Long WU

Long WU

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2024 in Journal of Neural Engineering
Verified
Journal Article
Open access
LWLong WU
Long WU
SWScott Wellington
Scott Wellington
ZFZhichun Fu
Zhichun Fu
DZDingguo Zhang
Dingguo Zhang
Objective. Brain–computer interfaces (BCIs) are technologies that bypass damaged or disrupted neural pathways and directly decode brain signals to perform intended actions. BCIs for speech have the potential to restore communication by decoding the intended speech directly. Many studies have demonstrated promising results using invasive micro-electrode arrays and electrocorticography. However, the use of stereo-electroencephalography (sEEG) for speech decoding has not been fully recognized. Approach. In this research, recently released sEEG data were used to decode Dutch words spoken by epileptic participants. We decoded speech waveforms from sEEG data using advanced deep-learning methods. Three methods were implemented: a linear regression method, an recurrent neural network (RNN)-based sequence-to-sequence model (RNN), and a transformer model. Main results. Our RNN and transformer models outperformed the linear regression significantly, while no significant difference was found between the two deep-learning methods. Further investigation on individual electrodes showed that the same decoding result can be obtained using only a few of the electrodes. Significance. This study demonstrated that decoding speech from sEEG signals is possible, and the location of the electrodes is critical to the decoding performance.

1 July 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
LWLong WU
Long WU
BMBenjamin Metcalfe
Benjamin Metcalfe
Shenghong HeShenghong He
Shenghong He
HTHuiling Tan
Huiling Tan
ZDZhang Dingguo
Zhang Dingguo
Brain-computer interfaces (BCIs) provide a communication interface between the brain and external devices and have the potential to restore communication and control in patients with neurological injury or disease. For the invasive BCIs, most studies recruited participants from hospitals requiring invasive device implantation. Three widely used clinical invasive devices that have the potential for BCIs applications include surface electrodes used in electrocorticography (ECoG) and depth electrodes used in Stereo-electroencephalography (SEEG) and deep brain stimulation (DBS). This review focused on BCIs research using surface (ECoG) and depth electrodes (including SEEG, and DBS electrodes) for movement decoding on human subjects. Unlike previous reviews, the findings presented here are from the perspective of the decoding target or task. In detail, five tasks will be considered, consisting of the kinematic decoding, kinetic decoding, identification of body parts, dexterous hand decoding, and motion intention decoding. The typical studies are surveyed and analyzed. The reviewed literature demonstrated a distributed motor-related network that spanned multiple brain regions. Comparison between surface and depth studies demonstrated that richer information can be obtained using surface electrodes. With regard to the decoding algorithms, deep learning exhibited superior performance using raw signals than traditional machine learning algorithms. Despite the promising achievement made by the open-loop BCIs, closed-loop BCIs with sensory feedback are still in their early stage, and the chronic implantation of both ECoG surface and depth electrodes has not been thoroughly evaluated.

6 February 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
LWLong WU
Long WU
SJShize Jiang
Shize Jiang
GLGuangye Li
Guangye Li
SLShengjie Liu
Shengjie Liu
BMBenjamin Metcalfe
Benjamin Metcalfe
ZDZhang Dingguo
Zhang Dingguo
Objective: Deep learning based on convolutional neural networks (CNN) has achieved success in brain-computer interfaces (BCIs) using scalp electroencephalography (EEG). However, the interpretation of the so-called ‘black box’ method and its application in stereo-electroencephalography (SEEG)-based BCIs remain largely unknown. Therefore, in this paper, an evaluation is performed on the decoding performance of deep learning methods on SEEG signals. Methods: Thirty epilepsy patients were recruited, and a paradigm including five hand and forearm motion types was designed. Six methods, including filter bank common spatial pattern (FBCSP) and five deep learning methods (EEGNet, shallow and deep CNN, ResNet, and a deep CNN variant named STSCNN), were used to classify the SEEG data. Various experiments were conducted to investigate the effect of windowing, model structure, and the decoding process of ResNet and STSCNN. Results: The average classification accuracy for EEGNet, FBCSP, shallow CNN, deep CNN, STSCNN, and ResNet were 35 $\pm$ 6.1%, 38 $\pm$ 4.9%, 60 $\pm$ 3.9%, 60 $\pm$ 3.3%, 61 $\pm$ 3.2%, and 63 $\pm$ 3.1% respectively. Further analysis of the proposed method demonstrated clear separability between different classes in the spectral domain. Conclusion: ResNet and STSCNN achieved the first- and second-highest decoding accuracy, respectively. The STSCNN demonstrated that an extra spatial convolution layer was beneficial, and the decoding process can be partially interpreted from spatial and spectral perspectives. Significance: This study is the first to investigate the performance of deep learning on SEEG signals. In addition, this paper demonstrated that the so-called ‘black-box’ method can be partially interpreted.

13 February 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
LWLong WU
Long WU
GLGuangye Li
Guangye Li
XGXin Gao
Xin Gao
BMBenjamin Metcalfe
Benjamin Metcalfe
ZDZhang Dingguo
Zhang Dingguo
Brain-computer interfaces (BCIs) can enable direct communication with assistive devices by recording and decoding signals from the brain. To achieve high performance, many electrodes will be used, such as the recently developed invasive BCIs with channel numbers up to hundreds or even thousands. For those high-throughput BCIs, channel selection is important to reduce signal redundancy and invasiveness while maintaining decoding performance. However, such endeavour is rarely reported for invasive BCIs, especially those using deep learning methods. Two deep learning-based methods, referred to as Gumbel and STG, were proposed in this paper. They were evaluated using the Stereo-electroencephalography (SEEG) signals, and compared with three other methods, including manual selection, mutual information-based method (MI), and all channels (all channels without selection). The task is to classify the SEEG signals into five movements using channels selected by each method. When 10 channels were selected, the mean classification accuracies using Gumbel, STG (referred to as STG-10), manual selection, and MI selection were 65%, 60%, 60%, and 47%, respectively, whilst the accuracy was 59% using all channels (no selection). In addition, an investigation of the selected channels showed that Gumbel and STG have successfully identified the pre-central and post-central areas, which are closely related to motor control. Both Gumbel and STG successfully selected the informative channels in SEEG recordings while maintaining decoding accuracy. This study enables future high-throughput BCIs using deep learning methods, to identify useful channels and reduce computing and wireless transmission pressure.

1 February 2024 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
LWLong WU
Long WU
DZDingguo Zhang
Dingguo Zhang
GLGuangye Li
Guangye Li
XGXin Gao
Xin Gao
BMBenjamin Metcalfe
Benjamin Metcalfe
LCLiang Chen
Liang Chen
Objective. Deep learning is increasingly used for brain–computer interfaces (BCIs). However, the quantity of available data is sparse, especially for invasive BCIs. Data augmentation (DA) methods, such as generative models, can help to address this sparseness. However, all the existing studies on brain signals were based on convolutional neural networks and ignored the temporal dependence. This paper attempted to enhance generative models by capturing the temporal relationship from a time-series perspective. Approach. A conditional generative network (conditional transformer-based generative adversarial network (cTGAN)) based on the transformer model was proposed. The proposed method was tested using a stereo-electroencephalography (SEEG) dataset which was recorded from eight epileptic patients performing five different movements. Three other commonly used DA methods were also implemented: noise injection (NI), variational autoencoder (VAE), and conditional Wasserstein generative adversarial network with gradient penalty (cWGANGP). Using the proposed method, the artificial SEEG data was generated, and several metrics were used to compare the data quality, including visual inspection, cosine similarity (CS), Jensen–Shannon distance (JSD), and the effect on the performance of a deep learning-based classifier. Main results. Both the proposed cTGAN and the cWGANGP methods were able to generate realistic data, while NI and VAE outputted inferior samples when visualized as raw sequences and in a lower dimensional space. The cTGAN generated the best samples in terms of CS and JSD and outperformed cWGANGP significantly in enhancing the performance of a deep learning-based classifier (each of them yielding a significant improvement of 6% and 3.4%, respectively). Significance. This is the first time that DA methods have been applied to invasive BCIs based on SEEG. In addition, this study demonstrated the advantages of the model that preserves the temporal dependence from a time-series perspective.

1 April 2022 in Journal of Neural Engineering
Verified
Journal Article
Open access
LWLong WU
Long WU
GLGuangye Li
Guangye Li
SJShize Jiang
Shize Jiang
SWScott Wellington
Scott Wellington
SLShengjie Liu
Shengjie Liu
DZDingguo Zhang
Dingguo Zhang
Objective. Brain–computer interfaces (BCIs) have the potential to bypass damaged neural pathways and restore functionality lost due to injury or disease. Approaches to decoding kinematic information are well documented; however, the decoding of kinetic information has received less attention. Additionally, the possibility of using stereo-electroencephalography (SEEG) for kinetic decoding during hand grasping tasks is still largely unknown. Thus, the objective of this paper is to demonstrate kinetic parameter decoding using SEEG in patients performing a grasping task with two different force levels under two different ascending rates. Approach. Temporal-spectral representations were studied to investigate frequency modulation under different force tasks. Then, force amplitude was decoded from SEEG recordings using multiple decoders, including a linear model, a partial least squares model, an unscented Kalman filter, and three deep learning models (shallow convolutional neural network, deep convolutional neural network and the proposed CNN+RNN neural network). Main results. The current study showed that: (a) for some channel, both low-frequency modulation (event-related desynchronization (ERD)) and high-frequency modulation (event-related synchronization) were sustained during prolonged force holding periods; (b) continuously changing grasp force can be decoded from the SEEG signals; (c) the novel CNN+RNN deep learning model achieved the best decoding performance, with the predicted force magnitude closely aligned to the ground truth under different force amplitudes and changing rates. Significance. This work verified the possibility of decoding continuously changing grasp force using SEEG recordings. The result presented in this study demonstrated the potential of SEEG recordings for future BCI application.