Geethanjali P

Geethanjali P


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
GPGeethanjali P
Geethanjali P
Myoelectric signals (MES) have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy.

30 June 2016 in IEEE Access
Verified
Journal Article
Open access
SAsharmila Ashok
sharmila Ashok
GPGeethanjali P
Geethanjali P
Electroencephalogram (EEG) comprises valuable details related to the different physiological state of the brain. In this paper, a framework is offered for detecting the epileptic seizures from EEG data recorded from normal subjects and epileptic patients. This framework is based on a discrete wavelet transform (DWT) analysis of EEG signals using linear and nonlinear classifiers. The performance of the 14 different combinations of two-class epilepsy detection is studied using naïve Bayes (NB) and k-nearest neighbor (k-NN) classifiers for the derived statistical features from DWT. It has been found that the NB classifier performs better and shows an accuracy of 100% for the individual and combined statistical features derived from the DWT values of normal eyes open and epileptic EEG data provided by the University of Bonn, Germany. It has been found that the computation time of NB classifier is lesser than k-NN to provide better accuracy. So, the detection of an epileptic seizure based on DWT statistical features using NB classifiers is more suitable in real time for a reliable, automatic epileptic seizure detection system to enhance the patient's care and the quality of life.

26 July 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BNB. R. Nayana
B. R. Nayana
GPGeethanjali P
Geethanjali P
The frequency of rolling element failures in induction motor is high and may lead to losses due to sudden downtime of machine. Researchers are fervent to identify an effective fault diagnosing scheme with less computational burden using optimum number of good discriminating features. We attempted time domain features, namely, waveform length (WL), slope sign changes (SSC), simple sign integral and Wilson amplitude for the first time in addition to established mean absolute value and zero crossing (ZC) for identification of mechanical faults of induction motor. Ten data sets are derived from publicly available vibration database of Case Western Reserve University to identify the capability of features in identification of faults under various conditions. The results are compared with six conventional features for tenfold cross validation using linear discriminant analysis, naive Bayes, and support vector machine classifiers. The results have shown that WL, WAMP, ZC, and SSC outperform other features. Furthermore, area under receiver operator characteristics curve analyses showed an average of 0.9987 with the proposed statistical features and 0.97618 with six conventional features. We also attempted to study the effect of data length and percentage of overlap in classification and found accuracy improves with increase in length but not significant beyond the window length of 3000 with 50% overlap. The proposed statistical features are validated using the brute force method and Laplaician method of feature selection and shown an average accuracy rate of 0.9936 and 0.9894, respectively.

1 March 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
PKP. Ashwini Kumari
P. Ashwini Kumari
GPGeethanjali P
Geethanjali P

27 April 2020 in Transactions on Emerging Telecommunications Technologies
Verified
Journal Article
Closed access
PDF file
SJSebastian Terence J.
Sebastian Terence J.
GPGeethanjali P
Geethanjali P

14 October 2014 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
GPGeethanjali P
Geethanjali P
KRK. K. Ray
K. K. Ray
The focus of this paper is the development of a low-cost research platform for a surface electromyogram (EMG)-based prosthetic hand control to evaluate various pattern recognition techniques and to study the real-time implementation. This comprehensible research platform may enlighten the biomedical research in developing countries for analyzing and evaluating the surface EMG signals. Major challenges in this work were as follows: the design and development of an EMG signal conditioning module, a pattern recognition module, and a prosthetic hand at low cost. Besides, EMG pattern recognition techniques were evaluated for identifying six hand motions in offline with signals acquired from ten healthy subjects and two transradial amputees. Features calculated from EMG signals were grouped into six ensembles to apprehend the vitality of the ensemble in classifiers namely simple logistic regression (SLR), J48 algorithm for decision tree, logistic model tree, neural network, linear discriminant analysis, and support vector machine. The classification performance was also evaluated with the prolonged EMG data recorded on a day at every 1 h interval to study the robustness of the classifier. The results show the average classification accuracy, processing time and memory requirement of the SLR was found to be better and robust with time-domain features consisting of statistical as well as autoregression coefficients. The statistical analysis of variance test also showed that computation time and memory space required for SLR were significantly less compared to the other classifiers. The performance of the classifier was tested in online with transradial amputee for actuation of prosthetic hand for two intended motions with a TMS320F28335 controller. This proposed research platform for evaluation of EMG pattern recognition and real-time implementation has been achieved at a cost of 25 000 Indian rupee (INR).