This work describes a methodology for the definition of indoor air quality monitoring plans in schools and above all to improve the knowledge and evaluation of the indoor concentration levels of some chemical pollutants. The aim is to guide interventions to improve the health of students and exposed staff connected with the activities carried out there. The proposed methodology is based on the simultaneous study of chemical (indoor/outdoor PM2.5, NO2, CO2) and physical (temperature, humidity) parameters by means of automatic analyzers coupled with gaseous compounds (benzene, toluene, ethylbenzene, xylenes, formaldehyde and NO2) sampled by denuders. The important novelty is that all the data were collected daily in two different situations, i.e., during school activities and no-school activities, allowing us to evaluate the exposure of each student or person. The different behaviors of all the measured pollutants during the two different situations are reported and commented on. Finally, a statistical approach will show how the investigated compounds are distributed around the two components of combustion processes and photochemical reactions.
Fourteen volatile organic compounds (VOCs)—twelve hydrocarbons and two organochlorine compounds—were monitored both outdoors and indoors for three years at one site in Rome. Results showed that 118 out of 168 indoor seasonal mean values were higher than the corresponding outdoor concentrations. The most relevant source of outdoor hydrocarbons was automotive exhaust emissions. Due to the enforcement of various measures to protect health and the environment, outdoor levels of monoaromatic hydrocarbons decreased about ten fold over 15 years, and aliphatic hydrocarbons also decreased. With the decrease in these outdoor concentrations, indoor air sources are likely to be more relevant for indoor air exposures. Winter outdoor values for monoaromatic hydrocarbons were generally markedly higher than the summer ones. The gradual replacement of the current fleet of circulating cars with new cars complying with EURO 5 standards, further reducing hydrocarbon emissions, may possibly lead to an increase in the observed indoor/outdoor ratios. It is indeed more difficult to remove indoor sources, some of which are still unknown.
Indoor air quality (IAQ) is a crucial priority, especially since people spend most of their time indoors. Indoor air can be more polluted than outdoor air due to sources such as building materials, cleaning products, and heating systems. This condition can affect health and productivity, especially in schools and work environments. Students spend about a third of their day in classrooms, and studies have shown that poor IAQ can cause respiratory and allergic problems, especially among children, who are more vulnerable. Poor ventilation and excessive CO2 concentration are indicators of suboptimal indoor air quality, which can lead to symptoms such as headaches, fatigue, and worsening asthma. In Italy, the lack of specific legislation on indoor air quality in schools is a problem, but improved ventilation, both natural and mechanical, and monitoring of CO2 levels are recommended to prevent negative health consequences. This paper aims to describe a methodology to improve IAQ in schools. The paper discusses the results of a study conducted on CO2 and PM10 levels measured in real time in cold season (Nov–Mar) in different classrooms of primary and secondary schools present in a large Italian urban area in order to understand the IAQ state and identify possible improvement actions.