Jakob Scheibler

Mr. Jakob Scheibler


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
ASAntje Schauer
Antje Schauer
CRChristian Redlich
Christian Redlich
JSJakob Scheibler
Jakob Scheibler
GPGeorg Poehle
Georg Poehle
PBPeggy Barthel
Peggy Barthel
PQPeter Quadbeck
Peter Quadbeck
The biocompatibility and degradation behavior of pure molybdenum (Mo) as a bioresorbable metallic material (BMM) for implant applications were investigated. In vitro degradation of a commercially available Mo wire (ø250 µm) was examined after immersion in modified Kokubo’s SBF for 28 days at 37 °C and pH 7.4. For assessment of in vivo degradation, the Mo wire was implanted into the abdominal aorta of female Wistar rats for 3, 6 and 12 months. Microstructure and corrosion behavior were analyzed by means of SEM/EDX analysis. After explantation, Mo levels in serum, urine, aortic vessel wall and organs were investigated via ICP-OES analysis. Furthermore, histological analyses of the liver, kidneys, spleen, brain and lungs were performed, as well as blood count and differentiation by FACS analysis. Levels of the C-reactive protein were measured in blood plasma of all the animals. In vitro and in vivo degradation behavior was very similar, with formation of uniform, non-passivating and dissolving product layers without occurrence of a localized corrosion attack. The in vitro degradation rate was 101.6 µg/(cm2·d) which corresponds to 33.6 µm/y after 28 days. The in vivo degradation rates of 12, 33 and 36 µg/(cm2·d) were observed after 3, 6 and 12 months for the samples properly implanted in the aortic vessel wall. This corresponds with a degradation rate of 13.5 µm/y for the 12-month cohort. However, the magnitude of degradation strongly depended on the implant site, with the wires incorporated into the vessel wall showing the most severe degradation. Degradation of the implanted Mo wire neither induced an increase in serum or urine Mo levels nor were elevated Mo levels found in the liver and kidneys compared with the respective controls. Only in the direct vicinity of the implant in the aortic vessel wall, a significant amount of Mo was found, which, however, was far below the amounts to be expected from degrading wires. No abnormalities were detected for all timepoints in histological and blood analyses compared to the control group. The C-reactive protein levels were similar between all the groups, indicating no inflammation processes. These findings suggest that dissolved Mo from a degrading implant is physiologically transported and excreted. Furthermore, radiographic and µCT analyses revealed excellent radiopacity of Mo in tissues. These findings and the unique combination with its extraordinary mechanical properties make Mo an interesting alternative for established BMMs.

5 May 2021 in Metals
Verified
Journal Article
Open access
PDF file
CRChristian Redlich
Christian Redlich
ASAntje Schauer
Antje Schauer
JSJakob Scheibler
Jakob Scheibler
GPGeorg Poehle
Georg Poehle
PBPeggy Barthel
Peggy Barthel
PQPeter Quadbeck
Peter Quadbeck
The degradation behavior and biocompatibility of pure molybdenum (Mo) were investigated. Dissolution of powder metallurgically manufactured and commercially available Mo was investigated by ion concentration measurement after immersion in modified Kokubo’s SBF (c-SBF-Ca) for 28 days at 37 °C and pH 7.4. Degradation layers and corrosion attack were examined with optical microscopy and REM/EDX analysis. Furthermore, potentiodynamic polarization measurements were conducted. Mo gradually dissolves in modified SBF releasing molybdate anions (MoO42−). The dissolution rate after 28 days is 10 µm/y for both materials and dissolution accelerates over time. A non-passivating, uniform and slowly soluble degradation product layer is observed. Additionally, apoptosis and necrosis assays with Mo ion extracts and colonization tests with human endothelial (HCAEC) and smooth muscle cell lines (HCASMC) on Mo substrates were performed. No adverse effects on cell viability were observed for concentrations expected from the dissolution of implants with typical geometries and substrates were densely colonized by both cell lines. Furthermore, Mo does not trigger thrombogenic or inflammatory responses. In combination with its favorable mechanical properties and the renal excretion of bio-available molybdate ions, Mo may be an alternative to established bioresorbable metals.

8 November 2024 in Metals
Verified
Journal Article
Open access
PDF file
JSJakob Scheibler
Jakob Scheibler
AKAlina Sabine Kosmehl
Alina Sabine Kosmehl
TSThomas Studnitzky
Thomas Studnitzky
CZChongliang Zhong
Chongliang Zhong
TWThomas Weißgärber
Thomas Weißgärber
Copper’s high thermal and electrical conductivity enables its application in heat exchangers and high-frequency components. For those applications, additive manufacturing has advantages with respect to functional integration, miniaturization, and reduced waste. However, the processing of copper is a challenge for established laser-based processes since copper’s high reflectivity impedes energy input. Sinter-based additive manufacturing processes do not exhibit this limitation since the energy for the fusion of material is applied by thermal energy during sintering. This makes them an ideal candidate for copper manufacturing. In the following work, Lithography-based Metal Manufacturing (LMM) of copper is demonstrated. Curing behavior is investigated by single-layer exposure (SLE) tests measuring curing thickness for different loading factors, particle sizes, and exposure times. Bending strength is investigated as a function of exposure time, loading factor, and orientation in the building space. A higher exposure time and lower loading factors increase bending strength. Furthermore, samples with different loading factors are produced to measure the impact of the loading factor on sintered density. For these parameters, no clear trend is demonstrated.