Dr. Tuomas Messo

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
JSJussi Sihvo
Jussi Sihvo
Daniel-Ioan StroeDaniel-Ioan Stroe
Daniel-Ioan Stroe
TMTuomas Messo
Tuomas Messo
Tomi RoinilaTomi Roinila
Tomi Roinila
Online measurements of the battery impedance provides valuable information on the battery state-of-charge and state-of-health which can be utilized for improving the safety and the performance of the associated system. The electrochemical-impedance- spectroscopy (EIS) is widely used for battery impedance measurements but it is not the most applicable solution for online measurements due to its slowness and complexity. These drawbacks can be improved using broadband signals, such as, pseudo-random-sequences (PRS), which are fast and easily implementable. However, the non- linear behavior of batteries have significant effect on the impedance measurements and the selection of the PRS signal. Majority of the PRS signals are applicable for measurements of linear systems but also signals for non-linear system identification do exist. Moreover, the reduced accuracy and signal-to-noise ratio of the PRS signals compared to the EIS make the filtering of the results as well as the amplitude design important aspects. This paper demonstrates the use of two PRS signals, the pseudo-random-binary-sequence (PRBS) and a ternary- sequence with better toleration to battery non-linear effects, with comprehensive amplitude and filtering design for battery impedance measurements. The results are referenced and validated to practical EIS measurements in various operating conditions for lithium-iron-phosphate cell.

23 July 2012 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LNLari Nousiainen
Lari Nousiainen
JPJoonas Puukko
Joonas Puukko
AMAnssi Mäki
Anssi Mäki
TMTuomas Messo
Tuomas Messo
JHJuha Huusari
Juha Huusari
TSTeuvo Suntio
Teuvo Suntio
A photovoltaic (PV) generator is internally a power-limited nonlinear current source having both constant-current- and constant-voltage-like properties depending on the operating point. This paper investigates the dynamic properties of a PV generator and demonstrates that it has a profound effect on the operation of the interfacing converter. The most important properties an input source should have in order to emulate a real PV generator are defined. These properties are important, since a power electronic substitute is often used in the validation process instead of a real PV generator. This paper also qualifies two commercial solar array simulators as an example in terms of the defined properties. Investigations are based on extensive practical measurements of real PV generators and the two commercial solar array simulators interfaced with dc-dc as well as three- and single-phase dc-ac converters.

9 June 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Tomi RoinilaTomi Roinila
Tomi Roinila
TMTuomas Messo
Tuomas Messo
ESEnrico Santi
Enrico Santi
Grid impedance and the output impedance of grid-connected inverter are important parameters for the operation of grid-connected systems, such as solar, wind, and other distributed-generation resource systems. The impedance mismatch between the grid and the interfacing circuit often generates harmonic resonances that lead to reduced power quality and even instability. Since the impedances usually vary over time as a function of many parameters, online measurements are required for stability assessment and adaptive control of the inverters. Several methods have been proposed for quick, accurate measurements of impedances, but the use of multiple-input multiple-output (MIMO) identification techniques have not been considered. Applying the MIMO techniques, different components of the inverter output impedance or grid impedance can be simultaneously measured during a single measurement cycle. Therefore, the operating conditions of the system can be kept constant during the measurements, and the overall measurement time is significantly reduced. This paper shows the use of orthogonal binary sequences to simultaneously measure the “d” and “q” components of grid-connected inverter output impedance and/or grid impedance. Experimental results based on a three-phase grid-connected inverter are presented and used to demonstrate the effectiveness of the proposed methods.

27 March 2013 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TMTuomas Messo
Tuomas Messo
JJJuha Jokipii
Juha Jokipii
JPJoonas Puukko
Joonas Puukko
TSTeuvo Suntio
Teuvo Suntio
Grid interfacing of photovoltaic generators using three-phase inverters offers the advantage of constant power flow allowing smaller capacitance values to be used in the dc-link compared to single-phase inverters. Electrolytic capacitors, used in the dc-link, are often considered to decrease reliability. Reliability could be improved by using film capacitors, but their usage is limited by high cost and low capacitance. Much research has been done to minimize the dc-link capacitance value, particularly, in the field of drives and wind turbines. It has been shown that motor drive in regenerative mode contains a right-half-plane (RHP) pole in its control dynamics having a significant effect on the required dc-link capacitance. The RHP pole can cause instability as has been observed in wind turbine applications. Photovoltaic inverters have been reported to suffer from instability of the dc-link-voltage control, but the origin of the observed problems is poorly understood. This paper shows explicitly that an RHP pole is present in the control dynamics also in photovoltaic inverters affecting the minimum required dc-link capacitance. The paper proposes a minimum value for the dc-link capacitance that is required for stable operation. Design rules are given for single- and two-stage inverters. Moreover, it is shown that a source having constant power output effectively removes the RHP pole from the dc-link-voltage control dynamics.

12 April 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Tomi RoinilaTomi Roinila
Tomi Roinila
TMTuomas Messo
Tuomas Messo
Grid impedance affects the stability and control performance of grid-connected power-electronics devices, such as inverters, used to integrate wind and solar energy. Adaptive control of such inverters, to guarantee stability under different grid conditions, requires online measurement of the grid impedance performed in real time. Wideband frequency-response-measurement techniques based on the pseudo-random binary sequence (PRBS) or impulse injection have been often applied for grid-impedance measurements. However, while using the PRBS or impulse, it is assumed that the system under study is linear. Because such an assumption does not typically hold for grid-connected systems, the measured impedances are usually prone to distortions caused by nonlinearities. This paper proposes the use of periodic ternary sequences for online grid-impedance measurements. Using appropriately designed periodic ternary signals, the linear component of the grid impedance can be identified, eliminating errors from even-order nonlinear distortions. In addition, the ternary sequences can be designed for a much wider range of sequence length compared to the conventional PRBS, enabling more efficient optimization of computing power and frequency resolution. Experimental measurements are shown from a grid-connected photovoltaic inverter.

13 April 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RLRoni Luhtala
Roni Luhtala
Tomi RoinilaTomi Roinila
Tomi Roinila
TMTuomas Messo
Tuomas Messo
Grid impedance has a major effect on the operation of inverter-connected systems, such as renewable energy sources. Stability of such system depends on the ratio of the inverter output impedance and the grid impedance at the point of common coupling. Because the grid impedance varies over time with many parameters, online grid-impedance measurement acquired in real time is most preferred method for observing the stability. Recent studies have presented methods based on multiple-input-multiple-output (MIMO) identification techniques where the stability of grid-connected system is rapidly assessed in the dq domain. In the methods, orthogonal injections are used with Fourier techniques, and the grid impedance d and q components are measured. The Nyquist stability criterion is then applied to assess the stability. This paper extends previous studies, and presents a real-time implementation for the online stability analysis using MIMO-identification methods. The practical implementation is discussed in detail and experimental results based on a grid-connected threephase inverter are provided to demonstrate the effectiveness of the methods.