Lunming Qin

Dr. Lunming Qin


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2022 in Frontiers in Energy Research
Verified
Journal Article
Open access
LSLei Su
Lei Su
HHHua Huang
Hua Huang
LQLunming Qin
Lunming Qin
WZWenbin Zhao
Wenbin Zhao
In recent years, large-scale renewable energy access to substations has brought overload, harmonic, short circuit and other problems, which has led to an increase in the failure rate and shortening the service life of important power equipment such as transformers. Transformer is one of the key equipment in power system, and its operation status has an important impact on the safe and stable operation of power grid. In order to realize the real-time state evaluation of transformer, a real-time vibration signal detection method based on video is proposed in this paper. Firstly, YOLOv4 is used to detect the transformer object, and then the pyramid Lucas-Kanade optical flow method and Otsu method are used to calculate the transformer vibration vector. Experimental results show that the transformer vibration vector can be calculated in real time and accurately by using the proposed algorithm, so as to realize the real-time reliable analysis of the transformer state.

22 April 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
CZCunkai Zhou
Cunkai Zhou
YTYe Tian
Ye Tian
GLGen Li
Gen Li
YYYifei Ye
Yifei Ye
LGLusha Gao
Lusha Gao
Liuyang SunLiuyang Sun
Liuyang Sun
In implantable electrophysiological recording systems, the headstage typically comprises neural probes that interface with brain tissue and integrated circuit chips for signal processing. While advancements in MEMS and CMOS technology have significantly improved these components, their interconnection still relies on conventional printed circuit boards and sophisticated adapters. This conventional approach adds considerable weight and volume to the package, especially for high channel count systems. To address this issue, we developed a through-polymer via (TPV) method inspired by the through-silicon via (TSV) technique in advanced three-dimensional packaging. This innovation enables the vertical integration of flexible probes, amplifier chips, and PCBs, realizing a flexible, lightweight, and integrated device (FLID). The total weight of the FLIDis only 25% that of its conventional counterparts relying on adapters, which significantly increased the activity levels of animals wearing the FLIDs to nearly match the levels of control animals without implants. Furthermore, by incorporating a platinum-iridium alloy as the top layer material for electrical contact, the FLID realizes exceptional electrical performance, enabling in vivo measurements of both local field potentials and individual neuron action potentials. These findings showcase the potential of FLIDs in scaling up implantable neural recording systems and mark a significant advancement in the field of neurotechnology.

22 October 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
WJWei Ji
Wei Ji
HSHaoyang Su
Haoyang Su
SJShuang Jin
Shuang Jin
YTYe Tian
Ye Tian
GLGen Li
Gen Li
Liuyang SunLiuyang Sun
Liuyang Sun
Wireless neural signal transmission is essential for both neuroscience research and neural disorder therapies. However, conventional wireless systems are often constrained by low sampling rates, limited channel counts, and their support of only a single transmission mode. Here, we developed a wireless bi-directional brain–computer interface system featuring dual transmission modes. This system supports both low-power Bluetooth transmission and high-sampling-rate Wi-Fi transmission, providing flexibility for various application scenarios. The Bluetooth mode, with a maximum sampling rate of 14.4 kS/s, is well suited for detecting low-frequency signals, as demonstrated by both in vitro recordings of signals from 10 to 50 Hz and in vivo recordings of 16-channel local field potentials in mice. More importantly, the Wi-Fi mode, offering a maximum sampling rate of 56.8 kS/s, is optimized for recording high-frequency signals. This capability was validated through in vitro recordings of signals from 500 to 2000 Hz and in vivo recordings of single-neuron spike firings with amplitudes reaching hundreds of microvolts and high signal-to-noise ratios. Additionally, the system incorporates a wireless stimulation function capable of delivering current pulses up to 2.55 mA, with adjustable pulse width and polarity. Overall, this dual-mode system provides an efficient and flexible solution for both neural recording and stimulation applications.

12 December 2025 in The Visual Computer
Verified
Journal Article
Closed access
PDF file
HBHouqin Bian
Houqin Bian
QCQifei Chen
Qifei Chen
HZHaolin Zhang
Haolin Zhang
LQLunming Qin
Lunming Qin
HCHaoyang Cui
Haoyang Cui
XWXi Wang
Xi Wang

18 April 2024 in Signal, Image and Video Processing
Verified
Journal Article
Closed access
PDF file
HBHouqin Bian
Houqin Bian
SFShihe Fan
Shihe Fan
HZHaolin Zhang
Haolin Zhang
LQLunming Qin
Lunming Qin
HCHaoyang Cui
Haoyang Cui
XWXi Wang
Xi Wang

5 June 2025 in Multimedia Systems
Verified
Journal Article
Closed access
PDF file
HBHouqin Bian
Houqin Bian
QCQifei Chen
Qifei Chen
HZHaolin Zhang
Haolin Zhang
LQLunming Qin
Lunming Qin
LXLiang Xue
Liang Xue
XWXi Wang
Xi Wang