6 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FFFranz Konstantin Fuss
Franz Konstantin Fuss
Asliza AhmadAsliza Ahmad
Asliza Ahmad
ATAdin Tan
Adin Tan
RRRizal Razman
Rizal Razman
Yehuda WeizmanYehuda Weizman
Yehuda Weizman
Hard-shell thoracolumbar sacral orthoses (TLSOs) are used for treating idiopathic scoliosis, a deformation of the spine with a sideways curvature. The pressure required inside the TLSO for ideal corrective results remains unclear. Retrofitting TLSOs with commercially available pressure measurement systems is expensive and can only be performed in a laboratory. The aim of this study was to develop a cost-effective but accurate pressure sensor system for TLSOs. The sensor was built from a piezoresistive polymer, placed between two closed-cell foam liners, and evaluated with a material testing machine. Because foams are energy absorbers, the pressure-conductance curve was affected by hysteresis. The sensor was calibrated on a force plate with the transitions from loading to unloading used to establish the calibration curve. The root mean square error was 12% on average within the required pressure range of 0.01–0.13 MPa. The sensor reacted to the changing pressure during breathing and different activities when tested underneath a chest belt at different tensions. The peak pressure reached 0.135 MPa. The sensor was further tested inside the scoliosis brace during different activities. The measured pressure was 0.014–0.124 MPa. The results from this study enable cheaper and mobile systems to be used for clinical studies on the comfort and pressure of braces during daily activities.

24 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Yehuda WeizmanYehuda Weizman
Yehuda Weizman
Oren TiroshOren Tirosh
Oren Tirosh
FFFranz Konstantin Fuss
Franz Konstantin Fuss
ATAdin Tan
Adin Tan
Erich RutzErich Rutz
Erich Rutz
Spasticity is a disabling characteristic of neurological disorders, described by a velocity-dependent increase in muscle tone during passive stretch. During the last few years, many studies have been carried out to assess spasticity using wearable IMU (inertial measurements unit) sensors. This review aims to provide an updated framework of the current research on IMUs wearable sensors in people living with spasticity in recent studies published between 2017 and 2021. A total of 322 articles were screened, then finally 10 articles were selected. Results show the lack of homogenization of study procedures and missing apparatus information in some studies. Still, most studies performed adequately on measures of reporting and found that IMUs wearable data was successful in their respective purposes and goals. As IMUs estimate translational and rotational body motions, we believe there is a strong potential for these applications to estimate velocity-dependent exaggeration of stretch reflexes and spasticity-related characteristics in spasticity. This review also proposes new directions of research that should be challenged by larger study groups and could be of interest to both researchers as well as clinicians. The use of IMUs to evaluate spasticity is a promising avenue to provide an objective measurement as compared to non-instrumented traditional assessments.

30 December 2021 in COVID
Verified
Journal Article
Open access
PDF file
FFFranz Konstantin Fuss
Franz Konstantin Fuss
Yehuda WeizmanYehuda Weizman
Yehuda Weizman
ATAdin Tan
Adin Tan
For fighting the COVID-19 pandemic, countries used control measures of different severity, from “relaxed” to lockdown. Drastic lockdown measures are considered more effective but also have a negative impact on the economy. When comparing the financial value of lost lives to the losses of an economic disaster, the better option seems to be lockdown measures. We developed a new parameter, the effectiveness of control measures, calculated from the 2nd time derivative of daily case data, for 92 countries, states and provinces. We compared this parameter, and also the mortality during and after the effective phase, for countries with and without lockdowns measures by means of the Mann–Whitney test. We did not find any statistically significant difference in the effectiveness between countries with and without lockdowns (p > 0.76). There was also no significant difference in mortality during the effective phase (p > 0.1); however, a significant difference after the effective phase, with higher mortality for lockdown countries, was identified. The effectiveness correlated well with a parameter derived from the reproductive number (R2 = 0.9480). The average duration of the effective phase was 17.3 ± 10.5 days. The results indicated that lockdown measures are not necessarily superior to relaxed measures, which in turn are not necessarily a recipe for failure. Relaxed measures are, however, more economy-friendly.

1 January 2022 in Clinical Biomechanics
Verified
Journal Article
Closed access
ATAdin Tan
Adin Tan
YWYehuda Weizman
Yehuda Weizman
JNJaap J. Van Netten
Jaap J. Van Netten
FFFranz Konstantin Fuss
Franz Konstantin Fuss

27 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Yehuda WeizmanYehuda Weizman
Yehuda Weizman
ATAdin Tan
Adin Tan
FFFranz Konstantin Fuss
Franz Konstantin Fuss
The SARS-CoV-2 pandemic resulted in approximately 7 million deaths and impacted 767 million individuals globally, primarily through infections. Acknowledging the impactful influence of sedentary behaviors, particularly exacerbated by COVID-19 restrictions, a substantial body of research has emerged, utilizing wearable sensor technologies to assess these behaviors. This comprehensive review aims to establish a framework encompassing recent studies concerning wearable sensor applications to measure sedentary behavior parameters during the COVID-19 pandemic, spanning December 2019 to December 2022. After examining 582 articles, 7 were selected for inclusion. While most studies displayed effective reporting standards and adept use of wearable device data for their specific research aims, our inquiry revealed deficiencies in apparatus accuracy documentation and study methodology harmonization. Despite methodological variations, diverse metrics, and the absence of thorough device accuracy assessments, integrating wearables within the pandemic context offers a promising avenue for objective measurements and strategies against sedentary behaviors.

13 February 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
Yehuda WeizmanYehuda Weizman
Yehuda Weizman
ATAdin Tan
Adin Tan
FFFranz Konstantin Fuss
Franz Konstantin Fuss
Footwear-based wearable applications are relevant to numerous fields and have great commercial and clinical potential. However, scientifically validated, reliable data on these devices is largely missing. Centre of pressure (COP) is an important and common factor for measuring balance and gait and hence the validity of such devices is essential for reading accurate data. This study aims to investigate COP accuracy of an existing system, Pedar (PE), and a newly designed Smart Insole (SI) using a force plate (FP). This was done by means of COP data noise (R2), and gradient of the fit function (k). For the SI, the maximum COPx and COPy data achieved R2 values of 0.7837 and 0.9368 and k values of 0.8867 and 0.8538 respectively when compared with the FP. Conversely, the Pedar achieved R2 values of 0.8409 and 0.9401 and k values of 1.0492 and 1.08 when compared with the FP respectively.