Jean-Marc PELLETIER

Prof. Jean-Marc PELLETIER


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2013 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
JQJichao Qiao
Jichao Qiao
JPJean-Marc PELLETIER
Jean-Marc PELLETIER
RCRiccardo Casalini
Riccardo Casalini

21 March 2014 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
JQJichao Qiao
Jichao Qiao
RCRiccardo Casalini
Riccardo Casalini
JPJean-Marc PELLETIER
Jean-Marc PELLETIER
HKHidemi Kato
Hidemi Kato

1 January 2017 in Chinese Physics B
Verified
Journal Article
Open access
PDF file
JQJichao QIAO
Jichao QIAO
QWQ Wang
Q Wang
DCDaniel Crespo
Daniel Crespo
Yong YangYong Yang
Yong Yang
JPJean-Marc PELLETIER
Jean-Marc PELLETIER

6 February 2018 in Materials
Verified
Journal Article
Open access
PDF file
ALALETHEA LIENS
ALETHEA LIENS
AEAurélien Etiemble
Aurélien Etiemble
PRPascaline Rivory
Pascaline Rivory
SBSandra Balvay
Sandra Balvay
JPJean-Marc PELLETIER
Jean-Marc PELLETIER
Jérôme ChevalierJérôme Chevalier
Jérôme Chevalier
Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on machined implant-abutment assemblies. The results were compared to the benchmark Ti-6Al-4V ELI (Extra-Low-Interstitial) to assess its potential in dental implantology. The thermal stability, corrosion and sterilization resistance, cytocompatibility and mechanical properties were measured on samples with a simple geometry, but also on implant-abutment assemblies’ prototypes. Results show that the glassy alloy exhibits a quite high thermal stability, with a temperature range of 38 °C between the glass transition and crystallization, a compressive strength of 2 GPa, a certain plastic deformation (0.7%), a hardness of 5.5 GPa and a toughness of 56 MPa.√m. Moreover, the alloy shows a relatively lower Young’s modulus (96 GPa) than the Ti-6Al-4V alloy (110–115 GPa), which is beneficial to limit bone stress shielding. The BMG shows a satisfactory cytocompatibility, a high resistance to sterilization and a good corrosion resistance (corrosion potential of −0.07 V/SCE and corrosion current density of 6.0 nA/cm2), which may ensure its use as a biomaterial. Tests on dental implants reveal a load to failure 1.5-times higher than that of Ti-6Al-4V and a comparable fatigue limit. Moreover, implants could be machined and sandblasted by methods usually conducted for titanium implants, without significant degradation of their amorphous nature. All these properties place this metallic glass among a promising class of materials for mechanically-challenging applications such as dental implants.

26 February 2024 in International Journal of Plasticity
Verified
Journal Article
Closed access
QHQ. Hao
Q. Hao
GLG.J. Lyu
G.J. Lyu
EPEloi Pineda
Eloi Pineda
JPJean-Marc PELLETIER
Jean-Marc PELLETIER
YWYunjiang Wang
Yunjiang Wang
JQJichao Qiao
Jichao Qiao