Liviu-Mihai Iacob

Mr. Liviu-Mihai Iacob


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SMSorana Mureșanu
Sorana Mureșanu
MHMihaela Hedeșiu
Mihaela Hedeșiu
LILiviu-Mihai Iacob
Liviu-Mihai Iacob
RERadu Eftimie
Radu Eftimie
EOEliza Maria Olariu
Eliza Maria Olariu
OGon behalf of Team Project Group
on behalf of Team Project Group
Background/Objectives: The integration of AI into dentistry holds promise for improving diagnostic workflows, particularly in the detection of dental pathologies and pre-radiotherapy screening for head and neck cancer patients. This study aimed to develop and validate an AI model for detecting various dental conditions, with a focus on identifying teeth at risk prior to radiotherapy. Methods: A YOLOv8 model was trained on a dataset of 1628 annotated panoramic radiographs and externally validated on 180 radiographs from multiple centers. The model was designed to detect a variety of dental conditions, including periapical lesions, impacted teeth, root fragments, prosthetic restorations, and orthodontic devices. Results: The model showed strong performance in detecting implants, endodontic treatments, and surgical devices, with precision and recall values exceeding 0.8 for several conditions. However, performance declined during external validation, highlighting the need for improvements in generalizability. Conclusions: YOLOv8 demonstrated robust detection capabilities for several dental conditions, especially in training data. However, further refinement is needed to enhance generalizability in external datasets and improve performance for conditions like periapical lesions and bone loss.

1 January 2026 in IET Image Processing
Verified
Journal Article
Open access
PDF file
LILiviu-Mihai Iacob
Liviu-Mihai Iacob
RORadin‐Darius Oniţ
Radin‐Darius Oniţ
AGAdrian Groza
Adrian Groza
AVAndrei Varan
Andrei Varan
SMSorana Mureşanu
Sorana Mureşanu
MHMihaela Hedeşiu
Mihaela Hedeşiu
Low‐dose computed tomography (LDCT) is a medical imaging modality designed to minimize ionizing radiation exposure while maintaining the ability to produce detailed cross‐sectional images. It is particularly valuable in scenarios requiring repeated imaging, such as cancer screening, follow‐up examinations or pediatric diagnostics, where reducing radiation dose is critical to patient safety. For example, to reduce noise by half, four times the radiation dose is required in the slice. The goal is to achieve post‐processed LDCT images with comparable quality to those obtained from standard‐dose CT imaging. We start with a brief overview of the CT procedures and their limitations. Then we introduce a novel denoising method based on an asymmetric integration of the ConvNeXt backbone with the U‐Net architecture. This novel approach obtained 2–3 times less noise than the original LDCT, having a 10%–20% increase in performance compared to U‐Net implementation, checked against three metrics MSE, SSIMLoss and combinations of both. The results suggest that: (i) augmenting the images with specific noise, obtained from water phantom CT scan test, while training yields superior results compared to generic noise augmentations; (ii) a larger kernel size better extracts features and (iii) a smaller kernel size was mandatory for feature reconstruction.