Yoshitake Yamada

Yoshitake Yamada

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2015 in Circulation Research
Verified
Journal Article
Closed access
AAAtsushi Anzai
Atsushi Anzai
MSMasayuki Shimoda
Masayuki Shimoda
JEJin Endo
Jin Endo
TKTakashi Kohno
Takashi Kohno
YKYoshinori Katsumata
Yoshinori Katsumata
MSMotoaki Sano
Motoaki Sano
Rationale:: In-hospital outcomes are generally acceptable in patients with type B dissection; however, some patients present with undesirable complications, such as aortic expansion and rupture. Excessive inflammation is an independent predictor of adverse clinical outcomes. Objective:: We have investigated the underlying mechanisms of catastrophic complications after acute aortic dissection (AAD) in mice. Methods and Results:: When angiotensin II was administered in lysyl oxidase inhibitor–preconditioned mice, AAD emerged within 24 hours. The dissection was initiated at the proximal site of the descending thoracic aorta and propagated distally into an abdominal site. Dissection of the aorta caused dilatation, and ≈70% of the mice died of aortic rupture. AAD triggered CXCL1 and granulocyte-colony stimulating factor expression in the tunica adventitia of the dissected aorta, leading to elevation of circulating CXCL1/granulocyte-colony stimulating factor levels. Bone marrow CXCL12 was reduced. These chemokine changes facilitated neutrophil egress from bone marrow and infiltration into the aortic adventitia. Interference of CXCL1 function using an anti-CXCR2 antibody reduced neutrophil accumulation and limited aortic rupture post AAD. The tunica adventitia of the expanded dissected aorta demonstrated high levels of interleukin-6 (IL-6) expression. Neutrophils were the major sources of IL-6, and CXCR2 neutralization significantly reduced local and systemic levels of IL-6. Furthermore, disruption of IL-6 effectively suppressed dilatation and rupture of the dissected aorta without any influence on the incidence of AAD and neutrophil mobilization. Conclusions:: Adventitial CXCL1/granulocyte-colony stimulating factor expression in response to AAD triggers local neutrophil recruitment and activation. This leads to adventitial inflammation via IL-6 and results in aortic expansion and rupture.

1 January 2017 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
RYRyo Yanagisawa
Ryo Yanagisawa
KHKentaro Hayashida
Kentaro Hayashida
YYYoshitake Yamada
Yoshitake Yamada
MTMakoto Tanaka
Makoto Tanaka
FYFumiaki Yashima
Fumiaki Yashima
KFKeiichi Fukuda
Keiichi Fukuda

1 December 2012 in European Journal of Radiology
Verified
Journal Article
Closed access
YYYoshitake Yamada
Yoshitake Yamada
MJMasahiro Jinzaki
Masahiro Jinzaki
THTakahiro Hosokawa
Takahiro Hosokawa
YTYutaka Tanami
Yutaka Tanami
HSHiroaki Sugiura
Hiroaki Sugiura
SKSachio Kuribayashi
Sachio Kuribayashi

1 August 2012 in Investigative Radiology
Verified
Journal Article
Closed access
YYYoshitake Yamada
Yoshitake Yamada
MJMasahiro Jinzaki
Masahiro Jinzaki
YTYutaka Tanami
Yutaka Tanami
ESEisuke Shiomi
Eisuke Shiomi
HSHiroaki Sugiura
Hiroaki Sugiura
SKSachio Kuribayashi
Sachio Kuribayashi
The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. The institutional review board approved this study, and all patients provided written informed consent. Fifty-two patients underwent low-dose computed tomography (LDCT) (screening-dose, 50 mAs) and ULDCT (4 mAs) of the lung simultaneously. The LDCT images were reconstructed with filtered back projection (LDCT-FBP images) and ULDCT images were reconstructed with both MBIR (ULDCT-MBIR images) and FBP (ULDCT-FBP images). On all the 156 image series, objective image noise was measured in the thoracic aorta, and 2 blinded radiologists independently assessed subjective image quality. Another 2 blinded radiologists independently evaluated the ULDCT-MBIR and ULDCT-FBP images for the presence of noncalcified and calcified pulmonary nodules; LDCT-FBP images served as the reference. Paired t test, Wilcoxon signed rank sum test, and free-response receiver-operating characteristic analysis were used for statistical analysis of the data. Compared with LDCT-FBP and ULDCT-FBP, ULDCT-MBIR had significantly reduced objective noise (both P <; 0.001). Subjective noise on the ULDCT-MBIR images was comparable with that on the LDCT-FBP images but lower than that on the ULDCT-FBP images (P <; 0.001). Artifacts on ULDCT-MBIR images were more numerous than those on the LDCT-FBP images (P = 0.007) but fewer than those on the ULDCT-FBP images (P <; 0.001). Compared with the LDCT-FBP images, ULDCT-MBIR and ULDCT-FBP images showed reduced image sharpness (both P <; 0.001). All the ULDCT-MBIR images showed a blotchy pixelated appearance; however, the performance of ULDCT-MBIR was significantly superior to that of ULDCT-FBP for the detection of noncalcified pulmonary nodules (P = 0.002). The average true-positive fractions for significantly sized noncalcified nodules (≥4 mm) and small noncalcified nodules (<;4 mm) on the ULDCT-MBIR images were 0.944 and 0.884, respectively, when LDCT-FBP images were used as reference. All of the calcified nodules were detected by both the observers on both the ULDCT-MBIR and ULDCT-FBP images. As compared with FBP, MBIR enables significant reduction of the image noise and artifacts and also better detection of noncalcified pulmonary nodules on ULDCT of the lung. Compared with LDCT-FBP images, ULDCT-MBIR images showed significantly reduced objective noise and comparable subjective image noise. Almost all of the noncalcified nodules and all of the calcified nodules could be detected on the ULDCT-MBIR images, when LDCT-FBP images were used as the reference.

1 May 2012 in Investigative Radiology
Verified
Journal Article
Closed access
YYYoshitake Yamada
Yoshitake Yamada
MJMasahiro Jinzaki
Masahiro Jinzaki
YTYutaka Tanami
Yutaka Tanami
TATakayuki Abe
Takayuki Abe
SKSachio Kuribayashi
Sachio Kuribayashi
The purpose of this study was to select the optimal monochromatic level for virtual monochromatic spectral (VMS) imaging to minimize the image noise of the liver parenchyma and to acquire a high contrast-to-noise ratio (CNR) of hypovascular hepatic metastases in the portal-dominant phase. This study was conducted with the approval of our institutional review board, and written informed consent was obtained from all the participating patients. Ninety patients with hepatic metastases were scanned by fast kilovoltage switching dual-energy computed tomography in the portal-dominant phase. One hundred one sets of VMS images in the range of 40 to 140 keV at 1-keV intervals were reconstructed. The image noise of the liver parenchyma in each patient and the CNR of each metastasis (n = 303) were measured on all the 101 VMS image sets. Data were analyzed by the paired t test and mixed-effects model. Bonferroni's method was used for multiple comparisons. The lowest noise of the liver parenchyma was obtained in 6, 15, 31, 29, 7, 1, and 1 patient at 67, 68, 69, 70, 71, 72, and 73 keV, respectively. The mean noise of the liver parenchyma on the 69-keV VMS images in all 90 patients was significantly lower than that on the 67-, 68-, 71-, 72-, and 73-keV VMS images (P < 0.001); however, there was no significant difference in the mean noise of the liver parenchyma between the 69-keV and 70-keV VMS images (P = 0.279). For 95% of the hepatic metastases (288/303 metastases), the highest metastasis-to-liver CNR was obtained in the 66- to 71- keV VMS images. The mean metastasis-to-liver CNR for the 303 metastases was numerically highest at 68 keV; however, there was no significant difference in the mean metastasis-to-liver CNR between the 68-keV and 69-keV images (P = 0.737) or between the 68-keV and 70-keV images (P = 0.103). VMS imaging at approximately 70 keV (69-70 keV) yielded the lowest image noise of the liver parenchyma and a high CNR for hypovascular hepatic metastases in the portal-dominant phase.

1 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YYYoshitake Yamada
Yoshitake Yamada
MYMinoru Yamada
Minoru Yamada
SCShotaro Chubachi
Shotaro Chubachi
YYYoichi Yokoyama
Yoichi Yokoyama
SMShiho Matsuoka
Shiho Matsuoka
MJMasahiro Jinzaki
Masahiro Jinzaki
Currently, no clinical studies have compared the inspiratory and expiratory volumes of unilateral lung or of each lobe among supine, standing, and sitting positions. In this prospective study, 100 asymptomatic volunteers underwent both low-radiation-dose conventional (supine position, with arms raised) and upright computed tomography (CT) (standing and sitting positions, with arms down) during inspiration and expiration breath-holds and pulmonary function test (PFT) on the same day. We compared the inspiratory/expiratory lung/lobe volumes on CT in the three positions. The inspiratory and expiratory bilateral upper and lower lobe and lung volumes were significantly higher in the standing/sitting positions than in the supine position (5.3–14.7% increases, all P < 0.001). However, the inspiratory right middle lobe volume remained similar in the three positions (all P > 0.15); the expiratory right middle lobe volume was significantly lower in the standing/sitting positions (16.3/14.1% decrease) than in the supine position (both P < 0.0001). The Pearson’s correlation coefficients (r) used to compare the total lung volumes on inspiratory CT in the supine/standing/sitting positions and the total lung capacity on PFT were 0.83/0.93/0.95, respectively. The r values comparing the total lung volumes on expiratory CT in the supine/standing/sitting positions and the functional residual capacity on PFT were 0.83/0.85/0.82, respectively. The r values comparing the total lung volume changes from expiration to inspiration on CT in the supine/standing/sitting positions and the inspiratory capacity on PFT were 0.53/0.62/0.65, respectively. The study results could impact preoperative CT volumetry of the lung in lung cancer patients (before lobectomy) for the prediction of postoperative residual pulmonary function, and could be used as the basis for elucidating undetermined pathological mechanisms. Furthermore, in addition to morphological evaluation of the chest, inspiratory and expiratory upright CT may be used as an alternative tool to predict lung volumes such as total lung capacity, functional residual capacity, and inspiratory capacity in situation in which PFT cannot be performed such as during an infectious disease pandemic, with relatively more accurate predictability compared with conventional supine CT.