Anne Saris

Mrs. Anne Saris

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
ASAnne Saris
Anne Saris
HHHendrik H.G. Hansen
Hendrik H.G. Hansen
SFStein Fekkes
Stein Fekkes
JMJan Menssen
Jan Menssen
MNMaartje M. Nillesen
Maartje M. Nillesen
CKChris L. de Korte
Chris L. de Korte

7 September 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ASAnne Saris
Anne Saris
HHHendrik H. G. Hansen
Hendrik H. G. Hansen
SFStein Fekkes
Stein Fekkes
MNMaartje M. Nillesen
Maartje M. Nillesen
MRMarcel C. M. Rutten
Marcel C. M. Rutten
CKChris L. de Korte
Chris L. de Korte
Conventional color Doppler imaging is limited, since it only provides velocity estimates along the ultrasound beam direction for a restricted field of view at a limited frame rate. High-frame-rate speckle tracking, using plane wave transmits, has shown potential for 2-D blood velocity estimation. However, due to the lack of focusing in transmit, image quality gets reduced, which hampers speckle tracking. Although ultrafast imaging facilitates improved clutter filtering, it still remains a major challenge in blood velocity estimation. Signal dropouts and poor velocity estimates are still present for high beam-to-flow angles and low blood flow velocities. In this paper, ultrafast plane wave imaging was combined with multiscale speckle tracking to assess the 2-D blood velocity vector in a common carotid artery (CCA) flow field. A multiangled plane wave imaging sequence was used to compare the performance of displacement compounding, coherent compounding, and compound speckle tracking. Zero-degree plane wave imaging was also evaluated. The performance of the methods was evaluated before and after clutter filtering for the large range of velocities (0-1.5 m/s) that are normally present in a healthy CCA during the cardiac cycle. An extensive simulation study was performed, based on a sophisticated model of the CCA, to investigate and evaluate the performance of the methods at different pulse repetition frequencies and signal-to-noise levels. In vivo data were acquired of a healthy carotid artery bifurcation to support the simulation results. In general, methods utilizing compounding after speckle tracking, i.e., displacement compounding and compound speckle tracking, were least affected by clutter filtering and provided the most robust and accurate estimates for the entire velocity range. Displacement compounding, which uses solely axial information to estimate the velocity vector, provided most accurate velocity estimates, although it required sufficiently high pulse repetition frequencies in high blood velocity phases and reliable estimates for all acquisition angles. When this latter requirement was not met, compound speckle tracking was most accurate, because it uses the possibility to discard angular velocity estimates corrupted by clutter filtering. Similar effects were observed for in vivo data obtained at the carotid artery bifurcation. Investigating a combination of these two compounding techniques is recommended for future research.

25 August 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SFStein Fekkes
Stein Fekkes
ASAbigail E. S. Swillens
Abigail E. S. Swillens
HHHendrik H. G. Hansen
Hendrik H. G. Hansen
ASAnne Saris
Anne Saris
MNMaartje M. Nillesen
Maartje M. Nillesen
CKChris L. de Korte
Chris L. de Korte
Three-dimensional (3-D) strain estimation might improve the detection and localization of high strain regions in the carotid artery (CA) for identification of vulnerable plaques. This paper compares 2-D versus 3-D displacement estimation in terms of radial and circumferential strain using simulated ultrasound (US) images of a patient-specific 3-D atherosclerotic CA model at the bifurcation embedded in surrounding tissue generated with ABAQUS software. Global longitudinal motion was superimposed to the model based on the literature data. A Philips L11-3 linear array transducer was simulated, which transmitted plane waves at three alternating angles at a pulse repetition rate of 10 kHz. Interframe (IF) radio-frequency US data were simulated in Field II for 191 equally spaced longitudinal positions of the internal CA. Accumulated radial and circumferential displacements were estimated using tracking of the IF displacements estimated by a two-step normalized cross-correlation method and displacement compounding. Least-squares strain estimation was performed to determine accumulated radial and circumferential strain. The performance of the 2-D and 3-D methods was compared by calculating the root-mean-squared error of the estimated strains with respect to the reference strains obtained from the model. More accurate strain images were obtained using the 3-D displacement estimation for the entire cardiac cycle. The 3-D technique clearly outperformed the 2-D technique in phases with high IF longitudinal motion. In fact, the large IF longitudinal motion rendered it impossible to accurately track the tissue and cumulate strains over the entire cardiac cycle with the 2-D technique.

9 May 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SFStein Fekkes
Stein Fekkes
ASAnne Saris
Anne Saris
MNMaartje M. Nillesen
Maartje M. Nillesen
JMJan Menssen
Jan Menssen
HHHendrik Hansen
Hendrik Hansen
CKChris L. de Korte
Chris L. de Korte
Plaque strain and blood vector velocity imaging of stenosed arteries are expected to aid in diagnosis and prevention of cerebrovascular disease. Ultrafast plane wave imaging enables simultaneous strain and velocity estimation. Multiple ultrasound vendors are introducing high-frequency ultrasound probes and systems. This paper investigates whether the use of high-frequency ultrafast ultrasound is beneficial for assessing blood velocities and strain in arteries. The performance of strain and blood flow velocity estimation was compared between a high-frequency transducer (MS250, fc = 21 MHz) and a clinically utilized transducer (L12-5, fc = 9 MHz). Quantitative analysis based on straight tube phantom experiments revealed that the MS250 outperformed the L12-5 in the superficial region: low velocities near the wall were more accurately estimated and wall strains were better resolved. At greater than 2-cm echo depth, the L12-5 performed better due to the high attenuation of the MS250 probe. Qualitative comparison using a perfused patient-specific carotid bifurcation phantom confirmed these findings. Thus, in conclusion, for strain and blood velocity estimation for depths up to ~2 cm, a high-frequency probe is recommended.

13 March 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ASAnne Saris
Anne Saris
SFStein Fekkes
Stein Fekkes
MNMaartje M. Nillesen
Maartje M. Nillesen
HHHendrik Hansen
Hendrik Hansen
CKChris L. De Korte
Chris L. De Korte
This paper presents a framework for motion estimation in ultrafast ultrasound data. It describes a novel approach for determining the sampling grid for ultrafast data based on the system’s point-spread-function (PSF). As a consequence, the cross-correlation functions (CCF) used in the speckle tracking (ST) algorithm will have circular-shaped peaks, which can be interpolated using a 2D interpolation method to estimate subsample displacements. Carotid artery wall motion and parabolic blood flow simulations together with rotating disk experiments using a Verasonics Vantage 256 are used for performance evaluation. Zero-degree plane wave data were acquired using an ATL L5-12 (fc = 9 MHz) transducer for a range of pulse repetition frequencies (PRFs), resulting in 0–600 µm inter-frame displacements. The proposed methodology was compared to data beamformed on a conventionally spaced grid, combined with the commonly used 1D parabolic interpolation. The PSF-shape-based beamforming grid combined with 2D cubic interpolation showed the most accurate and stable performance with respect to the full range of inter-frame displacements, both for the assessment of blood flow and vessel wall dynamics. The proposed methodology can be used as a protocolled way to beamform ultrafast data and obtain accurate estimates of tissue motion.

22 January 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
JRJanna Ruisch
Janna Ruisch
JBJoosje M. K. de Bakker
Joosje M. K. de Bakker
MHMajorie van Helvert
Majorie van Helvert
EJErik Groot Jebbink
Erik Groot Jebbink
SHSuzanne Holewijn
Suzanne Holewijn
ASAnne Saris
Anne Saris
Locally disturbed blood flow patterns are known to create an atherogenic environment, in particularly in the presence of other cardiovascular risk factors. Given the geometry of a healthy carotid artery, complex flow patterns are expected to be present. This study aims to characterize (complex) blood flow patterns and estimate flow-derived parameters in the carotid bifurcation of healthy subjects. Ultrasound-based velocity vector imaging (US-VVI) was acquired in the carotid bifurcation of twenty healthy subjects. Hemodynamic parameters, including temporal velocity profile, vector complexity, vortex presence and wall shear stress, were derived and compared between two age groups (20-30 and 65-75 years). Lower velocities and higher vector complexity values were observed in the older age group for all timepoints. The highest presence of vortices was observed during the systolic deceleration, which was more exposed in younger subjects (5 out of 10) compared to older subjects (3 out of 9). A quick build-up and consequent resolving of the vortices was reflected by the relatively short vortex duration, with a vortex presence of 11.4% (7.9-15.6) and 13.1% (5.9-18.6) as percentage of the cardiac cycle in younger and older subjects, respectively. Larger WSS estimates, represented as median along the complete vessel wall, were found in the younger subjects at all timestamps, except at systolic deceleration. In conclusion, the presence of complex flow patterns was confirmed in healthy subjects and multiple flow-derived hemodynamic parameters were evaluated in two age groups, providing an insight into age-related differences in hemodynamics. Aging seemed to result in higher vector complexities, whereas the presence of recirculating flow is less in older subjects.