Robabeh Rahimi

Dr. Robabeh Rahimi

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
RRRobabeh Rahimi
Robabeh Rahimi
MTMichael Taylor
Michael Taylor
XLXing Li
Xing Li
KCKuan Ling Chen
Kuan Ling Chen
GMGrayden MacLennan
Grayden MacLennan
DKDaniel Kim
Daniel Kim
Purpose: The treatment of brain tumors in pregnant patients poses challenges, as the out‐of‐field dose exposure to the fetus can potentially be harmful. A pregnant patient with prior radiation treatment was presented with a brain tumor at our clinic. This work reports on our pre‐treatment study that compared fetal dose exposure between intensity‐modulated proton therapy (IMPT) using pencil beam scanning (PBS) and conventional photon 3D conformal radiation therapy (3DCRT) and volumetric‐modulated arc therapy (VMAT), and the subsequent pregnant patient's radiation treatment.Materials and methods: Pre‐treatment measurements of clinical plans, 3DCRT, VMAT, and IMPT, were conducted on a phantom. Measurements were performed using a device capable of neutron detections, closely following AAPM guidelines, TG158. For photon measurements, fetus shielding was utilized. On patient treatment days, which was determined to be proton treatment, shielding was used only during daily imaging for patient setup. Additionally, an in vivo measurement was conducted on the patient.Results: Measurements showed that IMPT delivered the lowest fetal dose, considering both photon and neutron out‐of‐field doses to the fetus, even when shielding was implemented for photon measurements. Additionally, the proton plans demonstrated superior treatment for the mother, a reirradiation case.Conclusion: The patient was treated with proton therapy, and the baby was subsequently delivered at full term with no complications. This case study supports previous clinical findings and advocates for the expanded use of proton therapy in this patient population.

28 September 2015 in Quantum Information Processing
Verified
Journal Article
Closed access
PDF file
HMHosein Mohammadzadeh
Hosein Mohammadzadeh
ZEZahra Ebadi
Zahra Ebadi
HMHossein Mehri-Dehnavi
Hossein Mehri-Dehnavi
BMBehrouz Mirza
Behrouz Mirza
RRRobabeh Rahimi
Robabeh Rahimi

7 January 2015 in Quantum Information Processing
Verified
Journal Article
Closed access
PDF file
HMHossein Mehri-Dehnavi
Hossein Mehri-Dehnavi
RRRobabeh Rahimi
Robabeh Rahimi
HMHosein Mohammadzadeh
Hosein Mohammadzadeh
ZEZahra Ebadi
Zahra Ebadi
BMBehrouz Mirza
Behrouz Mirza

6 November 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
RKRao Khan
Rao Khan
RRRobabeh Rahimi
Robabeh Rahimi
JFJiajin Fan
Jiajin Fan
KCKuan Ling Chen
Kuan Ling Chen
Objective. We aim to characterize kinetics of radiation-induced optical density in newly released EBT4 radiochromic films exposed to clinical x-rays. Several film models and batches were evaluated for the film sensitivity, optical signal increasing with time, relative film noise, and minimum detectable limits (MDL). Approach. Radiochromic film pieces from a single batch of EBT3 and three batches of EBT4 were exposed to doses of 77.38 cGy, 386.92 cGy, and 773.84 cGy using a 6 MV x-ray beam. The films were scanned with a flatbed scanner at specific time intervals up to 120 h. The time-series net optical density of red, green and blue colors was corrected for response of the scanner with time and studied to establish the saturation characteristics of film polymerization process. Dose–response from 3.86 cGy to 1935 cGy was also determined for each color. MDL of the films was quantitatively defined as the dose that would double the net optical density of red color above the standard deviation of the residual signal at zero dose. The relative noise characteristics of EBT3 versus EBT4 were studied as a function of time, dose and scanner resolution. Main Results. For doses ≥ 100 cGy, analysis revealed a stability of optical density beyond 48 h post-exposure for EBT3 and EBT4 films. EBT3 films attained 80%-90% of their net optical density at 48 h within minutes of irradiation, compared to 72%-88% for EBT4 films. The rate of growth was slowest for blue color, fastest for red, while green was in between the two. The MDL for EBT4 averaged 15 cGy for three batches, whereas EBT3 films reliably detected doses as low as 8.5 cGy. Significance. Several batches of the new EBT4 film showed slightly lower response compared to its predecessor over 3.86 cGy to 1935 Gy range. For all practical purposes, the post-irradiation growth of polymers ceases between 48 to 60 h for both EBT films. Overall, the EBT4 film exhibited noise characteristics similar to EBT3, except for lower doses where the noise was observed to be higher than its predecessor.

18 October 2022 in Brachytherapy
Verified
Journal Article
Closed access
XLXing Li
Xing Li
JHJessica Huang
Jessica Huang
RRRobabeh Rahimi
Robabeh Rahimi
HZHui Zhao
Hui Zhao
JKJeremy Kunz
Jeremy Kunz
FSFan-Chi Su
Fan-Chi Su

13 October 2016
Verified
Book Chapter
Closed access
PDF file
RRRobabeh Rahimi
Robabeh Rahimi
KSKazunobu Sato
Kazunobu Sato
PCPatrick Carl
Patrick Carl
PHPeter Höfer
Peter Höfer
RLRaymond Laflamme
Raymond Laflamme
TTTakeji Takui
Takeji Takui