James Flynn

Dr. James Flynn

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2023 in Science
Verified
Journal Article
Closed access
SEStephanie Evan
Stephanie Evan
JBJerome Brioude
Jerome Brioude
KRKaren Rosenlof
Karen Rosenlof
RGRu-Shan Gao
Ru-Shan Gao
RPRobert W. Portmann
Robert W. Portmann
WRWilliam G. Read
William G. Read
The eruption of the Hunga Tonga–Hunga Ha’apai volcano on 15 January 2022 offered a good opportunity to explore the early impacts of tropical volcanic eruptions on stratospheric composition. Balloon-borne observations near Réunion Island revealed the unprecedented amount of water vapor injected by the volcano. The enhanced stratospheric humidity, radiative cooling, and expanded aerosol surface area in the volcanic plume created the ideal conditions for swift ozone depletion of 5% in the tropical stratosphere in just 1 week. The decrease in hydrogen chloride by 0.4 parts per million by volume (ppbv) and the increase in chlorine monoxide by 0.4 ppbv provided compelling evidence for chlorine activation within the volcanic plume. This study enhances our understanding of the effect of this unusual volcanic eruption on stratospheric chemistry and provides insights into possible chemistry changes that may occur in a changing climate.

30 October 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
EAElizabeth Asher
Elizabeth Asher
MTMichael Todt
Michael Todt
KRKaren Rosenlof
Karen Rosenlof
TTTroy Thornberry
Troy Thornberry
RGRu-Shan Gao
Ru-Shan Gao
KXKensy Xiong
Kensy Xiong
The Hunga Tonga–Hunga Ha’apai (HT-HH) volcanic eruptions on January 13 and 15, 2022, produced a plume with the highest signal in stratospheric aerosol optical depth observed since the eruption of Mt. Pinatubo in 1991. Suites of balloon-borne instruments on a series of launches from Réunion Island intercepted the HT-HH plume between 7 and 10 d of the eruptions, yielding observations of the aerosol number and size distribution and sulfur dioxide (SO 2 ) and water vapor (H 2 O) concentrations. The measurements reveal an unexpected abundance of large particles in the plume, constrain the total sulfur injected to approximately 0.2 Tg, provide information on the altitude of the injection, and indicate that the formation of sulfuric acid aerosol was complete within 3 wk. Large H 2 O enhancements contributed as much as ~30% to ambient aerosol surface area and likely accelerated SO 2 oxidation and aerosol formation rates in the plume to approximately three times faster than under normal stratospheric conditions.

28 July 2023 in Atmospheric Environment
Verified
Journal Article
Closed access
MMManisha Mehra
Manisha Mehra
Sujan ShresthaSujan Shrestha
Sujan Shrestha
KAKrishnakumar AP
Krishnakumar AP
MGMeghan Guagenti
Meghan Guagenti
CMClaire E. Moffett
Claire E. Moffett
Rebecca  J. SheesleyRebecca J. Sheesley
Rebecca J. Sheesley

29 July 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SYSubin Yoon
Subin Yoon
AKAlexander Kotsakis
Alexander Kotsakis
SASergio L. Alvarez
Sergio L. Alvarez
MSMark G. Spychala
Mark G. Spychala
EKElizabeth Klovenski
Elizabeth Klovenski
JFJames Flynn
James Flynn
A novel technique has been developed to measure sulfur dioxide (SO2) using a modification of the existing electrochemical concentration cell (ECC) ozonesonde technology. The current sonde-based method to measure SO2 (i.e., the dual-sonde approach) involves launching two ozonesondes together, with one of the sondes having a filter to remove SO2 at the inlet. The SO2 profile is determined by taking the difference between the measurements from the two instruments. The dual-sonde method works well in typical tropospheric conditions when [O3]>[SO2] but saturates when [SO2]>[O3] and has large uncertainties in the upper troposphere and lower stratosphere that would limit its effectiveness in measuring SO2 from an explosive volcanic eruption. Due to these limitations, several modifications were made to create a single-sonde system that would directly measure SO2 (i.e., the SO2 sonde). These modifications included (1) a positively biased ECC current, (2) the addition of an O3 removal filter, and (3) the addition of a sample dryer. The SO2 sonde measures SO2 as a reduction in the cell current. There was a strong correlation (r2>0.94) between the SO2 sonde and a Thermo 43c analyzer during controlled laboratory tests and pre-flight tests. Varying humidity levels affected the SO2 sonde's sensitivity (avg =84.6±31.7 ppbv µA−1, 1σ RSD =37 %) during initial field tests, which was resolved by adding a sample dryer upstream of the O3 removal filter and pump inlet. This modification significantly reduced the variability and increased the sensitivity of the SO2 measurements (avg =47±5.8 ppbv µA−1, 1σ RSD =12 %). Field tests included measurements near Kīlauea volcano (before and during the 2018 eruption of the Lower East Rift Zone), Costa Rica's Turrialba volcano, and anthropogenic plumes from the Athabasca oil sands region of Alberta, Canada. This single-SO2-sonde system is an effective, inexpensive instrument for measuring both ground-based and vertical profiles of SO2 from anthropogenic and natural sources (i.e., volcanic eruptions) over a wide range of concentrations.

10 June 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
Sujan ShresthaSujan Shrestha
Sujan Shrestha
SYsubin yoon
subin yoon
SASergio Luiz Alvarez
Sergio Luiz Alvarez
YWYuxuan Wang
Yuxuan Wang
JFJames Flynn
James Flynn
Rebecca  J. SheesleyRebecca J. Sheesley
Rebecca J. Sheesley
Changing urban emission landscapes and increasing population make it imperative to understand the driving forces for air quality in growing urban areas. Recent field studies in an industrial area in Houston and a semiurban area in San Antonio reveal unique emission signatures for these two growing Texas cities. A comparison of benzene, toluene, xylenes, isoprene, and methyl ethyl ketone (MEK) was conducted for these two Texas locations and previous studies in other megacities. It was found that San Antonio had similar emission ratios as these megacities for benzene, toluene, and xylenes (1.10, 4.57, and 3.60 pptv ppbv−1 of CO, respectively), likely indicating a similar traffic emission source. Isoprene and MEK were of biogenic origin in San Antonio. However, analysis of emission ratios, diurnal trends, and comparison with emission inventories indicated that benzene, toluene, and MEK were likely associated with fugitive and stack emissions in the industrial corridor in Houston. Isoprene in Houston appeared to have mixed fugitive and biogenic sources in Houston, based on diurnal trends and emission ratio. The peak nighttime concentrations for benzene, toluene, xylene, isoprene, and MEK observed during the campaign were 66, 533, 21, 138, and 731 ppbv, respectively, in the Houston site. The emission ratio for xylenes (3.37 pptv ppbv−1 of CO) for the Houston site was similar to Paris, London, and Mexico City, despite emission inventories indicating high fugitive and stack emissions. The conditional probability function (CPF) analysis closely matched the direction of the industrial sources with the highest recorded emission levels as listed in the emission inventory for the Houston site. The estimated ozone production efficiency (OPE) for the industrial area in Houston indicated volatile organic compound (VOC)–limited conditions in the morning, which transitioned to nitrogen oxide (NOx)–limited conditions in the afternoon. Texas cities have complex emission scenarios, and future efforts to mitigate ozone and particulate matter may have to consider a variety of emission reduction strategies.

24 January 2024 in Atmospheric Environment
Verified
Journal Article
Closed access
FGFangzhou Guo
Fangzhou Guo
ABAlexander A.T. Bui
Alexander A.T. Bui
BSBenjamin C. Schulze
Benjamin C. Schulze
Qili DaiQili Dai
Qili Dai
SYSubin Yoon
Subin Yoon
RGRobert J. Griffin
Robert J. Griffin