Wei Li

Mr. Wei Li


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
YYYidan Yuan
Yidan Yuan
XHXiaodong Huo
Xiaodong Huo
WLWei Li
Wei Li
QGQiang Guo
Qiang Guo
LZLi Zhang
Li Zhang
JPJie Pei
Jie Pei
As the cornerstone of severe accident management strategy, either in-vessel or ex-vessel retention of core melt (IVR or EVR) plays a pivotal role in the stabilization and termination of a severe accident and ultimately secures the safety goal of “Practical elimination of large radioactive release” for light water reactors. In contrast to the IVR measures that are more or less identical in reactor designs, the EVR measures are quite different from design to design. This study intended to give a critical review on the EVR measures adopted in the reactor designs of VVER-1000, EPR, ESBWR, EU-APR1400 and APWR. The review study began with a general description of the existing EVR measures, including their principles, operational procedures and research efforts. We then focused our discussions on the pros and cons of each EVR measure through the comparisons with the IVR and with the others in terms of simplicity, reliability and economy. We finally tried to identify the remaining issues and uncertainties in the qualification of the EVR measures, based on which potential design improvements and future research needs were recommended.

27 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
HWHongliang Wang
Hongliang Wang
MYMingrui Yu
Mingrui Yu
YGYong Guo
Yong Guo
YFYu Feng
Yu Feng
WLWei Li
Wei Li
Yidan YuanYidan Yuan
Yidan Yuan
The wind loading test serves as a critical validation experiment for the Passive Air-Cooling System (PAS) ACP100. However, it remains unclear how the highly scaled-down experimental setup can accurately account for the influence of the steel shell wall heating conditions on the airflow dynamics within the PAS flow channel. This study employs both numerical simulations and experimental investigations to compare and analyze variations in pressure and temperature within the PAS flow channel under the different heating temperatures of a steel shell wall, considering scenarios with and without environmental wind field effects. The objective is to assess the influence and necessity of heating conditions. In this study, ANSYS Fluent 18.2 was utilized to conduct numerical simulations of the 1:126 scale model of ACP100. Subsequently, the 1:126-scale ACP100 test model was placed on a wind tunnel platform to investigate various experimental conditions. Key parameters, including pressure, temperature, and wind velocity, were meticulously measured at critical locations to obtain detailed insights into the model’s performance under different scenarios. The results indicate that the numerical calculations are consistent with the findings from experimental research. When the environmental wind velocity is 0 m/s, the pressure deviation (∆Pmax) at each measurement position within the PAS flow channel, under varying heating wall temperatures of 55.8 °C, 93.5 °C and 126.8 °C, remains below 1.8 Pa. Furthermore, the inlet and outlet pressure difference (∆Pio) is less than 3.9 Pa, which is insufficient to establish natural circulation. Additionally, it was observed that the air temperature increases continuously from the PAS inlet to the top outlet; notably, the air temperature at the top outlet approaches that of the heating wall temperature, nearly reaching equilibrium. When examining the coupling effect of the environmental wind field, it is observed that the pressure difference (∆Pio) between the inlet and top outlet of the PAS flow channel increases significantly. However, the pressure deviation at each measurement position within the PAS flow channel remains within acceptable limits, satisfying ∆Pmax < 3 Pa. Furthermore, the temperature deviation (∆Tmax ≤ 2.8 °C) at each measuring position in the PAS channel indicates that the influence of the environmental wind field on both pressure and temperature distribution is relatively minor and can be safely neglected. In summary, it can be concluded that when utilizing the ACP100 scaled-down model for research on a PAS wind loading performance test, there is no necessity to establish heating conditions as their effects can be disregarded.

17 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
HWHongliang Wang
Hongliang Wang
YFYu Feng
Yu Feng
MYMingrui Yu
Mingrui Yu
YGYong Guo
Yong Guo
WLWei Li
Wei Li
Yidan YuanYidan Yuan
Yidan Yuan
In addition to convective heat transfer, radiation heat transfer constitutes a significant component of the thermal performance of Passive Containment Air-Cooling System (PAS). The installation of radiation plates within the PAS flow channel enhances the convective heat transfer area between the wall and the air, an effect that should not be overlooked. ANSYS Fluent was employed to investigate how the placement and quantity of radiation plates influence the heat transfer efficiency of PAS. The computational results indicate that radiation plates can substantially enhance the thermal performance of PAS. Specifically, when a radiation plate is positioned 0.9 m from the inner wall of the concrete shell, an improvement in PAS heat transfer power by as much as 34.4% can be achieved. However, it was observed that increasing the number of radiation plates has a minimal impact on overall performance; thus, utilizing multiple plates does not further augment the PAS heat transfer capability. Nonetheless, incorporating several radiation plates may contribute to lowering the temperature of the concrete shell. Based on this research, it can be concluded that strategically arranging radiation plates significantly improves the PAS heat transfer capacity. While multiple radiation plates do not provide additional enhancements to heat transfer efficiency under normal conditions, they remain a viable option for mitigating concrete shell temperatures during accident scenarios.

2 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
JXJi Xing
Ji Xing
XHXiaodong Huo
Xiaodong Huo
WLWei Li
Wei Li
YYYidan Yuan
Yidan Yuan
QGQiang Guo
Qiang Guo
WMWeimin Ma
Weimin Ma
As the cornerstone of severe accident management strategy, either in-vessel or ex-vessel retention of core melt (IVR or EVR) plays a pivotal role in the stabilization and termination of a severe accident, and ultimately secures the safety goal of “Practical elimination of large radioactive release” for light water reactors. In contrast to the IVR measures that are more or less identical in reactor designs, the EVR measures are quite different from design to design. This paper was intended to give a critical review on the EVR measures adopted in the reactor designs of VVER-1000, EPR, ESBWR, EU-APR1400 and APWR. The review study began with a general description of the existing EVR measures, including their principles, operational procedures and research efforts. We then focused our discussions on the pros and cons of each EVR measure, through the comparisons with the IVR and with the others in terms of simplicity, reliability and economy. We finally tried to identify the remaining issues and uncertainties in the qualification of the EVR measures, based on which potential design improvements and future research needs were recommended.