This study was aimed to compare two electroencephalogram (EEG) analysis methods, spectral asymmetry index (SASI) and Higuchi’s fractal dimension (HFD), for detection of depression. Linear SASI method is based on evaluation of the balance of powers in two EEG frequency bands in one channel selected higher and lower than the alpha band spectrum maximum. Nonlinear HFD method calculates fractal dimension directly in the time domain. The resting EEG signals of 17 depressive patients and 17 control subjects were used as a database for calculations. SASI values were positive for depressive and negative for control group (). SASI provided the true detection rate of 88% in the depressive and 82% in the control group. The calculated HFD values detected a small (3%) increase with depression (). HFD provided the true detection rate of 94% in the depressive group and 76% in the control group. The rate of correct indication in the both groups was 85% using SASI or HFD. Statistically significant variations were not revealed between hemispheres (). The results indicated that the linear EEG analysis method SASI and the nonlinear HFD method both demonstrated a good sensitivity for detection of characteristic features of depression in a single-channel EEG.
13 November 2009 in Medical & Biological Engineering & Computing
Purpose: The aim of this study was to evaluate the effect of microwaves modulated at different frequencies on human electroencephalographic (EEG) rhythms. Materials and methods: Thirteen healthy volunteers were exposed to microwaves (450 MHz) pulse-modulated at frequencies of 7, 14 and 21 Hz. The field power density at the scalp was 0.16 mW/cm2. Our experimental protocol consisted of two five-cycle (1 min on and 1 min off) series of exposures at fixed modulation frequencies. A relative change in the EEG power with and without exposure was used as a quantitative measure. EEG frequencies recorded in the theta (4 – 6.8 Hz), alpha (8 – 13 Hz), beta1 (15 – 20 Hz), and beta2 (22 – 38 Hz) bands were analyzed. Results: Modulated microwaves caused an increase in the average EEG alpha (17%) and beta (7%) power but the theta rhythm remained unaffected. Increases in the EEG alpha and beta power were statistically significant during the first half-period of the exposure interval (30 s) at the modulation frequencies of 14 and 21 Hz. Differences were found in individual sensitivity to exposure. Increases in the EEG beta power appeared statistically significant in the case of four subjects. Conclusions: Our findings suggest that the effect of the 450 MHz microwave radiation modulated at 7, 14 and 21 Hz varies depending on the modulation frequency. The microwave exposure modulated at 14 and 21 Hz enhanced the EEG power in the alpha and beta frequency bands, whereas no enhancement occurred during exposure to the modulation frequency of 7 Hz.