Omiya Hassan

Dr. Omiya Hassan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2025 in Symmetry
Verified
Journal Article
Open access
PDF file
IUIkteder Akhand Udoy
Ikteder Akhand Udoy
OHOmiya Hassan
Omiya Hassan
Artificial intelligence (AI) is playing a dominant role in advancing heart failure detection and diagnosis, significantly furthering personalized healthcare. This review synthesizes AI-driven innovations by examining methodologies, applications, and outcomes. We investigate the integration of machine learning algorithms, diverse datasets including electronic health records (EHRs), medical records, imaging data, and clinical notes, deep learning models, and neural networks to enhance diagnostic accuracy. Key advancements include prediction models that leverage real-time data from wearable devices alongside state-of-the-art AI systems trained on patient data from hospitals and clinics. Notably, recent studies have reported diagnostic accuracies ranging from 86.7% to as high as 99.9%, with sensitivity and specificity values often exceeding 97%, underscoring the potential of these AI systems to improve early detection and clinical decision-making substantially. Our review further explores the impact of symmetry and asymmetry in model design, highlighting that symmetric architectures like U-Net offer computational efficiency and structured feature extraction. In contrast, asymmetric models improve the sensitivity to rare conditions and subtle clinical patterns. Incorporating these deep learning (DL) methods in anomaly detection and disease progression modeling further reinforces their positive impact on diagnostic accuracy and patient outcomes. Furthermore, this review identifies challenges in current AI applications, such as data quality, algorithmic transparency, model bias, and evaluation metrics, while outlining future research directions, including integrating generative models, hybrid architectures, and explainable AI techniques to optimize clinical practice.

25 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
OHOmiya Hassan
Omiya Hassan
TPTanmoy Paul
Tanmoy Paul
NANazmul Amin
Nazmul Amin
TTTwisha Titirsha
Twisha Titirsha
RTRushil Thakker
Rushil Thakker
Syed IslamSyed Islam
Syed Islam
This paper presents the design of an optimized hardware-based neural network (NN) called a Shift-Accumulate Binarized Neural Network (SABiNN). SABiNN is employed in detecting respiratory-related diseases such as sleep apnea (SA) among adults. Initially, a 3-hidden layer-based NN model was trained, validated, and tested with open-source apnea PSG datasets collected from the PhysioNET databank. Single lead ECG and pulse oximeter data were collected, pre-processed, and digitized for network training. The NN was later transformed into SABiNN, demonstrating model accuracy of 81.5% (CI: ± 3.5) with an energy efficiency of 5mJ on reprogrammable hardware. The precision rate of the model was further increased by re-designing the XNOR gate of the multiply-accumulate (MAC) operation with NAND gate-based XNOR. This re-design process significantly improved the overall model’s classification and precision. Further expansion of SABiNN was carried out to achieve a higher accuracy rate (over 88%) which was designed on the CMOS platform using a 130 nm open-source process design kit (PDK) developed by Google and Skywater. The proposed model on the CMOS platform utilized a chip area of 0.16 mm 2 and showcased an energy efficiency of 1pJ. A total of ~11k CMOS cells with two 16-bit input and one 1-bit output pins were utilized to realize the SABiNN on CMOS. The success of this design technique can be leveraged in developing a fully system-on-a-chip (SoC) integrated wearable system for sleep apnea detection.

10 January 2022 in Journal of Signal Processing Systems
Verified
Journal Article
Closed access
PDF file
OHOmiya Hassan
Omiya Hassan
TPTanmoy Paul
Tanmoy Paul
MSMaruf Hossain Shuvo
Maruf Hossain Shuvo
DPDilruba Parvin
Dilruba Parvin
RTRushil Thakker
Rushil Thakker
SISyed Kamrul Islam
Syed Kamrul Islam

1 May 2020
Verified
Conference Paper
Closed access
SSSamira Shamsir
Samira Shamsir
OHOmiya Hassan
Omiya Hassan
Syed IslamSyed Islam
Syed Islam
The paper presents development of a smart infant monitoring system using multiple non-invasive sensors to detect various physiological functions. The system can evaluate different physiological activities such as respiration, movement, noise, position, as well as ambient temperature, and humidity. By processing the acquired data from different sensor modules, the system can generate alarm signals for adverse situations such as the occurrence of apnea, seizure, or noisy and uncomfortable environmental conditions. The system will also be able to detect critical respiratory conditions by analyzing breathing data and saturated blood oxygen level (SpO2) using machine learning (ML) models such as neural networks. The proposed system allows the caregiver to monitor the condition of the patient from a remote location by implementing wireless communication with a remote computer or a cell phone.

3 April 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
TPTanmoy Paul
Tanmoy Paul
OHOmiya Hassan
Omiya Hassan
CMChristina McCrae
Christina McCrae
Syed IslamSyed Islam
Syed Islam
AMAbu Mosa
Abu Mosa
Obstructive sleep apnea (OSA) is a common disorder characterized by disrupted breathing during sleep, leading to serious health consequences such as daytime fatigue, hypertension, metabolic issues, and cardiovascular disease. Polysomnography (PSG) is the standard diagnostic method but is costly and uncomfortable for patients, which has led to interest in artificial intelligence (AI) for automated OSA detection. To develop an explainable AI model that utilizes electrocardiogram (ECG) and blood oxygen saturation (SpO2) data for real-time apnea detection, providing visual explanations to enhance interpretability and support clinical decisions. It emphasizes giving visual explanations to show how specific segments of the signal contribute to the AI’s conclusions. Furthermore, it explores the combination of individual models to improve detection accuracy. The fusion of individual models demonstrates an enhanced performance in detection accuracy. Visual explanations for AI decisions highlight the importance of certain signal features, making the model’s operations transparent to healthcare providers. The proposed AI model addresses the crucial need for transparent and interpretable AI in healthcare. By providing real-time, explainable OSA detection, this approach represents a significant advancement in the field, potentially improving patient care and aiding in the early identification and management of OSA.

8 November 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
TPTanmoy Paul
Tanmoy Paul
OHOmiya Hassan
Omiya Hassan
CMChristina McCrae
Christina McCrae
Syed IslamSyed Islam
Syed Islam
AMAbu Mosa
Abu Mosa
Background: Obstructive sleep apnea is a sleep disorder that is linked to many health complications and can even be lethal in its severe form. Overnight polysomnography is the gold standard for diagnosing apnea, which is expensive, time-consuming, and requires manual analysis by a sleep expert. Artificial intelligence (AI)-embedded wearable device as a portable and less intrusive monitoring system is a highly desired alternative to polysomnography. However, AI models often require substantial storage capacity and computational power for edge inference which makes it a challenging task to implement the models in hardware with memory and power constraints. Methods: This study demonstrates the implementation of depth-wise separable convolution (DSC) as a resource-efficient alternative to spatial convolution (SC) for real-time detection of apneic activity. Single lead electrocardiogram (ECG) and oxygen saturation (SpO2) signals were acquired from the PhysioNet databank. Using each type of convolution, three different models were developed using ECG, SpO2, and model fusion. For both types of convolutions, the fusion models outperformed the models built on individual signals across all the performance metrics. Results: Although the SC-based fusion model performed the best, the DSC-based fusion model was 9.4, 1.85, and 11.3 times more energy efficient than SC-based ECG, SpO2, and fusion models, respectively. Furthermore, the accuracy, precision, and specificity yielded by the DSC-based fusion model were comparable to those of the SC-based individual models (~95%, ~94%, and ~94%, respectively). Conclusions: DSC is commonly used in mobile vision tasks, but its potential in clinical applications for 1-D signals remains unexplored. While SC-based models outperform DSC in accuracy, the DSC-based model offers a more energy-efficient solution with acceptable performance, making it suitable for AI-embedded apnea detection systems.