Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
Spatiotemporal compression of ultrashort pulses is one of the key issues of chirped pulse amplification (CPA), the most common method to achieve high intensity laser beams. Successful shaping of the temporal envelope and recombination of the spectral components of the broadband pulses need careful alignment of the stretcher-compressor stages. Pulse parameters are required to be measured at the target as well. Several diagnostic techniques have been developed so far for the characterization of ultrashort pulses. Some of these methods utilize nonlinear optical processes, while others based on purely linear optics, in most cases, combined with spectrally resolving device. The goal of this work is to provide a review on the capabilities and limitations of the latter category of the ultrafast diagnostical methods. We feel that the importance of these powerful, easy-to-align, high-precision techniques needs to be emphasized, since their use could gradually improve the efficiency of different CPA systems. We give a general description on the background of spectrally resolved linear interferometry and demonstrate various schematic experimental layouts for the detection of material dispersion, angular dispersion and carrier-envelope phase drift. Precision estimations and discussion of potential applications are also provided.
The temporal contrast is classified into two main regimes, the nanosecond-scale and the picosecond-scale contrast prior to the main pulse. The Lund terawatt laser system is shown to be improved on the nano- and picosecond-scale by a factor of 10 and 50, respectively, when it was optimized for contrast but not for energy. Calculations are also presented to emphasize the role of angular dispersion on the picosecond contrast. Finally we show a compromise between the duration and contrast of femtosecond laser pulses amplified in an optical parametric (chirped pulse) amplifier.
1 April 2024 in High Power Laser Science and Engineering
A colliding microjet liquid sheet target system was developed and tested for pairs of round nozzles of 10, 11 and 18 μm in diameter. The sheet’s position stability was found to be better than a few micrometers. Upon interaction with 50 mJ laser pulses, the 18 μm jet has a resonance amplitude of 16 μm at a repetition rate of 33 Hz, while towards 100 Hz it converges to 10 μm for all nozzles. A white-light interferometric system was developed to measure the liquid sheet thickness in the target chamber both in air and in vacuum, with a measurement range of 182 nm–1 μm and an accuracy of ±3%. The overall shape and 3D shape of the sheet follow the Hasson–Peck model in air. In vacuum versus air, the sheet gradually loses 10% of its thickness, so the thinnest sheet achieved was below 200 nm at a vacuum level of 10–4 mbar, and remained stable for several hours of operation.
Spatial characterization of 0.5 MeV proton beam, driven by 12 fs, 35 mJ, 1019 W/cm2 intense laser-foil interaction is presented. The accelerated proton beam has been applied to obtain a high-resolution, point-projection static radiograph of a fine mesh using a CR-39 plate. The reconstruction of mesh edge blurring and particle ray tracing suggests that these protons have an effective source size (FWHM) of just 3.3 ± 0.3 µm. Furthermore, the spatial distribution of the proton beam recorded on the CR-39 showed that the divergence of these particles is less than 5-degree (FWHM). The low divergence and small source size of the proton beam resulted in an ultralow transverse emittance of 0.00032 π-mm-mrad, which is several orders of magnitude smaller than that of a conventional accelerator beam.