As the proportion of renewable energy in power system continues to increase, that power system will face the risk of a multi-time-scale supply and demand imbalance. The rational planning of energy storage facilities can achieve a dynamic time–delay balance between power system supply and demand. Based on this, and in order to realize the location and capacity optimization determination of multiple types of energy storage in power system, this paper proposes a collaborative optimization planning framework for multiple types of energy storage. The proposed planning framework is modelled as a two-stage MILP model based on scenarios via the stochastic optimization method. In the first stage, investment decisions are made for two types of energy storage: battery energy storage (short term) and hydrogen energy storage (long term). In the second stage, power system operation simulation is conducted based on typical scenarios. Finally, the progressive hedging (PH) algorithm is applied to realize the efficient solving of the proposed model. A modified IEEE 39-bus test system is used to verify the validity of the proposed multiple types of energy storage collaborative optimization planning model and PH algorithm.
This paper focuses on the evaluation of the operational effect of a pumped storage plant in a new power system. An evaluation index system is established by selecting key indicators from the four benefit dimensions of system economy, low carbon, flexibility, and reliability. The evaluation criteria are based on the values of indexes for pumped storage plants that have already been put into operation. Using this method, the operational effect of pumped storage plants with different installed capacities, regulation durations, and conversion efficiencies are comprehensively evaluated and analyzed. The calculation results show that the operation effect of a pumped storage plant with high regulation performance and high comprehensive conversion efficiency is better, indicating that the established index system and evaluation method can comprehensively and truly reflect the positive benefits brought by a pumped storage plant to a new power system. This study can provide a practical reference for the early planning and decision making of pumped storage in a new power system.
As the adoption of renewable energy sources grows, ensuring a stable power balance across various time frames has become a central challenge for modern power systems. In line with the “dual carbon” objectives and the seamless integration of renewable energy sources, harnessing the advantages of various energy storage resources and coordinating the operation of long-term and short-term storage have become pivotal directions for future energy storage deployment. To address the complexities arising from the coupling of different time scales in optimizing energy storage capacity, this paper proposes a method for energy storage planning that accounts for power imbalance risks across multiple time scales. Initially, the Seasonal and Trend decomposition using the Loess (STL) decomposition method is utilized to temporally decouple actual operational data. Subsequently, power balance computations are performed based on the obtained data at various time scales to optimize the allocation of different types of energy storage capacities and assess the associated imbalance risks. Finally, the effectiveness of the proposed approach is validated through hourly applications using real-world data from a province in southern China over recent years.
With the rise in the proportion of renewable energy and energy storage in modern power systems, the volatility of renewable energy and the increasing demand for loads pose a significant risk of congestion in transmission lines. Along with transmission congestion, prolonged heavy loads on transmission lines increase equipment failure rates, leading to a range of issues within the power system. This study proposes a scene clustering method for power system scheduling by leveraging the net load related with the load and renewable energy power outputs. Subsequently, a scheduling model and line load evaluation indexes were developed to analyze the line load rate of power systems with different renewable energy proportions. The simulation results indicate that the utilization rate of lines, the fluctuation rate of line load, the maximum line load, and heavy line load time increase as the installed proportion of renewable energy increases. Finally, a penalty term for heavy loads was incorporated into the objective function and methods of rescheduling and planning energy storage considering the heavy load penalty function are proposed. A case study validated the significant improvements in load management, achieving a reduction in heavy load time by approximately 30% and reducing transmission congestion by 20% under high-renewable-energy-penetration scenarios. These results illustrate the effectiveness of the heavy load cost function in enhancing system resilience and optimizing load distribution.
With the increasing integration of stochastic sources and loads, ensuring the flexibility of AC/DC hybrid distribution networks has become a pressing challenge. This paper aims to enhance the operational flexibility of AC/DC hybrid distribution networks by proposing a flexibility-oriented optimization framework that addresses the growing uncertainties. Notably, a comprehensive evaluation method for operational flexibility assessment is first established. Based on this, this paper further proposes a flexibility-oriented operation optimization model using the distributionally robust chance-constrained (DRCC) method. A customized solution method utilizing second-order cone relaxation and sample average approximation (SAA) is also introduced. The results of case studies indicate that the flexibility of AC/DC hybrid distribution networks is enhanced through sharing energy storage among multiple feeders, adaptive reactive power regulation using soft open points (SOPs) and static var compensators (SVCs), and power transfer between feeders via SOPs.
As the adoption of renewable energy sources grows, ensuring a stable power balance across various time frames has become a central challenge for modern power systems. In line with the "dual carbon" objectives and the seamless integration of renewable energy sources, harnessing the advantages of various energy storage resources and coordinating the operation of long-term and short-term storage have become pivotal directions for future energy storage deployment. To address the complexities arising from the coupling of different time scales in optimizing energy storage capacity, this paper proposes a method for energy storage planning that accounts for power imbalance risks across multiple time scales. Initially, the Seasonal and Trend decomposition using the Loess (STL) decomposition method is utilized to temporally decouple actual operational data. Subsequently, power balance computations are performed based on the obtained data at various time scales to optimize the allocation of different types of energy storage capacities and assess the associated imbalance risks. Finally, the effectiveness of the proposed approach is validated through hourly applications using real-world data from a province in China over recent years.