Purpose. Meibomian gland dysfunction (MGD) can lead to abnormalities in the composition and function of tear film, resulting in dry eye. Eyelid hygiene is a key to management of MGD. We tested a novel eyelid shampoo (Eye Shampoo Long, ESL) for its ability to maintain lid hygiene. This shampoo is nonirritating and can potentially lengthen eyelashes. This study was aimed to evaluate the efficacy of ESL in the treatment of MGD and its effects on eyelash length. Methods. Ten patients with MGD and 10 healthy subjects without MGD applied ESL twice daily for 8 weeks. Patients were examined for lid margin and dry eye before and after the trial. Subjective symptoms were evaluated. Eyelash length was measured at baseline and at the end of the trial. Results. In the MGD group, significant improvements were observed in subjective symptoms obstruction of the meibomian orifice, secretion of meibum, eyelashes contamination, eyelid margin foam, and SPK. Eyelash length became significantly longer. Conclusions. Maintaining eyelid hygiene using ESL improved the eyelid margins and symptoms of dry eye in MGD patients and increased eyelash length. These findings are promising and warrant confirmation in a larger randomized controlled study.
1 November 2015 in Plastic and Reconstructive Surgery - Global Open
Background: Blue light has more energy than longer wavelength light and can penetrate the eye to reach the retina. When surgeons use magnifying loupes under intensive surgical shadowless lamps for better view of the surgical field, the total luminance is about 200 times brighter than that of typical office lighting. In this study, the effects of 2 types of shadowless lamps were compared. Moreover, the effect of various eyeglasses, which support magnifying loupes, on both the light energy and color rendering was considered. Methods: The light intensity and color rendering were measured on 3 variables: light transmittance, light intensity, and color rendering. Results: Under shadowless lamps, the light energy increased with low-magnification loupes and decreased with high-magnification loupes. Filtering eyeglasses reduced the energy, especially in conditions where the low-magnification loupe was used. The best color-rendering index values were obtained with computer eyeglasses under conventional light-emitting diode shadowless lamps and with no glass and with lightly yellow-tinted lenses under less-blue light-emitting diode. Conclusions: Microsurgeons are exposed to strong lighting throughout their career, and proper color rendering must be considered for easier recognition. Light toxicity and loss of color rendering can be reduced with an appropriate combination of shadowless lamps and colored eyeglasses.
Introduction: We present seven cases of infectious keratitis after corneal crosslinking (CXL) to attenuate keratoconus progression. Methods: Of 524 consecutive patients who underwent CXL, 7 cases (4 males and 3 females; 21.5 ± 7.1 years) developed postoperative infectious keratitis were retrospectively reviewed. CXL was performed using the Dresden protocol or an accelerated protocol involving epithelial removal. Results: All cases appeared normal on the day after surgery, but subsequently developed eye pain, blurred vision, corneal infiltration, inflammation of the anterior chamber, and ciliary injection on day 2 or 3. Methicillin-resistant Staphylococcus aureus was cultured from two eyes, methicillin-sensitive Staphylococcus aureus from two eyes, and Streptococcus pneumoniae from one eye. All detected bacteria were resistant to levofloxacin (LVFX). Five of the seven cases, especially four of the five severe cases with hypopyon, had a history of atopic dermatitis. All cases were observed after 2015. Conclusions: Infectious keratitis after CXL caused by microbes resistant to LVFX is increasing. In addition to careful postoperative observation of the cornea, preoperative evaluation of bacteria within the conjunctival sac evident on nasal swab cultures may be useful to identify potentially problematic microbes and inform the selection of appropriate antibiotics.
1 December 2014 in Taiwan Journal of Ophthalmology
PurposeTo evaluate the results of laser in situ laser keratomileusis (LASIK) for myopia/myopic astigmatism over a 10-year period.MethodsWe examined LASIK patients who received regular postoperative assessments over 10 years. We evaluated uncorrected visual acuity (UCVA), manifest refraction, best-corrected visual acuity, intraocular pressure, retreatment rate, safety, efficacy, and complications.ResultsWe studied 5423 eyes between December 1997 and February 2002. The study criteria were met by 346 eyes. A UCVA of 20/40 was achieved in 86.1% of the patients, with 52.0% achieving 20/20 at 10 years. Refraction within 1.00 σ of target was achieved in 76.3% of the patients, and 95.7% were within 2.00 σ at 10 years. Retreatment was required in 124 eyes (35.8%). The preoperative logMAR UCVA of 1.24 improved to −0.08 at 1 month, and slightly decreased to 0.06 at 10 years. The safety and efficacy indices were 1.0 and 0.89 at 1 month, and 0.99 and 0.71 at 10 years.ConclusionWe analyzed 6.3% of patients who regularly returned for postoperative examinations. Despite the relatively low 10-year-visit rate and the inclusion of single- and multiple-treatment cases, our results may represent the real-world picture of LASIK; furthermore, our study shows that LASIK is an effective and safe procedure
1 July 1997 in Biochemical and Biophysical Research Communications
Purpose: To report the technique of combining the two different polarization filters to detect the flap edge of the corneoscleral tissue before trephining the Descemet's stripping automated endothelial keratoplasty (DSAEK) tissue. Methods: A human DSAEK donor tissue was prepared with mechanical microkeratome and the tissue on the cutting block was brought under the microscope. The liner, circular, or the combination of these two polarization filters was placed be-tween the tissue and the microscope. The tissue images were taken with digital camera under either of 3 settings. Results: The combination of circular and linear polarization filters enabled us to recognize the edge of the flap more easily than others. Conclusion: This simple system with polarization filters was effective in clear visualization of the flap edge during DSAEK tissue preparation. These features may significantly enhance safety of various surgical procedures, in addition to DSAEK tissue preparation.