Akaishi
Miki Akaishi
TSTakuto Sakono
Takuto Sakono
NMNobuhisa Mizuki
Nobuhisa Mizuki
Objectives: To compare the effects of two preoperative dry eye treatments—3% diquafosol sodium (DQS) and intense pulsed light with meibomian gland expression (IPL-MGX)—on refractive accuracy in cataract surgery and identify tear break-up time (TBUT) thresholds predictive of refractive success. Methods: In this prospective, paired-eye study, 62 patients (124 eyes) with meibomian gland dysfunction underwent bilateral cataract surgery with the same trifocal intraocular lens. One eye received DQS, while the fellow eye underwent four IPL-MGX sessions before biometry. Postoperative absolute prediction error (P-SE) was compared. TBUT and higher-order aberrations (HOAs) were evaluated. Logistic regression identified predictors of refractive accuracy, and receiver operating characteristic (ROC) analysis assessed the predictive value of TBUT for P-SE thresholds of <0.25 D and <0.50 D. Results: P-SE was significantly lower in IPL-MGX–treated eyes than in DQS-treated eyes (mean paired difference −0.11 D, p < 0.001). Success rates within <0.25 D and <0.50 D were higher with IPL-MGX (p < 0.01). TBUT and HOAs were predictors in univariate models, but only TBUT remained significant in the multivariable analysis (odds ratio, 4.90 per 1-s increase; 95% confidence interval, 1.92–12.51; p < 0.001). ROC analysis supported TBUT cutoffs of 7 s (<0.25 D) and 6 s (<0.50 D). Conclusions: IPL-MGX may improve refractive accuracy compared to DQS. TBUT appeared to be the most consistent predictor, and achieving ≥6 s was associated with higher likelihood of refractive success.