Rahul Gowtham Poola

Mr. Rahul Gowtham Poola

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2023 in Results in Engineering
Verified
Journal Article
Open access
RPRahul Gowtham Poola
Rahul Gowtham Poola
LPLahari Pl
Lahari Pl
SYSiva Sankar Y
Siva Sankar Y
Due to the augmented rise of COVID-19, clinical specialists are looking for fast faultless diagnosis strategies to restrict Covid spread while attempting to lessen the computational complexity. In this way, swift diagnosis techniques for COVID-19 with high precision can offer valuable aid to clinical specialists. RT- PCR test is an expensive and tedious COVID diagnosis technique in practice. Medical imaging is feasible to diagnose COVID-19 by X-ray chest radiography to get around the shortcomings of RT-PCR. Through a variety of Deep Transfer-learning models, this research investigates the potential of Artificial Intelligence -based early diagnosis of COVID-19 via X-ray chest radiographs. With 10,192 normal and 3616 Covid X-ray chest radiographs, the deep transfer-learning models are optimized to further the accurate diagnosis. The x-ray chest radiographs undergo a data augmentation phase before developing a modified dataset to train the Deep Transfer-learning models. The Deep Transfer-learning architectures are trained using the extracted features from the Feature Extraction stage. During training, the classification of X-ray Chest radiographs based on feature extraction algorithm values is converted into a feature label set containing the classified image data with a feature string value representing the number of edges detected after edge detection. The feature label set is further tested with the SVM, KNN, NN, Naive Bayes and Logistic Regression classifiers to audit the quality metrics of the proposed model. The quality metrics include accuracy, precision, F1 score, recall and AUC. The Inception-V3 dominates the six Deep Transfer-learning models, according to the assessment results, with a training accuracy of 84.79% and a loss function of 2.4%. The performance of Cubic SVM was superior to that of the other SVM classifiers, with an AUC score of 0.99, precision of 0.983, recall of 0.8977, accuracy of 95.8%, and F1 score of 0.9384. Cosine KNN fared better than the other KNN classifiers with an AUC score of 0.95, precision of 0.974, recall of 0.777, accuracy of 90.8%, and F1 score of 0.864. Wide NN fared better than the other NN classifiers with an AUC score of 0.98, precision of 0.975, recall of 0.907, accuracy of 95.5%, and F1 score of 0.939. According to the findings, SVM classifiers topped other classifiers in terms of performance indicators like accuracy, precision, recall, F1-score, and AUC. The SVM classifiers reported better mean optimal scores compared to other classifiers. The performance assessment metrics uncover that the proposed methodology can aid in preliminary COVID diagnosis.

4 June 2025 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
LPLahari PL
Lahari PL
RPRahul Gowtham Poola
Rahul Gowtham Poola
LGLeela Prasad Gorrepati
Leela Prasad Gorrepati
SYSiva Sankar Yellampalli
Siva Sankar Yellampalli
This study presents GhostYOLO, an enhanced YOLO-based model for cataract detection that incorporates GhostConv layers to offer greater accuracy, faster processing, and less memory consumption for real-time diagnosis. Initially, the performance of YOLO models, namely YOLOv5, YOLOv6, YOLOv7, and YOLOv8, was evaluated using 788 normal and 920 cataract images, with YOLOv8n emerging as the best standard model with excellent precision, speed, and efficiency. GhostYOLO models were developed to further improve speed and accuracy. GhostYoloV8n obtained the highest accuracy, speed, and lowest memory usage, while GhostYoLoV7-tiny also performed well. Incorporating GhostConv layers substantially improved cataract detection, increasing efficiency and real-time usage. Real-time tests using a Jetson Nano board demonstrated its efficiency, with 33.5 FPS in live detection, simplifying diagnosis. GhostYoloV8n, with only 1.6 million parameters, is a small but powerful cataract detection tool that allows for faster and more precise medical intervention. This study highlights the benefits of including GhostConv layers in YOLO models, making cataract diagnosis more accurate, efficient, and scalable for clinical applications.



27 December 2024 in IEEE Access
Verified
Journal Article
Open access
RPRahul Gowtham Poola
Rahul Gowtham Poola
SYSiva Sankar Yellampalli
Siva Sankar Yellampalli
The research outlines a workflow for medical image analysis and disease diagnosis through radiomics feature extraction. The dataset, consisting of chest X-ray images, was pre-processed using techniques such as denoising, resizing, and enhancement to ensure uniformity and high image quality. Advanced texture analysis methods, including Gray Level Size Zone Matrix, Gray Level Co-Occurrence Matrix, Gray Level Dependence Matrix and, Gray Level Run Length Matrix were employed to extract radiomics features. Power Spectral Density analysis using Burg, Yule Walker, and Welch techniques further enriched the understanding of frequency characteristics within the radiomics feature matrices, uncovering patterns vital for precise predictions. Diverse classifiers, including Bernoulli Naïve Bayes, Random Subspace Boost, Quadratic Discriminant, and Gradient Boosting, were employed to classify test X-rays. The performance of these classifiers was evaluated using metrics such as Cohen’s Kappa, Accuracy, Matthews Correlation Coefficient, Sensitivity, Youden’s Index, Specificity, Log Loss, and Brier Score. Among these, Gradient Boosting demonstrated superior performance across all feature sets, achieving a Cohen’s Kappa of 0.93, MCC of 0.88, Youden’s Index of 0.82, and a Log Loss of 0.27.

31 August 2023 in Research Square
Verified
Preprint
Open access
PDF file
LPLahari PL
Lahari PL
RPRahul Gowtham Poola
Rahul Gowtham Poola
SYSiva Sankar Yellampalli
Siva Sankar Yellampalli
Hardware accelerator is a specialized hardware component created to carry out particular tasks faster than a general-purpose CPU. Its goal is to expedite particular computations or processes that a general-purpose processor cannot effectively handle due to their complexity or length. Hardware accelerators play an important role in increasing the functionality and performance of electronic gadgets by allowing them to conduct complex computations. There are variety forms of hardware accelerators such as GPU’S, FPGA, ASIC’s, TPU, DSP etc., In this paper we have designed CNN Accelerator. CNN is a special hardware accelerator for speed up the calculations which are necessary for convolutional deep neural network inference and training. The main goal of CNN Accelerator is to do the calculations and enhance the functionality and energy efficiency of deep learning systems. This uses the various architectures such as convolution, activation, pooling and fully connected layer. The main block for building this accelerator is processing element [PE]. Here we have designed new processing element block which consumes less area, low power of 15% and gives high speed of 11% when compared to the existing block. CNN Accelerator is designed with the proposed processing element block, since Accelerator deals with the speed constraint. Implementation of the CNN Accelerator is done on the Artix 7 FPGA board and this consumes the area of 7186 slices and on-chip power of 100.486W. The proposed Accelerator gives high speed than earlier designs.