The existence of impervious areas is one of the most distinguishing characteristics of urban catchments. They decrease infiltration and increase direct runoff in urban catchments. The recent introduction of green infrastructure in urban catchments for the purpose of sustainable development has contributed to the decrease in directly connected impervious areas (DCIA) by isolating existing impervious areas, and consequently, has also contributed to flood risk mitigation. This study coupled the width function-based instantaneous hydrograph (WFIUH), which is able to handle the spatial distribution of the impervious areas, with the concept of the DCIA to assess the impact of decreasing DCIA on the shape of direct runoff hydrographs. Using several scenarios for typical green infrastructure and the corresponding changes of DCIA for a test catchment in Seoul, South Korea, this study evaluated the effect of green infrastructure on the shape of the resulting direct runoff hydrographs and reducing peak flows. The results showed that the changes in the DCIA immediately affect the shape of the direct runoff hydrograph, and decrease peak flows by up to 12% depending on spatial implementation scenarios in the test catchment. This study demonstrates the importance of the DCIA concept for the evaluation of green infrastructures in urban catchments, enabling quantitative assessment of the spatial distribution of impervious areas, and also changes to the DCIA by various types of green infrastructure. The results of this study also suggest that more effective and well-planned green infrastructures could be introduced in urban environments for the purpose of flood risk management.
The maintenance of the performance of sump pumps is important to mitigate flood damage in urban areas and lowlands. However, the air-entraining vortex in the sump leads to undesirable performance degradation. Thus, in this study, the newly designed floating anti-vortex device (F-AVD) was employed in the intake pipe to enhance the efficiency of water intake in the sump by decreasing the surface vortex. The performance of the F-AVD was evaluated from the model experiments, in which the sump model was designed to represent the pump station that operates in Korea. The flow in the sump was measured using the particle image velocimetry (PIV) technique, and the velocity and vorticity distributions were compared both with and without the adoption of the F-AVD. The experimental results indicated that the vortex structures behind the intake pipe were effectively mitigated by installing the F-AVD. The vorticity magnitude behind the intake pipe was reduced in range of 24.8–52.5% after the installation of the F-AVD. However, in the case of a flow rate increase, the efficiency of the F-AVD decreased because of the strong vortex. Thus, an additional anti-vortex device (AVD), which is attached to the backwall or the floor in the sump, is required to prevent the air entrainment in conditions with high flow rates.
Extreme rainfall causes surface runoff to flow towards lowlands and subterranean facilities, such as subway stations and buildings with underground spaces in densely packed urban areas. These facilities and areas are therefore vulnerable to catastrophic submergence. However, flood modeling of underground space has not yet been adequately studied because there are difficulties in reproducing the associated multiple horizontal layers connected with staircases or elevators. This study proposes a convenient approach to simulate underground inundation when two layers are connected. The main facet of this approach is to compute the flow flux passing through staircases in an upper layer and to transfer the equivalent quantity to a lower layer. This is defined as the ‘adaptive transfer method’. This method overcomes the limitations of 2D modeling by introducing layers connecting concepts to prevent large variations in mesh sizes caused by complicated underlying obstacles or local details. Consequently, this study aims to contribute to the numerical analysis of flow in inundated underground spaces with multiple floors.
Climate change has increased the damage caused by subtropical rainfall and typhoons in coastal areas. Major flooding factors in coastal areas can be classified as storm surges, river inundation, and inland submergence. Because previous studies usually applied a linear sum of individual inundation components to predict comprehensive flood phenomena, this approach does not consider weighted effects associated with the simultaneous occurrence of complex flooding. In this study, a series of comprehensive flood simulations were performed using two numerical models: HDM-2D and FLUval Modeling ENgine (FLUMEN). The results revealed that an integrated flood analysis considering the effects of inundation flooding, river flooding, and coastal flooding required evaluation of the risk of flooding in coastal cities.
A pump station is a crucial flood control facility for mitigating inundation of urban lowland areas. Securing a site to increase the capacity of a pump station or to maximize the discharge capacity of the pump sump in an urban area is difficult because of various limitations. Moreover, adding a facility to improve the pump capacity of a pump station may affect flow characteristics, e.g., unexpected increases in flow velocity and vorticity, and cause severe problems in pump station operation. To solve those problems, anti-vortex devices (AVDs) have been developed and adopted according to the appropriate design standards. The Korean design criteria for AVDs are based on experience and the standards of other countries because of the lack of adequate data on AVDs. In this study, flow in the sump was numerically simulated at various AVD heights to obtain data for improving the design and efficiency of a pump station. Consequently, the appropriate height for the AVD and changes in the flow pattern and vortex in the pump sump were determined and compared with 12 cases of inflow conditions with respect to the vertical location.