Electrocardiogram (ECG) acquisition is easily contaminated by interferences, and denoising is the most important task in ECG detection. Variational mode decomposition (VMD) algorithm is widely used in ECG denoising, which can overcome mode aliasing between intrinsic mode function components existed in the traditional empirical mode decomposition (EMD) algorithm, but the mode decomposition number K and penalty factor α in VMD must be optimized to obtain the best signal decomposition accuracy. This paper proposes an improved VMD denoising algorithm that overcomes the shortcomings of slow parameter selection and poor generalization in the traditional VMD algorithm. The algorithm presented firstly adopts EMD algorithm to remove the low-frequency baseline drift noise, and then employs the adaptive particle swarm optimization algorithm to optimize the parameter pair ( K , α) for VMD. To validate the denoising performance of the improved VMD algorithm, the No.103 record from the MIT arrhythmia database is first selected as the pure ECG signal, then both 20dB Gaussian white noises and 0.3 Hz baseline drift are added to simulate the noisy ECG signal. Second, the ECG signals of nine subjects are collected by a customized ECG detection platform based on AD8232 and ADALM1000. The ECG denoising results in simulation and actual experiments show that the improved VMD algorithm achieves the highest signal-to-noise ratio, correlation coefficient and minimum mean square error compared with the traditional EMD and VMD algorithm, which demonstrates the proposed denoising algorithm has stronger denoising ability and better retains morphological characteristics of the original ECG signals.
10 October 2013 in IEEE Transactions on Power Systems
This paper focuses on the accurate frequency estimation of power signals corrupted by a stationary white noise. The noneven item interpolation FFT based on the triangular self-convolution window is described. A simple analytical expression for the variance of noise contribution on the frequency estimation is derived, which shows the variances of frequency estimation are proportional to the energy of the adopted window. Based on the proposed method, the noise level of the measurement channel can be estimated, and optimal parameters (e.g., sampling frequency and window length) of the interpolation FFT algorithm that minimize the variances of frequency estimation can thus be determined. The application in a power quality analyzer verified the usefulness of the proposed method.
Portable bioimpedance spectroscopy (BIS) devices are of great value for monitoring the pathological status of biological tissues in clinical and home environments. The two traditional techniques for measuring complex bioimpedance, the bridge method and quadrature demodulation method, are either time-consuming or often associated with high cost, high power consumption, and large board space, and therefore are not ideally suitable for designing a portable device for BIS measurement. This paper describes a novel design of a portable BIS device based on the magnitude-ratio and phase-difference detection method and its implementation using the newest generation of analog electronic products which greatly decrease the complexity of both hardware and software. In order to improve the accuracy of the device, a three-reference calibration algorithm was applied. Experimental sweep-frequency measurements on RC circuits were carried out to preliminarily evaluate the performances of the device. The results obtained by the device were found to be in good agreement with the results measured by a commercial impedance analyzer HP4194, with an overall mean error of 0.014% in magnitude and 0.136 degrees in phase over a frequency range of 20 kHz to 1 MHz.
Multisine signal with a low crest factor (CF) can bring a high signal-to-noise ratio for fast frequency response function (FRF) estimation. Synthesis of a low CF multisine with the given amplitude spectrum depends on optimum selection of the initial phases of its cosinusoidal components. The solutions investigated can be generally divided into two branches: (1) the analytical method based on direct formula calculation; and (2) the numerical method based on iterative computations. The analytical method works well only for an equidistant and flat amplitude spectrum, while the numerical method can generally output better results, even for a sparse or non-flat spectrum, but the number of iterations might be huge. This paper presents an improved CF minimization algorithm to synthesize multisine signals based on the combination of the previous Schroeder analytical method and the Van der Ouderaa (VDO) iteration procedure. The improved algorithm adopts the Schroder phases as the iterative initial phases, and employs a logarithmic clip function of the iterative index i in the VDO iteration procedure. Comprehensive experiments of multisine synthesis on three types of cosinusoidal amplitude spectra are performed, and the resulting CFs remain the lowest level in all cases compared with the earlier methods. The proposed algorithm provides a fast and efficient solution to synthesize multisine with the lowest CF for an arbitrary user-prescribed spectrum.
The Cole function is widely used in bioimpedance spectroscopy (BIS) applications. Fitting the measured BIS data onto the model and then extracting the Cole parameters (R0, R∞, α and τ) is a common practice. Accurate extraction of the Cole parameters from the measured BIS data has great significance for evaluating the physiological or pathological status of biological tissue. The traditional least-squares (LS)-based curve fitting method for Cole parameter extraction is often sensitive to noise or outliers and becomes non-robust. This paper proposes an improved Cole parameter extraction based on the least absolute deviation (LAD) method. Comprehensive simulation experiments are carried out and the performances of the LAD method are compared with those of the LS method under the conditions of outliers, random noises and both disturbances. The proposed LAD method exhibits much better robustness under all circumstances, which demonstrates that the LAD method is deserving as an improved alternative to the LS method for Cole parameter extraction for its robustness to outliers and noises.
3 June 2020 in IEEE Transactions on Power Delivery
Voltage sag is one of the most prominent power quality problems in electric power system. Accurate estimation of voltage sag parameters is an important reference for electric utilities and users to evaluate power quality. In this paper, a novel algorithm based on modified S transform with digital prolate spheroidal window (DPSW) is proposed to achieve accurate detection of voltage sag. The DPSW and its time-frequency characteristics are firstly detailed. Then, the construction and performance of modified S transform with DPSW are given. Since DPSW has superior time-frequency distribution, characteristics of voltage sag signal, such as sag depth, duration, and phase jump, can be obtained by analyzing the two-dimensional complex matrix after the modified S transform with DPSW. Simulation and experimental results verify the accuracy and validity of the proposed algorithm.