Antonio Cibelli

Dr. Antonio Cibelli

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2022 in Engineering Fracture Mechanics
Verified
Journal Article
Closed access
ACAntonio Cibelli
Antonio Cibelli
Madura PathirageMadura Pathirage
Madura Pathirage
GCGianluca Cusatis
Gianluca Cusatis
LFLiberato Ferrara
Liberato Ferrara
GLGiovanni Di Luzio
Giovanni Di Luzio

1 December 2023 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
ACAntonio Cibelli
Antonio Cibelli
GLGiovanni Di Luzio
Giovanni Di Luzio
LFLiberato Ferrara
Liberato Ferrara

10 February 2025 in Composite Structures
Verified
Journal Article
Closed access
YWYilin Wang
Yilin Wang
ACAntonio Cibelli
Antonio Cibelli
JVJan Vorel
Jan Vorel
PSPhilipp Siedlaczek
Philipp Siedlaczek
JBJan Belis
Jan Belis
Roman Wan-Wendner Roman Wan-Wendner
Roman Wan-Wendner

5 February 2025 in Fibers
Verified
Journal Article
Open access
PDF file
Sushant PoudelSushant Poudel
Sushant Poudel
ACAntonio Cibelli
Antonio Cibelli
CPClementina Del Prete
Clementina Del Prete
Roman Wan-Wendner Roman Wan-Wendner
Roman Wan-Wendner
CMClaudio Mazzotti
Claudio Mazzotti
NBNicola Buratti
Nicola Buratti
The use of fibre-reinforced concrete (FRC) has been substantially increasing in the last few years, in different fields of the construction industry. Recently, many experiments have been performed to observe the short- and long-term mechanical behaviour of FRC, and several models have been formulated to capture its mechanical response. In this work, the mechanical behaviour is simulated through the Lattice Discrete Particle Model (LDPM) and its extension to fibre-reinforced cementitious composites (LDPM-F). This paper aims to provide insights into the calibration process and potential pitfalls in a case where only limited experimental data are available—in this case, unconfined uniaxial compression and three-point bending tests on different mixes of polypropylene and steel fibre-reinforced concretes. As a first step, a sensitivity analysis is performed to weight the effect of each governing mesoscale parameter on the simulated macroscale behaviour. Then, for each mix at issue, different sets of model parameters are identified as capable of accurately matching the experimental evidence. As a validation, each calibrated set is used to simulate energy absorption tests on round panels. The validation stage shows that one of the identified sets, for the FRC with polypropylene fibres, accurately matches the round panels’ response, while the others result in acceptable predictions. For the mix with steel fibres, instead, none of the sets captures the experimental results, likely due to the different post-cracking behaviour detected in fracture and energy absorption tests. Finally, a parametric study showcases how the LDPM-F might serve as tool to optimise the mix design without extensive experimental investigations.

19 November 2024 in Journal of Building Engineering
Verified
Journal Article
Open access
ACAntonio Cibelli
Antonio Cibelli
LFLiberato Ferrara
Liberato Ferrara
GLGiovanni Di Luzio
Giovanni Di Luzio

7 May 2025 in Fire and Materials
Verified
Journal Article
Open access
VVVirginia Venezia
Virginia Venezia
maria portarapillomaria portarapillo
maria portarapillo
DSDonatella de Silva
Donatella de Silva
ACAntonio Cibelli
Antonio Cibelli
GLGiuseppina Luciani
Giuseppina Luciani
ABAlmerinda Di Benedetto
Almerinda Di Benedetto
This study addresses the critical issue of fire safety in densely populated urban areas and focuses on the resilience of new and existing buildings, with an emphasis on passive fire protection materials for steel structures. Conventional fire codes are considered potentially restrictive, which has led to research in the field of performance‐based fire safety engineering (FSE). This research focuses specifically on non‐reactive passive fire protection materials, which are known to protect steel elements from high fire temperatures. Two kinds of materials, calcium silicate‐based cement (CSC) and gypsum (GP), are investigated using morphological, physicochemical, and thermal analyses in more realistic fire scenarios. Unlike standard fire curves, such as ISO 834, lower heating rates (up to 100°C/min) allowed for a more realistic assessment of the material effectiveness in protecting steel structures from fire. CSC releases only free water molecules within 150°C, resulting in a lower weight loss up to 1000°C, with endothermic transformations totaling 270 J/g. GP releases both free and bound water molecules at different temperatures and triggers several endothermic reactions (with a higher total amount of heat removed from the fire 670 J/g), which increases fire resistance. This mechanism uses the external heat generated by the fire to vaporise water, which increases the fire resistance of the material. This study links the chemical and thermal properties of passive fire protection materials to their fire performance, showing that materials with similar compositions can behave differently. This highlights the need for a new classification system based on material‐specific properties.