Xinghai Chen

Dr. Xinghai Chen

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Food and Chemical Toxicology
Verified
Journal Article
Closed access
YMYa Ma
Ya Ma
HLHaohao Liu
Haohao Liu
XDXingde Du
Xingde Du
PPPavankumar Petlulu
Pavankumar Petlulu
XCXinghai Chen
Xinghai Chen
HZHuizhen Zhang
Huizhen Zhang

29 January 2021 in Fetal and Pediatric Pathology
Verified
Journal Article
Closed access
XLXuelai Liu
Xuelai Liu
YSYanbiao Song
Yanbiao Song
PHPeiyu Hao
Peiyu Hao
XCXinghai Chen
Xinghai Chen
JZJun Zhang
Jun Zhang
ZJZhe-Wu Jin
Zhe-Wu Jin
We compared the cross-sectional areas of the duodenum to the distal small intestine during early gestation to determine if there is a difference in age for recanalization. Serial sagittal sections ...

11 January 2024 in Geophysics
Verified
Journal Article
Closed access
TXTong Xia
Tong Xia
MYMingxin Yue
Mingxin Yue
XYXiaodong Yang
Xiaodong Yang
XCXinghai Chen
Xinghai Chen
HNHuihui Niu
Huihui Niu
XWXiaoping Wu
Xiaoping Wu
Small-loop transient electromagnetic (TEM) devices, several meters in size, are increasingly applied to near-surface geophysical exploration in space-limited environments. But the transmitter (TX) coil significantly affects the early time data acquisition of the receiver (RX) coil during current turn-off, resulting in the loss of shallow signals and creating a significant blind zone problem. We report a double-coil decoupling TEM (DCDTEM) device to solve this problem. The novel DCDTEM device ensures a weak primary magnetic flux region between the two coplanar TX coils with the same current direction and different radii. Simulation results indicate that the transmitting field of the DCDTEM device is more focused than the traditional central loop device, ensuring a stronger coupling with the target. The 3D TEM forward-modeling results show that the DCDTEM device has the highest detection sensitivity, together with a relatively high lateral resolution compared with other small-loop TEM devices. We further carry out several physical experiments to test the response characteristics of the DCDTEM device with reference to the offset and the ratio of turns between the TX and RX coils. The experimental results ensure that the position of the zero magnetic flux point can be accurately calibrated and mitigate interference from TX coils. Our DCDTEM device is also applied in a field test on water pipe detection, demonstrating its practicality in near-surface detection.

31 October 2025 in Near Surface Geophysics
Verified
Journal Article
Closed access
XCXinghai Chen
Xinghai Chen
LTLei Tan
Lei Tan
XYXiaodong Yang
Xiaodong Yang
XWXiaoping Wu
Xiaoping Wu
GZGuanqun Zhou
Guanqun Zhou
QZQingle Zhang
Qingle Zhang

13 January 2025 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XCXinghai Chen
Xinghai Chen
Haiyan YangHaiyan Yang
Haiyan Yang
TXTong Xia
Tong Xia
XWXiaoping Wu
Xiaoping Wu
SLShengdong Liu
Shengdong Liu
The small-loop transient electromagnetic method (TEM) refers to a system in which the coil frame length or diameter is less than 2 m. Due to the inductive effects of the multi-turn coils used for both transmission and reception, the induced electromotive force in the measuring coil increases, causing a reduction in the decay rate and an extension of the shutoff time. This results in coupling between the primary and secondary fields in early-time signals, making them difficult to separate and creating a detection blind spot in the shallow subsurface. The opposing coil TEM transmission and reception method can significantly reduce early-time signal distortion caused by coil inductance. However, this approach is constrained by the physical symmetry of the coil dimensions, which makes it challenging to achieve balance in a zero-field space. By performing both forward and reverse measurements at the same location using the opposing coil setup and calculating the difference between the signals, the inductive coupling between coils at the measurement site can theoretically be eliminated. This eliminates the induced potential of the TEM signal, enhancing the induced electromotive force from the formation. As a result, more accurate resistivity values are obtained, detection blind spots are eliminated, and the resolution in shallow TEM exploration is improved. Field experiments were conducted to validate the method on both high-resistivity and low-resistivity anomalies. The results demonstrated that this method effectively identified a high-resistivity corrugated pipe at a depth of 1.2 m and two low-resistivity gas pipelines at a depth of 2 m, thereby essentially eliminating detection blind spots in the shallow subsurface.

20 September 2024 in Acta Geophysica
Verified
Journal Article
Closed access
PDF file
XCXinghai Chen
Xinghai Chen
XYXiaoDong Yang
XiaoDong Yang
XCXinghai Chen
Xinghai Chen
YCYu Cao
Yu Cao
MYMingXin Yue
MingXin Yue
GZGuanqun Zhou
Guanqun Zhou