Martin G. Jørgensen

Dr. Martin G. Jørgensen


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Clinical Nutrition
Verified
Journal Article
Closed access
RTRandi Tobberup
Randi Tobberup
ACAndreas Carus
Andreas Carus
HRHenrik H. Rasmussen
Henrik H. Rasmussen
UFUrsula Gerda Falkmer
Ursula Gerda Falkmer
MJMartin G. Jørgensen
Martin G. Jørgensen
MHMette Holst
Mette Holst

3 February 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
ABA. W. Blomkvist
A. W. Blomkvist
SAStig Andersen
Stig Andersen
EBEling D. de Bruin
Eling D. de Bruin
MJMartin G. Jørgensen
Martin G. Jørgensen
Low hand grip strength is a strong predictor for both long-term and short-term disability and mortality. The Nintendo Wii Balance Board (WBB) is an inexpensive, portable, wide-spread instrument with the potential for multiple purposes in assessing clinically relevant measures including muscle strength. The purpose of the study was to explore intrarater reliability and concurrent validity of the WBB by comparing it to the Jamar hand dynamometer. Intra-rater test-retest cohort design with randomized validity testing on the first session. Using custom WBB software, thirty old adults (69.0 ± 4.2 years of age) were studied for reproducibility and concurrent validity compared to the Jamar hand dynamometer. Reproducibility was tested for dominant and non-dominant hands during the same time-of-day, one week apart. Intraclass correlation coefficient (ICC) and standard error of measurement (SEM) and limits of agreement (LOA) were calculated to describe relative and absolute reproducibility respectively. To describe concurrent validity, Pearson’s product–moment correlation and ICC was calculated. Reproducibility was high with ICC values of >0.948 across all measures. Both SEM and LOA were low (0.2-0.5 kg and 2.7-4.2 kg, respectively) in both the dominant and non-dominant hand. For validity, Pearson correlations were high (0.80-0.88) and ICC values were fair to good (0.763-0.803). Reproducibility for WBB was high for relative measures and acceptable for absolute measures. In addition, concurrent validity between the Jamar hand dynamometer and the WBB was acceptable. Thus, the WBB may be a valid instrument to assess hand grip strength in older adults.

1 April 2014 in Gait & Posture
Verified
Journal Article
Closed access
RSRasmus Reinholdt Sørensen
Rasmus Reinholdt Sørensen
MJMartin G. Jørgensen
Martin G. Jørgensen
Sten RasmussenSten Rasmussen
Sten Rasmussen
SSSøren T Skou
Søren T Skou

7 October 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MJMartin G. Jørgensen
Martin G. Jørgensen
SAStig Andersen
Stig Andersen
JRJesper Ryg
Jesper Ryg
TMTahir Masud
Tahir Masud
Portable, low-cost, objective and reproducible assessment of muscle strength in the lower limbs is important as it allows clinicians to precisly track progression of patients undergoing rehabilitation. The Nintendo Wii Balance Board (WBB) is portable, inexpensive, durable, available worldwide, and may serve the above function. The purpose of the study was to evaluate (1) reproducibility and (2) concurrent validity of the WBB for measuring isometric muscle strength in the lower limb. A custom hardware and software was developed to utilize the WBB for assessment of isometric muscle strength. Thirty older adults (69.0±4.2 years of age) were studied on two separate occasions on both the WBB and a stationary isometric dynamometer (SID). On each occasion, three recordings were obtained from each device. For the first recording, means and maximum values were used for further analysis. The test-retest reproducibility was examined using intraclass correlation coefficients (ICC), Standard Error of Measurement (SEM), and limits of agreement (LOA). Bland-Altman plots (BAP) and ICC’s were used to explore concurrent validity. No systematic difference between test-retest was detected for the WBB. ICC within-device were between 0.90 and 0.96 and between-devices were from 0.80 to 0.84. SEM ranged for the WBB from 9.7 to 13.9%, and for the SID from 11.9 to 13.1%. LOA ranged for the WBB from 20.3 to 28.7% and for the SID from 24.2 to 26.6%. The BAP showed no relationship between the difference and the mean. A high relative and an acceptable absolute reproducibility combined with a good validity was found for the novel method using the WBB for measuring isometric lower limb strength in older adults. Further research using the WBB for assessing lower limb strength should be conducted in different study-populations.

15 August 2020 in Journal of the American Geriatrics Society
Verified
Journal Article
Closed access
PDF file
MDMathias Brix Danielsen
Mathias Brix Danielsen
SAStig Andersen
Stig Andersen
EWElisa Worthington
Elisa Worthington
MJMartin G. Jørgensen
Martin G. Jørgensen

30 June 2021 in BMC Geriatrics
Verified
Journal Article
Open access
PDF file
GGGustav Valentin Gade
Gustav Valentin Gade
MJMartin G. Jørgensen
Martin G. Jørgensen
JRJesper Ryg
Jesper Ryg
TMTahir Masud
Tahir Masud
LJLasse Hjort Jakobsen
Lasse Hjort Jakobsen
SAStig Andersen
Stig Andersen
Background: Falls are the leading cause of fatal and non-fatal injuries in older adults, and attention to falls prevention is imperative. Prognostic models identifying high-risk individuals could guide fall-preventive interventions in the rapidly growing older population. We aimed to develop a prognostic prediction model on falls rate in community-dwelling older adults. Methods: Design: prospective cohort study with 12 months follow-up and participants recruited from June 14, 2018, to July 18, 2019. Setting: general population. Subjects: community-dwelling older adults aged 75+ years, without dementia or acute illness, and able to stand unsupported for one minute. Outcome: fall rate for 12 months. Statistical methods: candidate predictors were physical and cognitive tests along with self-report questionnaires. We developed a Poisson model using least absolute shrinkage and selection operator penalization, leave-one-out cross-validation, and bootstrap resampling with 1000 iterations. Results: Sample size at study start and end was 241 and 198 (82%), respectively. The number of fallers was 87 (36%), and the fall rate was 0.94 falls per person-year. Predictors included in the final model were educational level, dizziness, alcohol consumption, prior falls, self-perceived falls risk, disability, and depressive symptoms. Mean absolute error (95% CI) was 0.88 falls (0.71–1.16). Conclusion: We developed a falls prediction model for community-dwelling older adults in a general population setting. The model was developed by selecting predictors from among physical and cognitive tests along with self-report questionnaires. The final model included only the questionnaire-based predictors, and its predictions had an average imprecision of less than one fall, thereby making it appropriate for clinical practice. Future external validation is needed. Trial registration: Clinicaltrials.gov (NCT03608709).