The auditory steady state response (ASSR) is an oscillatory brain response, which is phase locked to the rhythm of an auditory stimulus. ASSRs have been recorded in response to a wide frequency range of modulation and/or repetition, but the physiological features of the ASSRs are somewhat different depending on the modulation frequency. Recently, the 20-Hz ASSR has been emphasized in clinical examinations, especially in the area of psychiatry. However, little is known about the physiological properties of the 20-Hz ASSR, compared to those of the 40-Hz and 80-Hz ASSRs. The effects of contralateral noise on the ASSR are known to depend on the modulation frequency to evoke ASSR. However, the effects of contralateral noise on the 20-Hz ASSR are not known. Here we assessed the effects of contralateral white noise at a level of 70 dB SPL on the 20-Hz and 40-Hz ASSRs using a helmet-shaped magnetoencephalography system in 9 healthy volunteers (8 males and 1 female, mean age 31.2 years). The ASSRs were elicited by monaural 1000-Hz 5-s tone bursts amplitude-modulated at 20 and 39 Hz and presented at 80 dB SPL. Contralateral noise caused significant suppression of both the 20-Hz and 40-Hz ASSRs, although suppression was significantly smaller for the 20-Hz ASSRs than the 40-Hz ASSRs. Moreover, the greatest suppression of both 20-Hz and 40-Hz ASSRs occurred in the right hemisphere when stimuli were presented to the right ear with contralateral noise. The present study newly showed that 20-Hz ASSRs are suppressed by contralateral noise, which may be important both for characterization of the 20-Hz ASSR and for interpretation in clinical situations. Physicians must be aware that the 20-Hz ASSR is significantly suppressed by sound (e.g. masking noise or binaural stimulation) applied to the contralateral ear.
12 November 2016 in European Archives of Oto-Rhino-Laryngology
The aim of this study is to investigate the middle ear dynamic characteristics and their influence on TEOAEs in patients with middle ear disorders. The middle ear dynamic characteristics and TEOAE findings were investigated in 89 patients with middle ear disorders using the sweep frequency impedance (SFI) meter and the 1LO88 system, respectively. These patients were divided into six subcategories: tympanic membrane aberrations, otitis media with effusion, chronic otitis media, tympanic membrane perforation, otosclerosis, and ossicular chain dislocation. Details of the TEOAE frequency characteristics were compared with the individual's middle ear dynamic characteristics. TEOAE status as a function of hearing threshold and middle ear dynamic characteristics was also examined. The results showed that the middle ear dynamic characteristics in patients with middle ear disorders correlated with the TEOAE frequency characteristics and amplitudes. The hearing level and middle ear mobility were the controlling factors affecting TEOAE status. Using both non-linear and linear stimulus modes, larger TEOAE responses were obtained when the hearing level was better than 20 dB HL, and there was moderately good middle ear mobility. Moreover, TEOAEs were absent using the non-linear mode when the hearing level was worse than 30 dB HL, whereas with the linear mode, TEOAEs were recordable even with hearing losses of up to 40 dB HL in patients with middle ear disorders. A higher incidence of recordable TEOAEs was found in the subgroups with tympanic membrane abnormalities and secretory otitis media when compared with the other subgroups. No TEOAEs were recordable in patients with chronic otitis media. El objetivo de este estudio fue investigar las características dinámicas del oído medio y su influencia en las TEOAEs en pacientes con trastornos del oído medio. Se investigaron las caracteristicas dinámicas del oído medio y los hallazgos en las TEOAEs en 89 pacientes con trastornos del oído medio, usando un impedanciómetro de barrido de frecuencias (SFI) y el sistema ILO99, respectivamente. Estos pacientes fueron divididos en seis subcategorías: aberraciones de la membrana timpánica, otitis media secretrora, otitis media crónica, perforación de la membrana timpánica, otoesclerosis y dislocación de la cadena osicular. Se compararon los detalles de las características frecuenciales de las TEOAEs con las características dinámicas del oído medio de cada individuo. También se examinó el status de las TEOAEs como función del umbral auditivo y las características dinámicas del oído medio. Los resultados muestran que las características dinámicas del oído medio en pacientes con trastornos del oído medio se correlacionan con la amplitud y con las caracteristicas frecuenciales de las TEOAE. El nivel auditivo y la movilidad del oído medio fueron los factores de control que afectaron el status de las TEOAE. Se obtuvieron mejores respuestas de TEOAEs usando tanto los modos de estimulación lineares como no lineares, cuando el nivel de audición era mejor que 20 dB HL y cuando había una moderadamente buena movilidad del oído medio. Mas aún, las TEOAEs estuvieron ausentes al usar el modo no linear, cuando el nivel auditivo era inferior a 30 dB HL mientras que con el modo linear, las TEOAEs eran registrables incluso con pérdidas auditivas superiores a 40 dB HL en pacientes con trastornos del oído medio. Se encontró una incidencia mayor de TEOAEs registrables en los subgrupos con anormalidades de la membrana timpánica o con otitis media secretoria que en otros subgrupos. No se pudieron registrar TEOAEs en pacientes con otitis media crónica.
1 January 2003 in International Journal of Audiology
Diplacusis is defined as the phenomenon of hearing the same tone at different pitches in the two ears. Although binaural pitch-matching using method-of-adjustment has been employed in most studies, it is sometimes hard for subjects with impaired hearing to judge 'equal pitch' as one frequency. To resolve this problem. a modified pitch-matching test, in which the relation of pitch sensation between the two ears was assessed as a matched frequency 'range' using the randomized maximum likelihood sequential procedure, was developed. Eight subjects with unilaterally impaired hearing, as well as eight normal subjects, were examined to evaluate this new test procedure. In the present method, matched frequency is assessed as a frequency range, in which subjects cannot judge whether the pitch of the signal in one ear is higher or lower than that in the opposite ear. This method appeared to be useful for assessing the characteristics of diplacusis in subjects with impaired hearing as well as in normal subjects.