Shenhui Chen

Mr. Shenhui Chen

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2024 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
TWTao Wang
Tao Wang
JZJihui Zhang
Jihui Zhang
XLXin Li
Xin Li
SCShenhui Chen
Shenhui Chen
京马京浩 马
京浩 马
HHHonglin Han
Honglin Han
In response to the challenges posed by large-scale, uncoordinated electric vehicle charging on the power grid, Vehicle-to-Grid (V2G) technology has been developed. This technology seeks to synchronize electric vehicles with the power grid, improving the stability of their connections and fostering positive energy exchanges between them. The key component for implementing V2G technology is the bidirectional AC/DC converter. This study concentrates on the non-isolated bidirectional AC/DC converter, providing a detailed analysis of its two-stage operation and creating a mathematical model. A dual closed-loop control structure for voltage and current is designed based on nonlinear control theory, along with a constant current charge–discharge control strategy. Furthermore, midpoint potential balance is achieved through zero-sequence voltage injection control, and power signals for the switching devices are generated using Space Vector Pulse Width Modulation (SVPWM) technology. A simulation model of the V2G system is then constructed in MATLAB/Simulink for analysis and validation. The findings demonstrate that the control strategy proposed in this paper improves the system’s robustness, dynamic performance, and resistance to interference, thus reducing the effects of large-scale, uncoordinated electric vehicle charging on the power grid.

22 November 2024 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
TWTao Wang
Tao Wang
SCShenhui Chen
Shenhui Chen
XLXin Li
Xin Li
JZJihui Zhang
Jihui Zhang
京马京浩 马
京浩 马
Taking a Vienna rectifier as the research object, the power mathematical model based on a switching function is established according to its working principle. A sliding mode variable structure control algorithm based on the reaching law is examined in order to address the issues of the slow response speed and inadequate anti-interference of classical PI control in the face of abrupt changes in the DC-side load. In response to the sluggish convergence rate and inadequate chattering suppression of classical integer order sliding mode control, a fractional order exponential reaching law sliding mode, direct power control approach with rapid convergence is developed. The fractional calculus is introduced into the sliding mode control, and the dynamic performance and convergence speed of the control system are improved by increasing the degree of freedom of the fractional calculus operator. The method of including a balance factor in the zero-sequence component is employed to address the issue of the midpoint potential equilibrium in the Vienna rectifier. Ultimately, the suggested control is evaluated against classical PI control through simulation analysis and experimental validation. The findings indicate that the proposed technique exhibits rapid convergence, reduced control duration, and enhanced robustness, hence augmenting its resistance to interference.

Verified
Journal Article
Open access
PDF file
TWTao Wang
Tao Wang
XLXin Li
Xin Li
JZJihui Zhang
Jihui Zhang
SCShenhui Chen
Shenhui Chen
京马京浩 马
京浩 马
CLCunhao Lin
Cunhao Lin
This research presents a novel current loop control strategy for a three-phase PWM rectifier system aimed at mitigating challenges related to substandard power quality, excessive current harmonics, and insufficient robustness. The suggested approach combines an extended state observer (ESO) with dual-power sliding mode control that is further enhanced by fractional-order micro-integral operators. This amalgamation enhances the adaptability of the controller to system dynamics and augments the flexibility of the current loop control mechanism. The results of this integration include diminished system oscillations, heightened immunity to external disturbances, and improved robustness and dynamics of the overall system. Through MATLAB/Simulink simulations, the effectiveness of the proposed control methodology is validated, demonstrating superior performance in terms of robustness, dynamic response, power quality enhancement, and mitigation of current harmonics when compared to conventional PI control and standard fractional-order dual-power sliding mode control techniques.

17 November 2024 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
TWTao Wang
Tao Wang
京马京浩 马
京浩 马
CLCunhao Lin
Cunhao Lin
XLXin Li
Xin Li
SCShenhui Chen
Shenhui Chen
JZJihui Zhang
Jihui Zhang
To facilitate seamless transitions between grid-connected and islanded modes in PV–storage–charging integration, an energy storage system converter is designated as the subject of investigation, and its operational principles are examined. Feed-forward decoupling, double closed-loop, constant-power (PQ), constant-voltage–constant-frequency (V/F), and constant-voltage charge and discharge control strategies are developed. The PQ and V/F control framework of the energy storage battery comprises an enhanced common current inner loop and a switching voltage outer loop. The current reference value output by the voltage outer loop and the voltage signal output by the current inner loop are compensated. The transient impact is reduced, and the smooth switching of the microgrid from the grid-connected mode to the island mode is realized, which significantly improves the power quality and ensures the uninterrupted charging of electric vehicles and the stable operation of the key load of the system. By constructing a simulation model of the photovoltaic energy storage microgrid on the MATLAB/Simulink platform, the practicability of the control strategy proposed in this paper is verified.