Background: Magnetic resonance images can be affected in a number of ways by magnetic field inhomogeneity. The study aimed to optimize the main magnetic field homogeneity (MFH) by assessing how magnetic field inhomogeneity affects the signal-to-noise ratio (SNR) and geometric distortion of images acquired along the diameter of a spherical volume phantom from the isocenter of the MRI scanner. Results: The MFH ranged between 0.10 and 0.60 ppm. The best MFH and the maximum SNR were determined in the isocenter at 400 mm field of view with the application of shim. However, for all the phantom positions, geometrical distortion in images acquired at 200 mm field of view was generally better and worse at 400 mm field of view. MFH could be optimized to reduce geometrical distortion and increase SNR by increasing the receiver bandwidth and the number of excitations whiles complementing it with shimming during image acquisition. According to Chi-square independent test, there were no significant differences (p > 0.05) in the MFH, SNR, and geometrical distortion values. Compared to findings at higher field strengths, it was observed that MRI systems of higher field strengths (greater than 1.5 T) could offer superior magnetic field homogeneity and SNR without causing observable geometrical distortion. Conclusions: The optimal field of view for the fast field echo (FFE) sequence required to maximize MFH, SNR, and reduce distortion during image acquisition may vary across MRI systems of different field strengths. To determine the appropriate field of view, the method and results of this study could serve as a guide for medical physicists as part of their routine quality assurance test procedures.
Background: As newer technologies in the field of medical imaging continue to expand, development of unique techniques for optimizing image quality and minimizing radiation dose becomes very necessary for improve diagnosis of pathologies and patient safety. Different types of medical imaging devices have been developed for specific diagnostic purposes.Main text: This article provides a brief overview on the need for co-registration of some medical images into a single image (image fusion), advantages of some nanoparticle contrast agents in medical imaging, and a discussion of present and future role of integrating image fusion with nanoparticle contrast agents in diagnosis.Conclusion: The use of nanoparticle contrast agents together with image fusion is a promising technique in future medical imaging as is likely to reveal pathologies of ≤ 1 nm sizes.
17 November 2022 in Polish Journal of Medical Physics And Engineering
Various materials and compounds have been used in the design of diffusion-weighted magnetic resonance imaging (DWMRI) phantoms to mimic biological tissue properties, including diffusion. This review thus provides an overview of the preparations of the various DW-MRI phantoms available in relation to the limitations and strengths of materials/solutions used to fill them. The narrative review conducted from relevant databases shows that synthesizing all relevant compounds from individual liquids, gels, and solutions based on their identified strengths could contribute to the development of a novel multifunctional DW-MRI phantom. The proposed multifunctional material at varied concentrations, when filled into a multi-compartment Perspex container of cylindrical or spherical geometry, could serve as a standard DW-MRI phantom. The standard multifunctional phantom could potentially provide DW-MRI quality control test parameters in one study session.