Purpose: the purpose of this study was to evaluate the safety and usability of the ATLAS 2030 in children with Cerebral Palsy (CP) and Spinal Muscular Atrophy (SMA). Materials and Methods: the sample consisted of six children, three with CP and three with SMA, who received eight sessions of robot-assisted gait therapy. Safety was measured by the presence of adverse events. Usability was measured by spatiotemporal parameters, the Six-Minute Walking Test (6MWT), and the time needed for donning and doffing, as well as satisfaction questionnaires administered to therapists and patients. Results: no serious adverse events were reported. The average cadence and number of steps per session increased throughout sessions, as well as the distance covered in the 6MWT, both in participants with CP and SMA. The mean donning time at the end of the study was 4.6 ± 1.3 min, and only one therapist was necessary to carry out all of the sessions. Satisfaction was considered high by both children and therapists. Conclusions: the ATLAS 2030 was shown to be safe for children with CP and SMA. The usability of the device was good, since a progression in the spatiotemporal parameters was observed throughout the sessions, and patient and therapist satisfaction were high.
This study explored the effects of a modular overground exoskeleton on plantar pressure distribution in healthy individuals and individuals with Acquired Brain Injury (ABI). The research involved 21 participants, including ABI patients and healthy controls, who used a unique exoskeleton with adaptable modular configurations. The primary objective was to assess how these configurations, along with factors such as muscle strength and spasticity, influenced plantar pressure distribution. The results revealed significant differences in plantar pressures among participants, strongly influenced by the exoskeleton’s modularity. Notably, significant distinctions were found between ABI patients and healthy individuals. Configurations with two modules led to increased pressure in the heel and central metatarsus regions, whereas configurations with four modules exhibited higher pressures in the metatarsus and hallux regions. Future research should focus on refining and customizing rehabilitation technologies to meet the diverse needs of ABI patients, enhancing their potential for functional recovery.
In recent years, the prevalence of acquired brain injury (ABI) has been on the rise, leading to impaired gait functionality in affected individuals. Traditional gait exoskeletons are typically rigid and bilateral and lack adaptability. To address this, the STELO, a pioneering modular gait-assistive device, was developed. This device can be externally configured with joint modules to cater to the diverse impairments of each patient, aiming to enhance adaptability and efficiency. This study aims to assess the safety and usability of the initial functional modular prototype, STELO, in a sample of 14 ABI-diagnosed participants. Adverse events, device adjustment assistance and time, and gait performance were evaluated during three sessions of device use. The results revealed that STELO was safe, with no serious adverse events reported. The need for assistance and time required for device adjustment decreased progressively over the sessions. Although there was no significant improvement in walking speed observed after three sessions of using STELO, participants and therapists reported satisfactory levels of comfort and usability in questionnaires. Overall, this study demonstrates that the STELO modular device offers a safe and adaptable solution for individuals with ABI, with positive user and therapist feedback.