Ayse Bilgen Aksoy

Dr. Ayse Bilgen Aksoy

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAyse Bilgen Aksoy
Ayse Bilgen Aksoy
YÇYunus Çerçi
Yunus Çerçi
Improving the thermodynamic and economic performance of industrial refrigeration systems is essential for reducing energy consumption and enhancing cold chain sustainability. This study presents an integrated energy, exergy, and exergoeconomic assessment of a full-scale two-stage ammonia (R717) vapor compression refrigeration system operating under real industrial conditions in Türkiye. Experimental data from 33 measurement points were used to perform component-level thermodynamic balances under steady-state conditions. The results showed that the evaporative condenser exhibited the highest heat transfer rate (426.7 kW), while the overall First Law efficiency of the system was 63.71%. Exergy analysis revealed that heat exchangers are the dominant sources of irreversibility (>45%), followed by circulation pumps with a notably low Second Law efficiency of 11.56%. The exergoeconomic assessment identified the circulation pumps as the components with the highest loss-to-cost ratio (2.45 W/USD). An uncertainty analysis confirmed that the relative ranking of system components remained robust within the measurement uncertainty bounds. The findings indicate that, although the existing NH3 configuration provides adequate performance, significant improvements can be achieved by prioritizing pump optimization, maintaining higher compressor loading, and implementing advanced variable-speed fan control strategies.

9 June 2022 in Mühendis ve Makina
Verified
Journal Article
Closed access
FBFevzi BALKAN
Fevzi BALKAN
AAAyse Bilgen Aksoy
Ayse Bilgen Aksoy
Soğuk hava depoları, gıdaların tazeliklerinin korunması hususunda büyük öneme sahiptir. Gıdaların besin değerlerini koruyabilmeleri, oda havasının doğru sıcaklık ve nemde şartlandırılmasına bağlıdır. Sıcaklık ve nem dengesi evaporatörlerden ortama sağlanan şartlandırılmış hava ile gerçekleştirilir. Bu çalışmada; soğuk hava depolarında, soğuk havanın depo ortamına dağılımını sağlamak amacıyla kullanılan evaporatörlerin odaya yerleşim yerlerinin, sıcaklık ve hız dağılımlarına hava akışının sebep olduğu ürün kayıplarına etkisi incelenmiştir. Deneysel çalışma, içerisinde narenciye bulunan soğuk odada gerçekleştirilmiştir. Deneysel çalışmalarda elde edilen veriler, aynı depo şartları için CFD programında simüle edilerek karşılaştırılmış ve sonuçların örtüştüğü ve kullanılabilirliği belirlenmiştir. Çeşitli evaporatör konumlandırmaları simüle edilerek, sıcaklıkları ve ürün istifleme şartları belirlenmeye çalışılmıştır. Evaporatörün tek duvarda konumlandırılması durumunda; ürün istiflenmesi ile şartlandırılmış hava dağılımı ve sıcaklık rijit olmamaktadır. Evaporatörlerin dar duvarlarda karşılıklı konumlandırılması durumunda, ürün istiflemesinin deponun orta kısmında ve uygun aralıklarda yapılmasının daha uygun olacağı belirlenmiştir. Evaporatör yerleşiminin geniş tek duvarlarda olması, sıcaklığın eşit dağılmasını sağlarken diğer yandan üründe nem kaybına sebep olabilir. Soğuk hava tesisi kurulması esnasında veya mevcut soğuk odalarda, ürün istifleme biçimleri ile hava akımlarının ve sıcaklık dağılımlarının öncelikle CFD analiz programıyla simüle edilmesi, ürün kayıplarında azalma, enerji tasarrufu, zaman ve işletme maliyetinde kazanımlar elde edileceği düşünülmektedir. In this study; The effect of evaporators used in cold storage rooms to distribute cold air to the storage environment on the product losses caused by airflow on temperature and velocity distributions were investigated. The data obtained in the experimental studies were compared by simulating in the CFD program for the same warehouse conditions, and the overlap and usability of the results were determined. In case the evaporator is positioned on a single wall; Air distribution and temperature conditioned by-product stacking are not rigid. It has been determined that if the evaporators are positioned mutually on narrow walls, it would be more appropriate to do the product stacking in the middle of the warehouse and at appropriate intervals. The fact that the evaporator placement is on wide single walls may cause even distribution of the temperature while also causing moisture loss in the product. It is thought that during the establishment of the cold air facility or in the existing cold rooms, product stacking methods and simulating the air flows and temperature distributions with the CFD analysis program, reduction in product losses, energy savings, time, and operating costs will be achieved.

31 August 2025 in Electrical Engineering and Energy (ELENE)
Verified
Journal Article
Open access
PDF file
AAAyse Bilgen Aksoy
Ayse Bilgen Aksoy
FUFatma Nur Uzun
Fatma Nur Uzun
YAYigit Aksoy
Yigit Aksoy
This study numerically investigates the thermal, exergy, and environmental performance of a widely used PCCP-type (Type 22) panel radiator equipped with three newly designed fin geometries using ANSYS-based CFD simulations. The proposed configurations were evaluated and compared with a conventional fin design under identical operating conditions to assess their influence on overall heat transfer performance. The results demonstrate that the I-profile fin achieved the highest performance, delivering a thermal efficiency of 61.9%, an exergy efficiency of 15.8%, and approximately a 33% reduction in CO₂ emissions compared to the standard model. While some alternative designs slightly reduced emissions further, they also resulted in notable exergy losses, highlighting a trade-off between energy quality and environmental benefits. These findings indicate that optimized fin geometries can be seamlessly integrated into existing manufacturing processes with minimal modifications, providing a practical and scalable solution for improving energy efficiency and supporting the development of sustainable radiator designs.

6 June 2022 in Mühendis ve Makina
Verified
Journal Article
Closed access
PDF file
FBFevzi BALKAN
Fevzi BALKAN
AAAyse Bilgen Aksoy
Ayse Bilgen Aksoy
Soğuk hava depoları, gıdaların tazeliklerinin korunması hususunda büyük öneme sahiptir. Gıdaların besin değerlerini koruyabilmeleri, oda havasının doğru sıcaklık ve nemde şartlandırılmasına bağlıdır. Sıcaklık ve nem dengesi evaporatörlerden ortama sağlanan şartlandırılmış hava ile gerçekleştirilir. Bu çalışmada; soğuk hava depolarında, soğuk havanın depo ortamına dağılımını sağlamak amacıyla kullanılan evaporatörlerin odaya yerleşim yerlerinin, sıcaklık ve hız dağılımlarına hava akışının sebep olduğu ürün kayıplarına etkisi incelenmiştir. Deneysel çalışma, içerisinde narenciye bulunan soğuk odada gerçekleştirilmiştir. Deneysel çalışmalarda elde edilen veriler, aynı depo şartları için CFD programında simüle edilerek karşılaştırılmış ve sonuçların örtüştüğü ve kullanılabilirliği belirlenmiştir. Çeşitli evaporatör konumlandırmaları simüle edilerek, sıcaklıkları ve ürün istifleme şartları belirlenmeye çalışılmıştır. Evaporatörün tek duvarda konumlandırılması durumunda; ürün istiflenmesi ile şartlandırılmış hava dağılımı ve sıcaklık rijit olmamaktadır. Evaporatörlerin dar duvarlarda karşılıklı konumlandırılması durumunda, ürün istiflemesinin deponun orta kısmında ve uygun aralıklarda yapılmasının daha uygun olacağı belirlenmiştir. Evaporatör yerleşiminin geniş tek duvarlarda olması, sıcaklığın eşit dağılmasını sağlarken diğer yandan üründe nem kaybına sebep olabilir. Soğuk hava tesisi kurulması esnasında veya mevcut soğuk odalarda, ürün istifleme biçimleri ile hava akımlarının ve sıcaklık dağılımlarının öncelikle CFD analiz programıyla simüle edilmesi, ürün kayıplarında azalma, enerji tasarrufu, zaman ve işletme maliyetinde kazanımlar elde edileceği düşünülmektedir.

25 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAyse Bilgen Aksoy
Ayse Bilgen Aksoy
FUFatma Nur Uzun
Fatma Nur Uzun
FBFevzi BALKAN
Fevzi BALKAN
Corrugated pipes are widely used due to their mechanical flexibility; however, their corrugated internal geometry is associated with increased hydraulic losses. Previous studies have reported a non-classical increase in friction factors with pipe diameter at identical Reynolds numbers, although the underlying mechanisms and related energy implications have not been fully clarified. In this study, turbulent flow behavior and pumping power requirements in stainless-steel corrugated pipes are investigated using a validated three-dimensional Computational Fluid Dynamics (CFD) framework based on the SST k–ω turbulence model. The numerical predictions show good agreement with available experimental data, with maximum deviations remaining below approximately 12% across the validated range. The results indicate that both friction factor and pumping power increase systematically with pipe diameter under dynamically similar flow conditions, demonstrating that Reynolds-number similarity alone does not ensure flow similarity in corrugated geometries. From an energy perspective, an Energy Penalty Factor (EPF) is introduced to quantify corrugation-induced pumping requirements, and a surrogate correlation is developed to relate EPF to Reynolds number and selected dimensionless geometric parameters. The proposed formulation exhibits strong predictive performance within the investigated parameter space (R2 = 0.972) and enables rapid, CFD-free estimation of energy penalties for preliminary design and comparative evaluation of corrugated piping systems.

1 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AAAyse Bilgen Aksoy
Ayse Bilgen Aksoy
This work investigates the performance of a solar air heater (SAH) equipped with ten baffles whose angles can be adjusted in real time by a PLC. Many SAH systems operate passively, which makes their outlet temperature sensitive to daily variations in solar radiation. This study aims to show that an actively controlled SAH can maintain stable and efficient operation under practical outdoor conditions. Experiments were carried out at two set-point temperatures commonly used in drying applications, 54 °C and 60 °C, and the system was assessed through energy, exergy, and sustainability indicators. Greater baffle inclination increased turbulence and heat transfer, yielding thermal efficiencies up to 76.8%. The friction factor followed the Reynolds number closely, indicating that overall flow resistance depends mainly on the airflow rate. Exergy efficiency remained between 1.24% and 2.69%, while the Sustainability Index stayed near unity due to fan power related losses. A regression model was also developed to estimate the airflow needed to keep the outlet temperature at the desired level. Long-term projections show that the system can supply 20–22 MWh of heat and avoid nearly 9 tons of CO₂ emissions over 20 years. These findings highlight that combining PLC-based control with adjustable baffles offers a practical and environmentally meaningful improvement for solar air heating systems.