The advantages of gas-phase synthesis of nanoparticles in terms of size control and flexibility in choice of materials is well known. There is increasing interest in synthesizing multi-element nanoparticles in order to optimize their performance in specific applications, and here, the flexibility of material choice is a key advantage. Mixtures of almost any solid materials can be manufactured and in the case of core–shell particles, there is independent control over core size and shell thickness. This review presents different methods of producing multi-element nanoparticles, including the use of multiple targets, alloy targets and in-line deposition methods to coat pre-formed cores. It also discusses the factors that produce alloy, core–shell or Janus morphologies and what is possible or not to synthesize. Some applications of multi-element nanoparticles in medicine will be described.
Cloth used for facemask material has been coated with silver nanoparticles using an aerosol method that passes pure uncoated nanoparticles through the cloth and deposits them throughout the volume. The particles have been characterized by electron microscopy and have a typical diameter of 4 nm with the atomic structure of pure metallic silver presented as an assortment of single crystals and polycrystals. The particles adhere well to the cloth fibers, and the coating consists of individual nanoparticles at low deposition times, evolving to fully agglomerated assemblies in heavy coatings. The cloth was exposed to Usutu virus and murine norovirus particles in suspension and allowed to dry, following which, the infectious virus particles were rescued by soaking the cloth in culture media. It was found that up to 98% of the virus particles were neutralized by this contact with the silver nanoparticles for optimum deposition conditions. The best performance was obtained with agglomerated films and with polycrystalline nanoparticles. The work indicates that silver nanoparticles embedded in masks can neutralize the majority of virus particles that enter the mask and thus increase the opacity of masks to infectious viruses by up to a factor of 50. In addition, the majority of the virus particles released from the mask after use are non-infectious.
We have characterized the magnetization easy-axis of ultra-thin Co films (2–5 atomic layers, AL) grown on Ru(0001) when they are capped with a monolayer of Pd. The addition of a Pd monolayer turns the magnetization of 3 and 4 AL-thick Co films from an in-plane to an out-of-plane alignment, but not that of a 5 AL-thick film. These observations are explained in terms of an enhancement of the surface anisotropy. The exposure of the sample to hydrogen, CO or a combination of both gases does not overcome this effect.
X-ray Magnetic Circular Dichroism (XMCD) was performed on nanostructured FeCo films prepared by depositing 2.1 nm Co gas phase nanoparticles in conjunction with atomic Fe matrices at different Co concentrations to measure the spin and orbital magnetic moments of the constituents. These films have been shown in previous studies to have a very high saturation magnetisation that exceeds the Slater-Pauling limit of 2.45 µB/atom. In this work we show that, at the optimum concentration, the Fe atoms have a total magnetic moment of, at least 2.64 mB/atom, while the Co atoms show a value of 2.7 mB/atom. From these quantities, the average magnetic moment per atom of the film is shown to agree with the previously reported values. Relative to the bulk values the enhancement of the Co moment is the greatest and the Co spin moment reaches 2.31 µB/atom, which is 77% of the spin polarisation in the free atom. We also show that the enhancement of the orbital magnetic moment of Fe and Co plays a major role in the magnetisation of the samples, these being as high as 0.178 mB/atom. and 0.388 mB/atom. respectively, i.e., twice their bulk values. This work thus confirms the origin of these films’ exceptionally high saturation magnetisation, whose optimum magnetic moments per atom occur at a Co concentration close to the percolation threshold, where there is a maximum proportion of Fe/Co interface.
We present a sustainable laboratory experiment for determining the wavelength of a laser by diffraction from thin cylindrical wires using an experimental setup constructed from recycled household materials. Instead of the conventional single-measurement approach, the activity employs wires of different diameters and determines the wavelength through a linear regression procedure, introducing students to calibration methods and data analysis techniques commonly used in experimental physics. The experiment was designed for introductory undergraduate laboratories and combines wave optics with an authentic measurement strategy while requiring only simple, readily available materials. Its implementation demonstrates that recycled components can support accurate quantitative measurements and provide an effective context for discussing uncertainty, reproducibility and experimental methodology. By integrating sustainability, statistical data analysis and hands-on optics within a single activity, the proposed experiment offers an accessible, low-cost and easily reproducible laboratory exercise that enriches traditional diffraction experiments and promotes a more realistic view of experimental practice.