Rationale: Among 3 forms of mercury, elemental mercury vapor presents the highest threat due to its potential to cause acute pneumonitis. The management of acute mercury vapor poisoning remains unclear, particularly in acute lung injury. We present a case of mercury vapor poisoning resulting from the heating of cinnabar, successfully treated with high-dose corticosteroids and chelation therapy, and follow-up over 6 months. Patient concerns: A 47-year-old female patient was admitted to the Emergency Department due to dyspnea, chest tightness, and weakness following cinnabar heating. Diagnoses: Upon admission, she presented with tachypnea and respiratory failure. During the first 5 days, the respiratory failure rapidly progressed, requiring high-flow nasal cannula support, and showed no improvement with broad-spectrum intravenous (IV) antibiotics and 80 mg daily IV methylprednisolone. Total blood and urinary mercury levels were measured to confirm the diagnosis. Interventions: Upon confirmation of acute pneumonitis due to mercury vapor poisoning, the patient was administered high-dose methylprednisolone (500 mg IV per day) and chelation therapy, which led to subsequent improvement. Outcomes: Six months after discharge, the patient completely recovered, as evidenced by chest imaging and pulmonary function tests. Lessons: Heating elemental mercury can cause pneumonitis, leading to acute respiratory failure. A detailed history is crucial for diagnosis. High-dose methylprednisolone should be considered in patients who do not respond to lower doses. Patients should be monitored afterward to detect residual pulmonary fibrotic changes.
Chronic obstructive pulmonary disease (COPD) stands as one of the leading causes of mortality worldwide. Acute exacerbations of COPD (AECOPD) lead to rapid respiratory function decline and worsened disease status. Despite recent studies, the ability of the neutrophil-to-lymphocyte ratio (NLR) to predict outcomes in patients with COPD remains controversial. We investigated the predictive value of NLR for adverse outcomes in hospitalized patients with AECOPD. A retrospective study was conducted at the Department of Pulmonary Medicine, Cho Ray Hospital (Vietnam) from November 2019 to November 2021. The study extracted data from patients diagnosed with AECOPD at discharge and met the inclusion criteria. NLR is calculated by dividing the number of neutrophils by the number of lymphocytes in the peripheral blood test. Adverse outcomes are defined as invasive mechanical ventilation, admission to intensive care unit, or in-hospital mortality. Multivariable regression analysis was conducted to identify variables predicting adverse outcomes. The cutoff, sensitivity, specificity, area under the curve, and receiver operating characteristic of NLR were determined for predicting adverse outcomes. Two hundred eighty-seven patients with AECOPD were included in the final analysis, with a mean age of 70.9, and males comprising 92.7%. The rate of adverse outcomes was 15.7%. Multivariable logistic regression identified reduced consciousness at admission (adjusted odds ratio = 0.08, 95% confidence interval [CI]: 0.02–0.38, P = .001) and high NLR (adjusted odds ratio = 1.17, 95% CI: 1.10–1.24, P < .001) as predictors of adverse outcomes. The receiver operating characteristic of NLR’s predictive value yielded an area under the curve of 0.877 (95% CI: 0.83–0.93). An NLR cutoff of 11.0 predicted adverse outcomes with a sensitivity of 80.0%, specificity of 77.7%, and an odds ratio of 13.9 (95% CI: 6.3–30.7), P < .001. NLR is a simple, routine, and cost-effective tool for predicting adverse outcomes in hospitalized patients with AECOPD. Future studies should evaluate the kinetics of NLR in predicting treatment response in patients with AECOPD.
Introduction and Importance: Electrocution can lead to severe visceral organ damage, including pulmonary injuries. However, isolated electrical-induced pulmonary injury (EIPI) following electric shock remains underreported. This case reports a 33-year-old male who suffered an EIPI after contact with low-voltage electricity and provides a comprehensive literature review to explore the mechanisms, clinical presentation, imaging findings, and treatment of EIPI. Case Presentation: A previously healthy 33-year-old male presented with dyspnea, chest pain, and dry cough following an electrocution while lifting a fallen 220 V wire. Chest imaging revealed diffuse consolidations, ground-glass opacities (GGO), and interlobular septal thickening. Bronchoscopy findings were normal; no infectious pathogens were detected in blood and sputum cultures. The patient was treated with oxygen therapy, antibiotics, and supportive care, achieving full recovery after 9 days of hospitalization. Clinical Discussion: A review of 12 case reports found that pulmonary injuries following electrocution are mostly associated with low-voltage exposure. The most common findings include bilateral lung consolidations, GGO, and diffuse alveolar hemorrhage. The pathophysiology of lung parenchyma involves coagulation necrosis, leading to alveolar hemorrhage. Management includes supportive care, with surgery reserved for cases with extensive necrosis unresponsive to medical treatment. Conclusion: EIPI is a rare but potentially severe consequence of electrocution, often presenting as bilateral lung consolidations and alveolar hemorrhage. Given the variability in presentation and severity, chest imaging should be considered in all cases after electrocution, even in the absence of external injuries. Early recognition and appropriate treatment are essential to ensure favorable outcomes, with surgical intervention considered in selected cases.
Invasive aspergillosis primarily occurs in immunocompromised patients, while skeletal muscle involvement remains an exceptionally uncommon manifestation. S