AC and dc microgrids (MGs) are key elements for integrating renewable and distributed energy resources as well as distributed energy-storage systems. In the last several years, efforts toward the standardization of these MGs have been made. In this sense, this paper presents the hierarchical control derived from ISA-95 and electrical dispatching standards to endow smartness and flexibility to MGs. The hierarchical control proposed consists of three levels: 1) The primary control is based on the droop method, including an output-impedance virtual loop; 2) the secondary control allows the restoration of the deviations produced by the primary control; and 3) the tertiary control manages the power flow between the MG and the external electrical distribution system. Results from a hierarchical-controlled MG are provided to show the feasibility of the proposed approach.
1 August 2005 in IEEE Transactions on Industrial Electronics
This paper deals with the design of the output impedance of uninterruptible power system (UPS) inverters with parallel-connection capability. In order to avoid the need for any communication among modules, the power-sharing control loops are based on the P/Q droop method. Since in these systems the power-sharing accuracy is highly sensitive to the inverters output impedance, novel control loops to achieve both stable output impedance and proper power balance are proposed. In this sense, a novel wireless controller is designed by using three nested loops: 1) the inner loop is performed by using feedback linearization control techniques, providing a good quality output voltage waveform; 2) the intermediate loop enforces the output impedance of the inverter, achieving good harmonic power sharing while maintaining low output voltage total harmonic distortion; and 3) the outer loop calculates the output active and reactive powers and adjusts the output impedance value and the output voltage frequency during the load transients, obtaining excellent power sharing without deviations in either the frequency or the amplitude of the output voltage. Simulation and experimental results are reported from a parallel-connected UPS system sharing linear and nonlinear loads.
3 September 2004 in IEEE Transactions on Power Electronics
This paper presents a novel control strategy for parallel inverters of distributed generation units in an AC distribution system. The proposed control technique, based on the droop control method, uses only locally measurable feedback signals. This method is usually applied to achieve good active and reactive power sharing when communication between the inverters is difficult due to its physical location. However, the conventional voltage and frequency droop methods of achieving load sharing have a slow and oscillating transient response. Moreover, there is no possibility to modify the transient response without the loss of power sharing precision or output-voltage and frequency accuracy. In this work, a great improvement in transient response is achieved by introducing power derivative-integral terms into a conventional droop scheme. Hence, better controllability of the system is obtained and, consequently, correct transient performance can be achieved. In addition, an instantaneous current control loop is also included in the novel controller to ensure correct sharing of harmonic components when supplying nonlinear loads. Simulation and experimental results are presented to prove the validity of this approach, which shows excellent performance as opposed to the conventional one.
22 March 2010 in IEEE Transactions on Industrial Electronics
This paper investigates the characteristics of the active and reactive power sharing in a parallel inverters system under different system impedance conditions. The analyses conclude that the conventional droop method cannot achieve efficient power sharing for the case of a system with complex impedance condition. To achieve the proper power balance and minimize the circulating current in the different impedance situations, a novel droop controller that considers the impact of complex impedance is proposed in this paper. This controller can simplify the coupled active and reactive power relationships, which are caused by the complex impedance in the parallel system. In addition, a virtual complex impedance loop is included in the proposed controller to minimize the fundamental and harmonic circulating current that flows in the parallel system. Compared to the other methods, the proposed controller can achieve accurate power sharing, offers efficient dynamic performance, and is more adaptive to different line impedance situations. Simulation and experimental results are presented to prove the validity and the improvements achieved by the proposed controller.
18 November 2008 in IEEE Transactions on Industrial Electronics
In this paper, the control strategy for a flexible microgrid is presented. The microgrid presented here consists of several line-interactive uninterruptible power supply (UPS) systems connected in parallel. The control technique is based on the droop method to avoid critical communications among UPS units. Thus, a flexible microgrid is obtained to operate in either grid-connected or islanded mode. A small-signal analysis is presented in order to analyze the system stability, which gives rules to design the main control parameters. Simulation and experimental results are presented, showing the feasibility of the proposed controller.
2 October 2006 in IEEE Transactions on Industrial Electronics
In this paper, a method for the parallel operation of inverters in an ac-distributed system is proposed. This paper explores the control of active and reactive power flow through the analysis of the output impedance of the inverters and its impact on the power sharing. As a result, adaptive virtual output impedance is proposed in order to achieve a proper reactive power sharing, regardless of the line-impedance unbalances. A soft-start operation is also included, avoiding the initial current peak, which results in a seamless hot-swap operation. Active power sharing is achieved by adjusting the frequency in load transient situations only, owing to which the proposed method obtains a constant steady-state frequency and amplitude. As opposed to the conventional droop method, the transient response can be modified by acting on the main control parameters. Linear and nonlinear loads can be properly shared due to the addition of a current harmonic loop in the control strategy. Experimental results are presented from a two-6-kVA parallel-connected inverter system, showing the feasibility of the proposed approach