Brandon Male

Dr. Brandon Male


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
RKRachel Kowal
Rachel Kowal
BABrittney Aldape
Brittney Aldape
BLBrendan Lochbaum
Brendan Lochbaum
BMBrandon Male
Brandon Male
The purpose of this study was to examine the validity of a Garmin wrist-based device for estimating heart rate, energy expenditure, and step count during incremental treadmill exercise in college-aged individuals. Eighteen males and females (mean ± SD age = 23.2 ± 4.9 years) volunteered to complete an incremental treadmill test with the Garmin Vivoactive 4 device and criterion methods (electrocardiogram, indirect calorimetry, and video recording) measuring heart rate, energy expenditure, and step count. Mean absolute percent error (MAPE), simple linear regression, and Bland-Altman plots were used to assess accuracy. Acceptable accuracy was defined as MAPE < 5% for heart rate and < 10% for energy expenditure and step count. Statistical significance was set at α < 0.05. The MAPE (±SD) values were 13.0 (±10.1), 19.1 (±15.0), and 4.6 (±5.3)% for heart rate, energy expenditure, and step count, respectively. The Bland-Altman regression analyses illustrated proportional bias was present for estimations of heart rate (r = 0.591, p < 0.001) and step count (r = 0.516, p = 0.028), but not energy expenditure (r = 0.351, p = 0.153). These findings indicated that the Garmin Vivoactive 4 provided acceptable accuracy metrics for step count, but not heart rate or energy expenditure.

27 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
RKRachel Kowal
Rachel Kowal
BABrittney Aldape
Brittney Aldape
BLBrendan Lochbaum
Brendan Lochbaum
BMBrandon Male
Brandon Male
The purpose of this study was to examine the validity of a Garmin device for estimating heart rate, energy expenditure, and step count during incremental treadmill exercise. Eighteen physically active males (n = 12; mean ± SD age = 22.8 ± 4.7 years; body mass = 83.8 ± 13.4 kg) and females (n = 6; 24.2 ± 5.6 years; 65.2 ± 9.6 kg) completed an incremental treadmill test with the Garmin Vivoactive 4 and criterion methods measuring heart rate, energy expenditure, and step count. Mean absolute percent error (MAPE) and Bland–Altman plots were used to assess accuracy. Acceptable accuracy was defined as MAPE < 5% for heart rate and <10% for energy expenditure and step count. MAPE (±SD) values were 13.0 (±10.1), 19.1 (±15.0), and 4.6 (±5.3)% for heart rate, energy expenditure, and step count, respectively. The Bland–Altman regression analyses illustrated proportional bias was present for heart rate (r = 0.591, p < 0.001) and step count (r = 0.516, p = 0.028), but not energy expenditure (r = 0.351, p = 0.153). These findings indicated that the Garmin Vivoactive 4 provided acceptable accuracy for step count but unacceptable accuracy for heart rate and energy expenditure during incremental treadmill exercise.