Evgenii Nikitin

Mr. Evgenii Nikitin

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
YVYuriy Vasilev
Yuriy Vasilev
DRDenis Andreevich Rumyantsev
Denis Andreevich Rumyantsev
AVAnton Vladzymyrskyy
Anton Vladzymyrskyy
OOOlga Omelyanskaya
Olga Omelyanskaya
LPLev Pestrenin
Lev Pestrenin
KAKirill Arzamasov
Kirill Arzamasov
Background: The implementation of radiological artificial intelligence (AI) solutions remains challenging due to limitations in existing testing methodologies. This study assesses the efficacy of a comprehensive methodology for performance testing and monitoring of commercial-grade mammographic AI models. Methods: We utilized a combination of retrospective and prospective multicenter approaches to evaluate a neural network based on the Faster R-CNN architecture with a ResNet-50 backbone, trained on a dataset of 3641 mammograms. The methodology encompassed functional and calibration testing, coupled with routine technical and clinical monitoring. Feedback from testers and radiologists was relayed to the developers, who made updates to the AI model. The test dataset comprised 112 medical organizations, representing 10 manufacturers of mammography equipment and encompassing 593,365 studies. The evaluation metrics included the area under the curve (AUC), accuracy, sensitivity, specificity, technical defects, and clinical assessment scores. Results: The results demonstrated significant enhancement in the AI model’s performance through collaborative efforts among developers, testers, and radiologists. Notable improvements included functionality, diagnostic accuracy, and technical stability. Specifically, the AUC rose by 24.7% (from 0.73 to 0.91), the accuracy improved by 15.6% (from 0.77 to 0.89), sensitivity grew by 37.1% (from 0.62 to 0.85), and specificity increased by 10.7% (from 0.84 to 0.93). The average proportion of technical defects declined from 9.0% to 1.0%, while the clinical assessment score improved from 63.4 to 72.0. Following 2 years and 9 months of testing, the AI solution was integrated into the compulsory health insurance system. Conclusions: The multi-stage, lifecycle-based testing methodology demonstrated substantial potential in software enhancement and integration into clinical practice. Key elements of this methodology include robust functional and diagnostic requirements, continuous testing and updates, systematic feedback collection from testers and radiologists, and prospective monitoring.

26 June 2023 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
ENEvgenii Nikitin
Evgenii Nikitin
НДНикитин Евгений Дмитриевич
Никитин Евгений Дмитриевич
BACKGROUND: One of the common problems in labeling medical images is inter-observer variability. The same image can be labeled differently by doctors. The main reasons are the human factor, differences in experience and qualifications, different radiology schools, poor image quality, and unclear instructions. The influence of some factors can be reduced by proper organization of the annotation; however, the opinion of doctors frequently differs. AIM: The study aimed to test whether a neural network with an additional module can learn the style and labeling features of different radiologists and whether such modeling can improve the final metrics of object detection on radiological images. METHODS: For training artificial intelligence systems in radiology, cross-labeling, i.e., annotation of the same image by several doctors, is frequently used. The easiest way is to use labeling from each doctor as an independent example when training the model. Some methods use different rules or algorithms to combine annotation before training. Finally, Guan et al. use separate classification heads to model the labeling style of different doctors. Unfortunately, this method is not suitable for more complex tasks, such as detecting objects on an image. For this analysis, a machine learning model designed to detect objects of different classes on mammographic scans was used. This model is a neural network based on Deformable DETR architecture. A dataset consisting of 7,756 mammographic breast scans and 12,543 unique annotations from 19 doctors was used to train the neural network. For validation and testing, a dataset consisting of 700 and 300 Bi-Rads-labeled scans, respectively, was taken. In all data sets, the proportion of images with pathology was in the 15%20% range. A unique index was assigned to each of the 19 doctors, and a special module at each iteration of the neural network training found a vector corresponding to this index. The vector was expanded to the size of the feature map of each level of the feature pyramid, and then attached by separate channels to the maps. Thus, the encoder and the decoder of the detector had access to the information about which doctor labeled the scan. The vectors were updated using the back-propagation method. Three methods were chosen for comparison: Basic model: Combining labels by different doctors using the voting method. New stylistic module: For predictions on the test dataset, a single doctors index was taken, which showed the best metrics on the validation dataset. New stylistic module: The indexes of the five doctors with the best metrics on the validation dataset were used for predictions on the test dataset. Weighted Boxes Fusion was chosen to combine the predictions. The area under the receiver operating characteristic curve (ROC-AUC) was used as the primary metric on the test dataset (Bi-Rads 3, 4, and 5 categories were referred to pathology). The sum of maximum probabilities of detected malignant objects (malignant masses and calcinates) by cranio-caudal and medio-lateral oblique projections was assumed as the probability of malignancy for each method. RESULTS: The following ROC-AUC metrics were obtained for the three methods: 0.82, 0.87, and 0.89. CONCLUSIONS: The information about the labeling doctor allows the neural network to learn and model the labeling style of different doctors more effectively. In addition, this method may obtain an estimate of the uncertainty of the networks prediction. The use of embedding from different doctors, leading to different predictions, may mean that this data is difficult for an artificial intelligence system to process.

21 March 2022 in Koloproktologia
Verified
Journal Article
Open access
PDF file
RER. R. Eligulashvili
R. R. Eligulashvili
IZI. V. Zarodnyuk
I. V. Zarodnyuk
SASergey I. Achkasov
Sergey I. Achkasov
DBD. M. Belov
D. M. Belov
VMV. A. Mikhalchenko
V. A. Mikhalchenko
NFN. S. Filatov
N. S. Filatov
Применение искусственного интеллекта в МРТ диагностике рака прямой кишки

2 July 2024 in Digital Diagnostics
Verified
Journal Article
Open access
PDF file
ENEvgenii Nikitin
Evgenii Nikitin
NPNikita S. Plaksin
Nikita S. Plaksin
MGMaria B. Garetz
Maria B. Garetz
EGEvgeniy M. Gutin
Evgeniy M. Gutin
ГБГарец Мария Борисовна
Гарец Мария Борисовна
BACKGROUND: Up to 95% of digital fluoroscopy screening studies are free of pathologic changes. Radiologists typically spend the majority of their time reviewing and describing such studies. In these cases, artificial intelligence systems can be used to automate the description, thereby saving physicians’ time [1–3]. AIM: The aim of this study was to compare the efficacy of various algorithms within an existing artificial intelligence system in an ultra-high sensitivity scenario and to estimate the percentage of X-rays that could be automatically characterized. MATERIALS AND METHODS: The artificial intelligence system “Cels.Fluorography” version 0.15.3 was used for the analysis. A dataset derived from disparate medical organizations, comprising 11,707 studies devoid of pathology and 5,846 studies exhibiting pathology, was selected for comparison. A subsample of 500 studies with pathology and 9,500 studies without pathology (5% to 95% balance) was randomly selected 1,000 times from the dataset to calculate the metrics. The resulting metrics were then averaged. The markup of two physicians was used as the source of the target variable. In the event of a discrepancy in opinion, the study was subjected to an expert physician evaluation. An X-ray was considered pathological if the final markup contained at least one of 12 radiological features [4]. Five methods were used to compare metrics: by maximum (1) and mean (2) probability of radiological features localized by the neural network-detector; by maximum (3) and mean (4) probability of feature presence derived from dedicated “heads” of the neural network trained to determine the presence of each feature on the image (0 for no feature, 1 for presence); by probability (5) derived from a separate “head” of the neural network trained to determine the binary presence of pathology on the study (0 for normal, 1 for pathology). For each method, a response threshold was selected to ensure that no more than one missed pathology was identified per 1,000 examinations in the current subsample. The percentage of X-rays that could be correctly identified as pathology-free by artificial intelligence was calculated as the main quality metric. RESULTS: The methods demonstrated the following average percentages of norm dropout: 66.4%, 72.2%, 69.0%, 74.1%, 68.7%—and the following area under the ROC curve: 0.948, 0.957, 0.964, 0.967, 0.971. The 95% confidence interval for the dropout rate associated with the optimal method was found to be 66.1% to 79.4%. CONCLUSIONS: Modern artificial intelligence systems can be used to automate the description of a significant portion of screenings. The most efficacious method for norm screening (over 74% of the flow) was demonstrated by the averaging of probabilities derived from special “heads” of the neural network trained to identify the presence of pathology.

21 March 2022 in Koloproktologia
Verified
Journal Article
Open access
PDF file
RER. R. Eligulashvili
R. R. Eligulashvili
IZI. V. Zarodnyuk
I. V. Zarodnyuk
SASergey I. Achkasov
Sergey I. Achkasov
DBD. M. Belov
D. M. Belov
VMV. A. Mikhalchenko
V. A. Mikhalchenko
NFN. S. Filatov
N. S. Filatov
Применение искусственного интеллекта в МРТ диагностике рака прямой кишки