Alexander Cherny

Dr. Alexander Cherny

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2021 in Traumatology and Orthopedics of Russia
Verified
Journal Article
Open access
PDF file
ASAndrei P. Sereda
Andrei P. Sereda
AKAndrei A. Kochish
Andrei A. Kochish
ACAlexander Cherny
Alexander Cherny
AAAlexander P. Antipov
Alexander P. Antipov
AAAlimuad G. Aliev
Alimuad G. Aliev
ВНВоронцова Татьяна Николаевна
Воронцова Татьяна Николаевна
Background. Since there is no national arthroplasty registry in the Russian Federation, the exact number of arthroplasty operations performed is unknown. Aim of the study to evaluate the epidemiology of primary, revision hip and knee arthroplasty and periprosthetic joint infection in Russian Federation. Materials and Methods. The inquires were made to 85 subjects, 73 federal state budget institutions and 30 private hospitals. Results. Answers were received from 76 subjects of Russian Federation, 41 federal and 18 private hospitals. The studied indicators revealed to be pretty much heterogenic. The decrease of operations number from 20% to 40% in subjects of Russian Federation due to SARS-CoV-2 pandemic forced us to make no analysis for these 2020 indicators in Russian Federation generally. 147 061 primary hip and knee arthroplasties were performed in 2019 in Russian Federaion. 7 770 revison hip and knee arthroplasties were done. 6 606 cases of severe orthopaedic implant-assosiated infection were cured including 4 282 cases post hip and knee arthroplasties that constitutes 2,91 % from primary arthroplasties. Conclusions. The frequency of periprosthetic joint infection in Russian Federation correlates to the world data. High complexity for patients routing with implant-assosiated infection and strong demand for Federal Center of implant-assosiated orthopaedic infection are revealed.

13 November 2023 in Journal of Orthopaedics
Verified
Journal Article
Closed access
ASAndrei P. Sereda
Andrei P. Sereda
ARAnna N. Rukina
Anna N. Rukina
YTYulia V. Trusova
Yulia V. Trusova
ADAlisagib A. Dzhavadov
Alisagib A. Dzhavadov
ACAlexander Cherny
Alexander Cherny
RTRashid M. Tikhilov
Rashid M. Tikhilov

15 July 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
ACAlexander Cherny
Alexander Cherny
AKAnton N. Kovalenko
Anton N. Kovalenko
TKTaras A. Kulyaba
Taras A. Kulyaba
NKNikolai N. Kornilov
Nikolai N. Kornilov

14 July 2019 in Traumatology and Orthopedics of Russia
Verified
Journal Article
Open access
ACAlexander Cherny
Alexander Cherny
AKA. N. Kovalenko
A. N. Kovalenko
SBS. S. Bilyk
S. S. Bilyk
ADA. O. Denisov
A. O. Denisov
AKA. V. Kazemirskiy
A. V. Kazemirskiy
NKN. N. Kornilov
N. N. Kornilov
The aim of this study was the assessment of early outcomes of patient-specific three-dimensional titanium cones with specified porosity parameters to compensate for extensive metaphysical-diaphyseal bone defects in RTKA.Materials and Methods. Since 2017 till 2019 30 patient-specific titanium cones (12 femoral and 18 tibial) implanted during 26 RTKAS. Clinical outcomes evaluated using KSS, WOMAC and fjS-12 scoring systems on average 10 (2–18) months after surgery. At the same time the stability of implant fixation analyzed using frontal, lateral and axial knee roentgenograms.Results. During all procedures there were no technical difficulties in positioning and implantation of custom-made titanium cones. At the time of preparation of the publication, none of the patients had indications for further surgical intervention, as well as intra- and postoperative complications. Six months after surgery all scores improved significantly: KSS from 23 (2–42, SD 19.96) to 66.5 (62–78, SD 7.68), WOMAC from 59 (56–96, SD 28.31) to 32.25 (19–46, SD 11.76), the index FJS-12 was 29.16 points (0–68.75, SD 30.19). The average scores continued to improve up to 18 months: KSS — 97.5 (88–108, SD 9.14), WOMAC — 16.5 (9–24, SD 6.45), FJS-12 — 45.85 (25–75, SD 22.03). No radiolucent lines were noticed during this period of observation.Conclusion. The original additive technology of designing and producing patient-specific titanium cones for compensation of extensive metaphyseal-diaphyseal bone defects in RTKA is a valid solution at least in the short term. A longer follow-up period is required to assess its medium-and long-term reliability compared to existing alternative surgical solutions.

4 July 2024 in Traumatology and Orthopedics of Russia
Verified
Journal Article
Open access
PDF file
ASAndrei P. Sereda
Andrei P. Sereda
ADAlisagib A. Dzhavadov
Alisagib A. Dzhavadov
ACAlexander Cherny
Alexander Cherny
ЧАЧерный Александр Андреевич
Черный Александр Андреевич
Background. In recent years, the topic of artificial intelligence (AI) in medicine has been actively discussed not just as a promising solution but the one that can help to improve some results. A significant growth of interest in AI systems all over the world began in the early-mid 2010s, which allowed us to consider the practical application of such systems. The aim of the study is to analyze all the software products (SP) registered in our country as a medical device, including those with AI technology, and to evaluate their applicability in traumatology and orthopedics. Methods. The study included all the SP having a registration certificate of a medical device according to the OKPD2 code 58.29.XX.XXX (services for publishing other software). In the state register of medical devices and organizations (individual entrepreneurs), which is engaged in the production and manufacturing of medical devices, we found 111 registered SP according to the inclusion criterion, as at February 14, 2024. Results. We proposed to categorize all registered SP as follows: systems working with the DICOM standard images (47 pcs, 42%), laboratory data (20 pcs, 18%), microscopy images (7 pcs, 6%), photographic images (5 pcs, 5%), medical information systems (4 pcs, 4%), text data mining systems (3 pcs, 3%), clinical decision support systems (3 pcs, 3%), Holter ECG analysis (2 pcs, 2%), other systems (16 pcs, 14%). Systems applicable to traumatology and orthopedics accounted for 4 pcs (4%). Conclusions. Unfortunately, the real-world applicability of existing solutions in the field of traumatology and orthopedics can be regarded as minimal in comparison with pulmonology, oncology, and laboratory diagnostics, where AI programs have already achieved significant success.

1 June 2026 in Biomaterials Connect
Verified
Journal Article
Open access
PDF file
APAndrey Pavlychev
Andrey Pavlychev
XBXenia Brykalova
Xenia Brykalova
AKAleksei Konashuk
Aleksei Konashuk
ACAlexander Cherny
Alexander Cherny
AKAnatolii Korneev
Anatolii Korneev
A quantitative assessment of internal electrostatic fields in bone tissue is conducted within the framework of the “bone-battery” concept. It is shown that their influence on the atomic structure and dynamics is significantly underestimated. To test this hypothesis Raman spectroscopy is applied to cortical bone of young and mature rats. Particular attention is paid to the v1(PO43-)-band at 960 cm-1 in the Raman spectra to study the interference of P - O stretching with the dipole polarization of PO43- ions in the electrostatic fields. The v1(PO43-)-band is found split into the bulk and interface components with predominant Gaussian and Lorentzian shapes respectively. Their formation is a subject of site- and age-dependent dipoles polarization at the surface of nanocrystals. Based on the experimental and theoretical results, both the memory effect during the mineralization of bioapatite nanocrystals and quantum effects associated with low-dimensional quantization of valence states in hydrated nanolayers are predicted, and the prospects for the development of bone tissue engineering at the nanoscale are considered.