An innovative method for the quantification of corticosterone in the urine of C57BL/6J mice by liquid chromatography-electrospray ionization-tandem mass spectrometry was developed. Unconjugated and glucuronidated corticosterone was detected in the urine samples using enzymatic hydrolysis following liquid–liquid extraction. After optimization of the extraction protocol and LC-MS/MS parameters, we performed a validation study using a representative urine pool of C57BL/6J and Naval Medical Research Institute mice. The method shows good linearity (1–5000 fmol/µL) and the calculated limit of quantification amounts to 0.823 fmol/µL. Both intra-day and inter-day variation was ≤10%, while their recoveries amounted to 90.4–110.6% and 99.8%, respectively. Twenty-four hour urine collection of C57BL/6J mice restrained in two different metabolic cage types for two times was used to test the validated method. To control the hydration level of mice, the corticosterone concentration in their urine was normalized to urinary creatinine concentration. Our LC-MS/MS method represents a highly specific analytical tool for the quantification of corticosterone levels in urine samples, assisting in non-invasive monitoring of acute stress levels in laboratory mice.
Biomedical research relies on scientifically validated tools to assess pain, suffering, and distress in laboratory animals to ensure their well-being. In mice, the most frequently used laboratory animals, the Mouse Grimace Scale (MGS) provides a reliable tool for the assessment of facial expression changes caused by impaired well-being. However, no automated tool can yet reliably assess all features of the MGS across different mouse strains under varying experimental or housing conditions in real-time, as the variability present in recorded image datasets poses substantial challenges for computer vision models. Despite this technical difficulty, variability across subsets in terms of mouse strain, treatments, laboratory, and image acquisition setup is essential for paving the way toward MGS assessment under non-standardized conditions in the home cage rather than standardized cage-side recording setups. Against this background, a large and diverse dataset containing five subsets is introduced and a deep learning model was trained to predict the average MGS scores ranging between 0 and 2. It achieved a root mean squared error (RMSE) of 0.26 when trained on all subsets of the dataset, outperforming the average human rater in terms of error magnitude. The correlation between human raters and automated MGS scores was very high (Pearson’s r=0.85). In the cross-dataset evaluation, one subset was excluded from training and used for testing the model. This approach yielded higher errors compared to models trained and tested on the same subsets. A model restricted to the feature of orbital tightening showed lower performance than one trained on all facial features of the MGS. Overall, the most reliable model for predicting average MGS scores for a novel dataset is the one trained on the combined subsets. Performance may be further enhanced by fine-tuning the model using human-generated MGS scores for a portion of the novel subset.