Sheng Li

Prof. Dr. Sheng Li

Nanjing Institute of Technology, Nanjing, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2023 in Electronics
Verified
Journal Article
Open access
PDF file
SLSheng Li
Sheng Li
TZTianhong Zhang
Tianhong Zhang
JYJiawei Yu
Jiawei Yu
After prolonged operation, external objects may obstruct the photovoltaic (PV) array, resulting in prolonged partial shading. The dynamic reconfiguration of PV arrays uses a switch matrix to change the electrical positions of the PV cells in the array, and it is an effective method to solve the problem of partial shading. Most of the current dynamic reconfigurations only consider the optimization of power output. Neglecting the switch actions will increase the number of switch matrix actions, making the switch control more complex and reducing the lifespan of devices. To address power optimization and switch action optimization simultaneously during dynamic reconfiguration, this paper introduces a novel objective function. This function combines power optimization and switch action optimization in a weighted manner. Based on the novel function, the algorithm prioritizes optimizing the electrical positions of PV cells with larger shading values. This ensures that the PV array can improve its output while significantly reducing the number of switch actions. The Pelican Optimization Algorithm (POA) is improved and employed to optimize the proposed objective function. In terms of the output power optimization, the effectiveness of the novel objective function with the improved POA is validated by comparing and analyzing the reconfiguration results with the conventional objective functions under four shading scenarios. The results demonstrate that the novel objective function with the improved POA increases the output power by 30% in short and wide shadow and achieves the highest power output. Moreover, the tests conducted on dynamic reconfiguration results with different weights validate the effectiveness of the novel objective function in minimizing switching actions while improving power output.

28 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
SLSheng Li
Sheng Li
ZWZhinong Wei
Zhinong Wei
YMYanan Ma
Yanan Ma
Based on the equilibrium point equations of a classic three-node system integrated with a large-scale photovoltaic cell (PV) power plant, the impact of PV output fluctuation on the saddle-node bifurcation (SNB) was derived and analyzed. When PV runs in a unity power factor and the PV output active power Ppv is not too large (several hundred MW and below), the PV output fluctuation has little effect on the SNB point position and load margin index, so that the load margin index can be calculated online using the SNB point at Ppv = 0 pu. On the other hand, the local reactive power compensation in the load center can effectively raise the load bus voltage and make the voltage stability problem become more concealed; the traditional under-voltage load-shedding (UVLS) strategy only carries out load shedding when the bus voltage amplitude is below the specified value and cannot effectively maintain the system static voltage stability in some occasions. In this paper, a fuzzy load-shedding strategy considering the impact of PV output fluctuations for the large-scale PV grid-connected system was designed, taking the load bus voltage amplitude and load margin index as fuzzy input variables, and the load-shedding command as a fuzzy output variable. Nine fuzzy IF-THEN rules were extracted for the fuzzy controller and the corresponding practical calculation method of load-shedding quantity was put forward. The simulation results of the classic three-node system and IEEE 14-bus system, both with a 100 MW PV power plant, verified the effectiveness of the fuzzy load-shedding controller whose input variable load margin index was calculated using the SNB point when the PV active power output was 0. The designed fuzzy load-shedding strategy can compensate for the defect—that the traditional UVLS strategy cannot effectively guarantee the system static voltage stability—and it can be widely used in power grids integrated with PV power plants whose scales are at a level of several hundred MW and below.

24 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YGYuan Gao
Yuan Gao
SLSheng Li
Sheng Li
XYXiangyu Yan
Xiangyu Yan
Distributed photovoltaic (PV) output exhibits strong stochasticity and weak adjustability. After being integrated with the network, its interaction with stochastic loads increases the difficulty of assessing the distribution network’s static voltage stability (SVS). In response to this issue, this article presents a probabilistic assessment method for SVS in a distribution network with distributed PV that considers the bilateral uncertainties and correlations on the source and load sides. The probabilistic models for the uncertain variables are established, with the correlation between stochastic variables described using the Copula function. The three-point estimate method (3PEM) based on the Nataf transformation is used to generate correlated samples. Continuous power flow (CPF) calculations are then performed on these samples to obtain the system’s critical voltage stability state. The distribution curves of critical voltage and load margin index (LMI) are fitted using Cornish-Fisher series. Finally, the utility function is introduced to establish the degree of risk of voltage instability under different scenarios, and the SVS assessment of the distribution network is completed. The IEEE 33-node distribution system is utilized to test the method presented, and the results across various scenarios highlight the method’s effectiveness.

17 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
SLSheng Li
Sheng Li
YLYuting Lu
Yuting Lu
YGYulin Ge
Yulin Ge
The large-scale integration of photovoltaic (PV) power can bring a greatly negative influence on the grid-connected system’s voltage stability. To study the static voltage stability (SVS) of PV grid-connected systems, the traditional SVS index, L-index, was re-examined. It was firstly derived and proved that the PV active output Ppv is proportional to the voltage phase angle of the PV station’s POI (Point of Interconnection), based on a simplified two-node system integrated with a PV station operating in PV (active power—voltage) mode or PQ (active power—reactive power) mode with unit power factor. Then a novel voltage stability sensitivity index LPAS-index was proposed that takes the derivative of the L-index with respect to the POI’s voltage phase angle, so as to reflect the influence degree of Ppv on the SVS of each load node. A SVS zoning analysis method for the PV grid-connected system was designed according to the classification results of load nodes based on the proposed LPAS-index, the power grid can be zoned into three kinds of areas that reflect different correlations between the SVS and Ppv: strong correlation, moderate correlation and weak correlation. Since the LPAS-index is less impacted by Ppv, the SVS zoning results are relatively unchanged. On the basis of a classic 14-node system with PV, the practicability of the zoning analysis method was verified. The simulation results show that the PV access point in general falls within the strongly or moderately associated area with Ppv. When most of the load nodes fall within the weakly associated area with Ppv, it is not necessary to consider the impact of Ppv and load power is still the main influencing factor on the SVS. In the multi-PV case, owing to the expansion of areas more affected by Ppv, an excessive Ppv can cause adverse influence on the SVS of the whole power grid; and an effective PV power-shedding measure is proposed to solve this problem. The proposed SVS zoning analysis method can be used for reference by power grid dispatchers.

19 April 2025 in Information
Verified
Journal Article
Open access
PDF file
SLSheng Li
Sheng Li
天陈天宇 陈
天宇 陈
RDRui Ding
Rui Ding
In the context of rapid advancement of smart cities, a distribution network (DN) serving as the backbone of urban operations is a way to confront multifaceted challenges that demand innovative solutions. Central among these, it is imperative to optimize resource allocation and enhance the efficient utilization of diverse energy sources, with particular emphasis on seamless integration of renewable energy systems into existing infrastructure. At the same time, considering that the traditional power system’s “rigid”, instantaneous, dynamic, and balanced law of electricity, “source-load”, is difficult to adapt to the grid-connection of a high proportion of distributed generations (DGs), the collaborative interaction of multiple flexible controllable resources, like flexible loads, are able to supplement the power system with sufficient “flexibility” to effectively alleviate the uncertainty caused by intermittent fluctuations in new energy. Therefore, an active distribution network (ADN) intraday, reactive, power optimization-scheduling model is designed. The dynamic reactive power collaborative interaction model, considering the integration of DG, energy storage (ES), flexible loads, as well as reactive power compensators into the IEEE 33-node system, is constructed with the goals of reducing intraday network losses, keeping voltage deviations to a minimum throughout the day, and optimizing static voltage stability in an active distribution network. Simulation outcomes for an enhanced IEEE 33-node system show that coordinated operation of source–network–load–storage effectively reduces intraday active power loss, improves voltage regulation capability, and achieves secure and reliable operation under ADN. Therefore, it will contribute to the construction of future smart city power systems to a certain extent.

19 January 2017 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
SLSheng Li
Sheng Li
ZWZhinong Wei
Zhinong Wei
YMYanan Ma
Yanan Ma
JCJielei Cheng
Jielei Cheng
The unstable Hopf bifurcation (UHB) of a power system generally precedes the saddle‐node bifurcation, so the UHB point can be the system critical point of voltage collapse. However, after the large‐scale photovoltaic (PV) power station is connected to the system, the fluctuation characteristic of PV output can lead to the change of UHB point position and the evaluation process of system voltage stability is also affected. Therefore, according to the feature that the UHB point has the minimum value of hopf bifurcation index (HBI) index, a method for predicting the equilibrium HBI value is proposed based on an optimised support vector machine (SVM) algorithm (including particle swarm optimisation SVM and genetic algorithm optimisation SVM). Once the HBI prediction value of the current operating point (the equilibrium point) is less than or equal to the preset HBI alert value, it is possible to take an emergency load‐shedding measure to remove a small amount of load, and the position of UHB point under maximum PV output is used to set the amount of load‐shedding, so the oscillatory collapse of the load bus voltage caused by a sudden increase of PV output or load fluctuation can be avoided. Taking a large‐scale PV power station access to the classic three‐node system as an example, the prediction and control method is verified. Simulation result shows that the method is simple and practical, as well as suitable for on‐line prediction and control of UHB point in a PV grid‐connected system, which is able to improve the prevention and emergency control capability of the system voltage stability.