Yong Yin

Dr. Yong Yin


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
GGGuanzhong Gong
Guanzhong Gong
RWRuozheng Wang
Ruozheng Wang
YGYujie Guo
Yujie Guo
DZDeyin Zhai
Deyin Zhai
TLtonghai hai Liu
tonghai hai Liu
YYYong Yin
Yong Yin
Background: Lung radiation injury is a critical complication of radiotherapy (RT) for thoracic esophageal carcinoma (EC). Therefore, the goal of this study was to investigate the feasibility and dosimetric effects of reducing the lung tissue irradiation dose during RT for thoracic EC by applying volumetric modulated arc radiotherapy (VMAT) combined with active breathing control (ABC) for moderate deep inspiration breath-hold (mDIBH). Methods: Fifteen patients with thoracic EC were randomly selected to undergo two series of computed tomography (CT) simulation scans with ABC used to achieve mDIBH (representing 80% of peak DIBH value) versus free breathing (FB). Gross tumor volumes were contoured on different CT images, and planning target volumes (PTVs) were obtained using different margins. For PTV-FB, intensity-modulated radiotherapy (IMRT) was designed with seven fields, and VMAT included two whole arcs. For PTV-DIBH, VMAT with three 135° arcs was applied, and the corresponding plans were named: IMRT-FB, VMAT-FB, and VMAT-DIBH, respectively. Dosimetric differences between the different plans were compared. Results: The heart volumes decreased by 19.85%, while total lung volume increased by 52.54% in mDIBH, compared to FB (p < 0.05). The mean conformality index values and homogeneity index values for VMAT-DIBH (0.86, 1.07) were slightly worse than those for IMRT-FB (0.90, 1.05) and VMAT-FB (0.90, 1.06) (p > 0.05). Furthermore, compared to IMRT-FB and VMAT-FB, VMAT-DIBH reduced the mean total lung dose by 18.64% and 17.84%, respectively (p < 0.05); moreover, the V5, V10, V20, and V30 values for IMRT-FB and VMAT-FB were reduced by 10.84% and 10.65% (p > 0.05), 12.5% and 20% (p < 0.05), 30.77% and 33.33% (p < 0.05), and 50.33% and 49.15% (p < 0.05), respectively. However, the heart dose-volume indices were similar between VMAT-DIBH and VMAT-FB which were lower than IMRT-FB without being statistically significant (p > 0.05). The monitor units and treatment time of VMAT-DIBH were also the lowest (p < 0.05). Conclusions: VMAT combined with ABC to achieve mDIBH is a feasible approach for RT of thoracic EC. Furthermore, this method has the potential to effectively reduce lung dose in a shorter treatment time and with better targeting accuracy.

4 April 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
ZFZiwei Feng
Ziwei Feng
CTCheng Tao
Cheng Tao
ZJZhu Jian
Zhu Jian
JCJinhu Chen
Jinhu Chen
GYGang Yu
Gang Yu
DLDengwang Li
Dengwang Li
For cervical carcinoma cases, this study aimed to evaluate the quality of intensity-modulated radiation therapy (IMRT) plans optimized by biological constraints. Furthermore, a new integrated strategy in biological planning module was proposed and verified. Twenty patients of advanced stage cervical carcinoma were enrolled in this study. For each patient, dose volume optimization (DVO), biological model optimization (BMO) and integrated strategy optimization (ISO) plans were created using same treatment parameters. Different biological models were also used for organ at risk (OAR) in BMO plans, which include the LKB and Poisson models. Next, BMO plans were compared with their corresponding DVO plans, in order to evaluate BMO plan quality. ISO plans were also compared with DVO and BMO plans, in order to verify the performance of the integrated strategy. BMO plans produced slightly inhomogeneity and less coverage of planning target volume (PTV) (V95=96.79, HI = 0.10: p < 0.01). However, the tumor control probability (TCP) value, both from DVO and BMO plans, were comparable. For the OARs, BMO plans produced lower normal tissue complication probability (NTCP) of rectum (NTCP = 0.11) and bladder (NTCP = 0.14) than in the corresponding DVO plans (NTCP = 0.19 and 0.18 for rectum and bladder; p < 0.01 for rectum and p = 0.03 for bladder). V95, D98, CI and HI values that were produced by ISO plans (V95 = 98.31, D98 = 54.18Gy, CI = 0.76, HI = 0.09) were greatly better than BMO plans (V95 = 96.79, D98 = 53.42Gy, CI = 0.71, HI = 0.10) with significant differences. Furthermore, ISO plans produced lower NTCP values of rectum (NTCP = 0.14) and bladder (NTCP = 0.16) than DVO plans (NTCP = 0.19 and 0.18 for rectum and bladder, respectively) with significant differences. BMO plans produced lower NTCP values of OARs compared to DVO plans for cervical carcinoma cases, and resulted in slightly less target coverage and homogeneity. The integrated strategy, proposed in this study, could improve the coverage, conformity and homogeneity of PTV greater than the BMO plans, as well as reduce the NTCP values of OARs greater than the DVO plans.

23 June 2017 in Oncology Letters
Verified
Journal Article
Open access
PDF file
XZXinli Zhang
Xinli Zhang
ZFZheng Fu
Zheng Fu
GGGuanzhong Gong
Guanzhong Gong
HWHong Wei
Hong Wei
JDJinghao Duan
Jinghao Duan
YYYong Yin
Yong Yin
Radiotherapy, particularly the target delineation of cancer based on scanned images, plays a key role in the planning of cancer treatment. Recently, diffusion-weighted magnetic resonance imaging (DW-MRI) has emerged as a prospective superior procedure compared with intensified computed tomography (CT) and positron emission tomography (PET) in the target delineation of cancer. However, the implication of DW-MRI in lung cancer, the leading cause of cancer-associated mortality worldwide, has not been extensively evaluated. In the present study, the gross target volumes of lung cancer masses delineated using the DW-MRI, CT and PET procedures were compared in a pairwise manner in a group of 27 lung cancer patients accompanied with atelectasis of various levels. The data showed that compared with CT and PET procedures, DW-MRI has a more precise delineation of lung cancer while exhibiting higher reproducibility. Together with the fact that it is non-invasive and cost-effective, these data demonstrate the great application potential of the DW-MRI procedure in cancer precision radiotherapy.

28 January 2022 in Evolutionary Bioinformatics
Verified
Journal Article
Open access
HTHongwei Tang
Hongwei Tang
QHQingtian Han
Qingtian Han
YYYong Yin
Yong Yin
Background: Osteoporosis is a bone disease that increases the patient’s risk of fracture. We aimed to identify robust marker genes related to osteoporosis based on different bioinformatic methods and multiple datasets. Methods: Three datasets from Gene Expression Omnibus (GEO) were utilized for analysis separately. Significantly differentially expressed genes (DEGs) from comparing high hip and low hip low bone mineral density (BMD) groups in the first dataset were identified for Gene Ontology (GO), Gene set enrichment analysis (GSEA) and Kyoto encyclopedia of genes and genomes (KEGG) to investigate the discrepantly enriched biological processes between high hip and low hip group. Last absolute shrinkage and selection operator (LASSO), SVM model and protein-protein interaction (PPI) regulatory network were performed and generated robust marker genes for downstream TF-target and miRNA-target prediction. Results: Several DEGs between high hip BMD group and low hip BMD group were obtained. And the metabolism-related pathways such as metabolic pathways, carbon metabolism, glyoxylate and dicarboxylate metabolism shown enrichment in these DEGs. Integration with LASSO regression analysis, 8 differential expression genes ( SH3BP1, NARF, ANKRD34B, RNF40, ZNF473, AKT1, SHMT1, and VASH1) in GSE62402 were identified as the optimal differential genes combination. Moreover, the SVM validation analysis in GSE56814 and GSE56815 datasets showed that the characteristic gene combinations presented high diagnostic effects, and the model AUC areas for GSE56814 was 0.899 and for GSE56815 was 0.921. Furthermore, the subcellular localization analysis of the 8 genes revealed that 4 proteins were located in the cytoplasm, 3 proteins were located in the nucleus, and 1 protein was located in the mitochondria. Additionally, the related TFs and miRNAs by performing TF-target and miRNA-target prediction for 5 genes ( AKT1, SHMT1, ZNF473, RNF40 and VASH1) were investigated from PPI network. Conclusion: The optimal differential genes combination ( SH3BP1, NARF, ANKRD34B, RNF40, ZNF473, AKT1, SHMT1, and VASH1) presented high diagnostic effect for osteoporosis risk.

16 October 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
HXHua Xu
Hua Xu
GGGuanzhong Gong
Guanzhong Gong
HWHong Wei
Hong Wei
LCLusheng Chen
Lusheng Chen
JCJinhu Chen
Jinhu Chen
YYYong Yin
Yong Yin
To study the feasibility and the potential benefits of defining the internal gross tumor volume (IGTV) of hepatocellular carcinoma (HCC) using contrast-enhanced 4D CT images obtained by combining arterial-phase (AP) contrast-enhanced (CE) 3D CT and non-contrast-enhanced (NCE) 4D CT images using deformable registration (DR). Ten HCC patients who had received radiotherapy beforehand were selected for this study. The following CT simulation images were acquired sequentially: NCE 4D CT in free breathing, NCE 3D CT and APCE 3D CT in end-expiration breath holding. All 4D CT images were sorted into ten phases according to breath cycle (CT00 ~ CT90). Gross tumor volumes (GTVs) were contoured on all CT images and the IGTV-1 was obtained by merging the GTVs in each phase of 4D CT images. The GTV on the APCE 3D CT image was deformably registered to each 4D CT phase image according to liver shape using RayStationTM 3.99.0.7 version treatment planning system. The IGTV-DR was obtained by merging the GTVs after DR on the 4D CT images. Volume differences among the GTVs and between the IGTV-1 and the IGTV-DR were compared. The edge of most lesions could be definitively identified using APCE 3D CT images compared to NCE 4D and 3D CT images. The GTV volume on APCE 3D CT images increased by an average of 34.79% (P < 0.05). There was no significant difference among the GTV volumes obtained using NCE 4D and 3D CT images (P > 0.05). The GTV volumes after DR on 4D CT different phase images increased by an average of 36.29% (P < 0.05), as was observed using the APCE 3D CT image (P > 0.05). Lastly, the volume of IGTV-DR increased by an average of 19.91% compared to that of IGTV-1 (P < 0.05). NCE 4D CT imaging alone has the potential risk of missing a partial volume of the HCC. The combination of APCE 3D CT and NCE 4D CT images using the DR technique improved the accuracy of the definition of the IGTV in HCC.

3 October 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
YCYongbin Cui
Yongbin Cui
YPYuteng Pan
Yuteng Pan
ZLZhenjiang Li
Zhenjiang Li
QWQiang Wu
Qiang Wu
JZJingmin Zou
Jingmin Zou
CMChangsheng Ma
Changsheng Ma
Objective: The purpose of this study is to compare the dosimetric and biological evaluation differences between photon and proton radiation therapy.Methods: Thirty esophageal squamous cell carcinoma (ESCC) patients were generated for volumetric modulated arc therapy (VMAT) planning and intensity-modulated proton therapy (IMPT) planning to compare with intensity-modulated radiation therapy (IMRT) planning. According to dose–volume histogram (DVH), dose–volume parameters of the plan target volume (PTV) and homogeneity index (HI), conformity index (CI), and gradient index (GI) were used to analyze the differences between the various plans. For the organs at risk (OARS), dosimetric parameters were compared. Tumor control probability (TCP) and normal tissue complication probability (NTCP) was also used to evaluate the biological effectiveness of different plannings.Results: CI, HI, and GI of IMPT planning were significantly superior in the three types of planning (p < 0.001, p < 0.001, and p < 0.001, respectively). Compared to IMRT and VMAT planning, IMPT planning improved the TCP (p<0.001, p<0.001, respectively). As for OARs, IMPT reduced the bilateral lung and heart accepted irradiation dose and volume. The dosimetric parameters, such as mean lung dose (MLD), mean heart dose (MHD), V5, V10, and V20, were significantly lower than IMRT or VMAT. IMPT afforded a lower maximum dose (Dmax) of the spinal cord than the other two-photon plans. What’s more, the radiation pneumonia of the left lung, which was caused by IMPT, was lower than IMRT and VMAT. IMPT achieved the pericarditis probability of heart is only 1.73% ± 0.24%. For spinal cord myelitis necrosis, there was no significant difference between the three different technologies.Conclusion: Proton radiotherapy is an effective technology to relieve esophageal cancer, which could improve the TCP and spare the heart, lungs, and spinal cord. Our study provides a prediction of radiotherapy outcomes and further guides the individual treatment.