Yoshikiyo Moriguchi

Dr. Yoshikiyo Moriguchi

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2018 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
YMYoshikiyo Moriguchi
Yoshikiyo Moriguchi
YTYu Tokizane
Yu Tokizane
YTYuma Takida
Yuma Takida
KNKouji Nawata
Kouji Nawata
TETaizo Eno
Taizo Eno
HMHiroaki Minamide
Hiroaki Minamide
A widely tunable terahertz (THz)-wave generation that has a high repetition rate and a narrow line width is demonstrated in this paper by injection-seeded THz-wave parametric generation (is-TPG) in a MgO:LiNbO3 crystal. By pumping the crystal using a passively Q-switched neodymium-doped yttrium vanadate microchip laser with a time duration of 140 ps and an average power of up to 5 W, a THz-wave output with an average output power of 30 μW, a peak power of 4 W, a pulse duration of 73 ps, and a pulse-repetition frequency of 100 kHz is obtained. To prevent laser damage and photorefractive damage to the crystal, the constraints on the pumping condition of the MgO:LiNbO3 crystal are experimentally studied by changing the pumping parameters. As a result, we achieved the stable generation of the THz-wave signal in the 100 kHz regime. Moreover, we performed THz-wave imaging by using the developed is-TPG source. The obtained THz image indicated that the developed system has a good stability over long periods of time.

14 July 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
TMToshihiro Mino
Toshihiro Mino
YMYoshikiyo Moriguchi
Yoshikiyo Moriguchi
MTMasato Tamura
Masato Tamura
AMAkiko Matsumoto
Akiko Matsumoto
AKAtsushi Kubota
Atsushi Kubota
ZWZhenguo Wang
Zhenguo Wang
A novel scanning protocol, ammonite scan, is proposed for widefield optical coherence tomography angiography (OCTA) and relative retinal blood flow velocity imaging in the human retina using variable interscan time analysis (VISTA). A repeated circle scan using a 400 kHz swept-source was employed to achieve an interscan time of 1.28 ms. The center of the repeated circular scan continuously moved spirally towards the peripheral region, ensuring an extended and adjustable scan range while preserving the short interscan time. Image artifacts due to eye movement were eliminated via extra motion-correction processing using data redundancy. The relative blood flow velocity in superficial and deep plexus layers was calculated from the VISTA image, and their ratio was used to explore the microvascular flow parameter in the healthy human eye.& COPY; 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

1 September 2021 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HMHiroaki Minamide
Hiroaki Minamide
KNKouji Nawata
Kouji Nawata
YMYoshikiyo Moriguchi
Yoshikiyo Moriguchi
YTYuma Takida
Yuma Takida
TNTakashi Notake
Takashi Notake
An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) with a footprint the size of an A3 paper is presented. We improved the measurement performance of the is-TPG source for nondestructive inspection applications. A high pulse repetition rate up to 70 kHz and a low pulse timing jitter of a few tens of picoseconds, which is approximately one ten-thousandth of the conventional is-TPG, were achieved. THz waves exhibited excellent performance with a maximum average output power of 20 µW, a monochromatic spectrum linewidth of ∼20 GHz, and a frequency tuning range of 1.7–3.0 THz. This was achieved by designing the entire system configuration from the pump laser source to THz-wave generation. A new double-pass all-solid-state optical amplifier was developed with a high gain and low noise using an externally pulse-modulated laser diode (LD) as the master oscillator source. An achromatic optical injection system was developed for the is-TPG with a 40% reduction in the conventional path length. They were housed in a single enclosure in two layers. LDs and optical fiber amplifiers could be rack-mounted, and the outputs were delivered to the housing via optical fibers. The developed THz-wave source performed nondestructive imaging of a human hair sample fixed with Scotch tape on a test pattern in an envelope by irradiating 2.1 THz waves. A clearly recognizable THz-wave image of an enclosed hair with a spatial resolution close to the THz wavelength was obtained.

17 December 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
YMYoshikiyo Moriguchi
Yoshikiyo Moriguchi
YTYu Tokizane
Yu Tokizane
YTYuma Takida
Yuma Takida
KNKouji Nawata
Kouji Nawata
SNShigenori Nagano
Shigenori Nagano
HMHiroaki Minamide
Hiroaki Minamide
An injection-seeded terahertz (THz)-wave parametric generator (is-TPG) enables access to low-frequency fingerprints of molecules in the THz frequency region. However, its conventional scan repetition rate (SRR) is limited below 1 Hz. Thus, in this Letter, we propose an electrically controlled tuning system for the is-TPG, which provides high-speed scanning and random hopping agility. We achieved rapid THz frequency scanning on a pulse-by-pulse basis by employing a gain-switched laser diode and a micro-electromechanical system tunable vertical-cavity surface-emitting laser as the pump and seed lasers. A THz spectrum was acquired with a 10 times higher SRR of 10 Hz for the 1.6–3 THz range with a sampling resolution of 4.6 GHz.

18 October 2021 in Applied Optics
Verified
Journal Article
Closed access
MTMasato Tamura
Masato Tamura
YMYoshikiyo Moriguchi
Yoshikiyo Moriguchi
SYShu-Yun Yeh
Shu-Yun Yeh
AMAkiko Matsumoto
Akiko Matsumoto
MSMasahiro Shibutani
Masahiro Shibutani
MAMasahiro Akiba
Masahiro Akiba
High lateral resolution ( ∼ 5 µ m ) optical coherence tomography (OCT) that employs a variable cross-cylinder (VCC) to compensate for astigmatism is presented for visualizing minute structures of the human retina. The VCC and its sensorless optimization process enable ocular astigmatism correction of up to − 5.0 diopter within a few seconds. VCC correction has been proven to increase the signal-to-noise ratio and lateral resolution using a model eye. This process is also validated using the human eye by visualizing the capillary network and human cone mosaic. The proposed method is applicable to existing OCT, making high lateral resolution OCT practical in clinical settings.

11 June 2010 in Physical Review B
Verified
Journal Article
Closed access
YSYuika Saito
Yuika Saito
MHMitsuhiro Honda
Mitsuhiro Honda
YMYoshikiyo Moriguchi
Yoshikiyo Moriguchi
PVPrabhat Verma
Prabhat Verma
The photopolymerization of carbon-60 (C60) molecules encapsulated inside single-walled carbon nanotube (en-C60) is investigated through far-field and near-field Raman spectroscopies. In general, a moderately intense laser irradiation invokes complete photopolymerization of nonencapsulated bulk C60 molecules (bulk-C60). However, in contrast, we observed in our experiments that the en-C60 molecules never get completely polymerized, even under long and strong irradiation. In both far-field and near-field Raman measurements, we observed evidences of simultaneous occurrence of polymerization and depolymerization of en-C60 during the process of irradiation. The temporal fluctuation of Raman intensity associated with C60-monomer peak confirmed that en-C60 molecules jump back and forth between the polymerized and depolymerized states. The results have been discussed through the unique movement of C60 molecules inside nanotube, and through the interaction between C60 molecules with the inner wall of the nanotube in en-C60 sample, which generates frictional heat, responsible for the scission of polymeric bonds between neighboring C60 molecules. The frictional scission competes with the photopolymerization process, resulting in a temporally dynamic situation where the sample can never get completely polymerized even under strong irradiation. DOI: http://dx.doi.org/10.1103/PhysRevB.81.245416 © 2010 The American Physical Society