Farhan Siddiqui

Mr. Farhan Siddiqui


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2019 in Diagnostics
Verified
Journal Article
Open access
PDF file
Zeeshan KhanZeeshan Khan
Zeeshan Khan
FSFarhan Siddiqui
Farhan Siddiqui
SPSeungkyung Park
Seungkyung Park
Antibiotic susceptibility testing (AST) specifies effective antibiotic dosage and formulates a profile of empirical therapy for the proper management of an individual patient’s health against deadly infections. Therefore, rapid diagnostic plays a pivotal role in the treatment of bacterial infection. In this article, the authors review the socio-economic burden and emergence of antibiotic resistance. An overview of the phenotypic, genotypic, and emerging techniques for AST has been provided and discussed, highlighting the advantages and limitations of each. The historical perspective on conventional methods that have paved the way for modern AST like disk diffusion, Epsilometer test (Etest), and microdilution, is presented. Several emerging methods, such as microfluidic-based optical and electrochemical AST have been critically evaluated. Finally, the challenges related with AST and its outlook in the future are presented.

12 December 2018 in Biotechnology Letters
Verified
Journal Article
Closed access
PDF file
Zeeshan KhanZeeshan Khan
Zeeshan Khan
FSFarhan Siddiqui
Farhan Siddiqui
SPSeungkyung Park
Seungkyung Park

4 March 2018 in Sensors
Verified
Journal Article
Open access
PDF file
FSFarhan Siddiqui
Farhan Siddiqui
SKSoocheol Kim
Soocheol Kim
HJHyoil Jeon
Hyoil Jeon
TKTaeho Kim
Taeho Kim
CJChulmin Joo
Chulmin Joo
SPSeungkyung Park
Seungkyung Park
Conventional methods for analyzing heavy metal contamination in soil and water generally require laboratory equipped instruments, complex procedures, skilled personnel and a significant amount of time. With the advancement in computing and multitasking performances, smartphone-based sensors potentially allow the transition of the laboratory-based analytical processes to field applicable, simple methods. In the present work, we demonstrate the novel miniaturized setup for simultaneous sample preparation and smartphone-based optical sensing of arsenic As(III) in the contaminated soil. Colorimetric detection protocol utilizing aptamers, gold nanoparticles and NaCl have been optimized and tested on the PDMS-chip to obtain the high sensitivity with the limit of detection of 0.71 ppm (in the sample) and a correlation coefficient of 0.98. The performance of the device is further demonstrated through the comparative analysis of arsenic-spiked soil samples with standard laboratory method, and a good agreement with a correlation coefficient of 0.9917 and the average difference of 0.37 ppm, are experimentally achieved. With the android application on the device to run the experiment, the whole process from sample preparation to detection is completed within 3 hours without the necessity of skilled personnel. The approximate cost of setup is estimated around 1 USD, weight 55 g. Therefore, the presented method offers the simple, rapid, portable and cost-effective means for onsite sensing of arsenic in soil. Combined with the geometric information inside the smartphones, the system will allow the monitoring of the contamination status of soils in a nation-wide manner.