Hoje Seong

Hoje Seong

Auto-generated profile, based on publicly available information

Hoje Seong


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2018 in Water
Verified
Journal Article
Open access
PDF file
IPInhwan Park
Inhwan Park
HKHyung-Jun Kim
Hyung-Jun Kim
HSHoje Seong
Hoje Seong
DRDong Sop Rhee
Dong Sop Rhee
The maintenance of the performance of sump pumps is important to mitigate flood damage in urban areas and lowlands. However, the air-entraining vortex in the sump leads to undesirable performance degradation. Thus, in this study, the newly designed floating anti-vortex device (F-AVD) was employed in the intake pipe to enhance the efficiency of water intake in the sump by decreasing the surface vortex. The performance of the F-AVD was evaluated from the model experiments, in which the sump model was designed to represent the pump station that operates in Korea. The flow in the sump was measured using the particle image velocimetry (PIV) technique, and the velocity and vorticity distributions were compared both with and without the adoption of the F-AVD. The experimental results indicated that the vortex structures behind the intake pipe were effectively mitigated by installing the F-AVD. The vorticity magnitude behind the intake pipe was reduced in range of 24.8–52.5% after the installation of the F-AVD. However, in the case of a flow rate increase, the efficiency of the F-AVD decreased because of the strong vortex. Thus, an additional anti-vortex device (AVD), which is attached to the backwall or the floor in the sump, is required to prevent the air entrainment in conditions with high flow rates.

1 November 2018 in Water
Verified
Journal Article
Open access
PDF file
IPInhwan Park
Inhwan Park
HSHoje Seong
Hoje Seong
YRYonguk Ryu
Yonguk Ryu
DRDong Sop Rhee
Dong Sop Rhee
Subway station platforms are vulnerable to flood damage. Thus, investigation of inundation properties in subway platforms is required to ensure the safety of citizens against flooding. In this study, the evacuation time and safety were analyzed in a subway station model using inundation depth measurements. The subway station model contained shallow water depth conditions, which did not allow for contact-type measurement devices. Instead, an image analysis procedure using laser images was proposed to measure the inundation depth. The proposed laser image analysis method can recognize a boundary line between the water and air by visualizing the water surface using a laser sheet. The inundation depth measurements using the image analysis method were reasonably accurate, resulting in differences of 2.97–7.67% compared to the results obtained using a digital point gauge. When inflow positions and flowrates of rainwater were changed, the measured results showed that the inundation depth increased in areas in which the rainwater inflow was relatively small or collided when moving in the direction opposite to the rainwater. The calculated evacuation time from the subway station showed that a drainage system is required to decrease the inundation depth in areas of inflowing rainwater collision. Furthermore, the estimated results of evacuation safety showed that safety handles are necessary even in low depth regions to prevent people from falling down due to increased flow velocity, during evacuation.

9 February 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HSHoje Seong
Hoje Seong
DRDong Sop Rhee
Dong Sop Rhee
IPInhwan Park
Inhwan Park
An urban flood in the Sadang area located in South Korea was reproduced using a rainfall simulator. The rainfall simulator was developed to be able to demonstrate the rainfall intensity in range of 80–200 mm/h, and the artificial rainfall was created using 42 full cone type nozzles in the urban model. The uniformity coefficient of the rainfall distribution was 89.5%, which indicates the rainfall simulator achieved the high requirements for spatial uniformity. The flood experiments in the 1/200 scale model of the Sadang area were conducted using the rainfall simulator, and the flood patterns were investigated by changing the rainfall intensity. The rainwater mainly accumulated in the lowland of the crossroad where the entrances to the subway station are located. The flow velocity and the inundation depth were sharply increased until the rainfall intensity became 160 mm/h. Furthermore, the unstable human activities based on the moment and the friction instabilities also occurred from 160 mm/h. These results suggest that the study area requires flood damage mitigation facilities considering a rainfall intensity exceeding 160 mm/h.

16 December 2020 in Water
Verified
Journal Article
Open access
PDF file
IPInhwan Park
Inhwan Park
JSJaehyun Shin
Jaehyun Shin
HSHoje Seong
Hoje Seong
DRDong Sop Rhee
Dong Sop Rhee
In this study, two types of particle tracking models were presented to investigate the applicability in the two-dimensional solute mixing simulations. The conventional particle tracking model, denoted as PTM, was developed based on Fick’s law, which adopted the dispersion coefficient to calculate the random displacements. The other model is the particle dispersion model (PDM), which computes the shear dispersion process by dividing into two computation procedures as the shear translation and the vertical mixing. The PTM and the PDM included the effects of vertical profiles of velocity in the computation of dispersion coefficients and the shear translation step, respectively. The main difference between the two models is whether the shear dispersion process is reproduced using Fick’s law or the direct computation method. These differences were clearly revealed by comparing with the analytic solution of the advection-dispersion equation. The concentration curve resulting from the PTM shows the Gaussian curves, which were well-fitted with the analytic solution in both initial and Taylor periods. Meanwhile, the PDM presented skewed curves in the initial period and gradually turned to the symmetric shape in the Taylor period. The inherent differences of the two particle tracking models were scrutinized against the two-dimensional tracer test results, which show the non-Fickian mixing properties. The comparisons of concentration–time curves reveal that the PDM reproduced a more accurate shape of the curves than the results by the PTM by demonstrating skewed concentration curves.