Martina Cotena

Dr. Martina Cotena

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MCMartina Cotena
Martina Cotena
Angela AyobiAngela Ayobi
Angela Ayobi
CZColin Zuchowski
Colin Zuchowski
JJJacqueline C. Junn
Jacqueline C. Junn
Brent WeinbergBrent Weinberg
Brent Weinberg
SQsarah Quenet
sarah Quenet
Background and Objectives: Acute aortic dissection (AD) is a life-threatening condition in which early detection can significantly improve patient outcomes and survival. This study evaluates the clinical benefits of integrating a deep learning (DL)-based application for the automated detection and prioritization of AD on chest CT angiographies (CTAs) with a focus on the reduction in the scan-to-assessment time (STAT) and interpretation time (IT). Materials and Methods: This retrospective Multi-Reader Multi-Case (MRMC) study compared AD detection with and without artificial intelligence (AI) assistance. The ground truth was established by two U.S. board-certified radiologists, while three additional expert radiologists served as readers. Each reader assessed the same CTAs in two phases: assessment unaided by AI assistance (pre-AI arm) and, after a 1-month washout period, assessment aided by device outputs (post-AI arm). STAT and IT metrics were compared between the two arms. Results: This study included 285 CTAs (95 per reader, per arm) with a mean patient age of 58.5 years ±14.7 (SD), of which 52% were male and 37% had a prevalence of AD. AI assistance significantly reduced the STAT for detecting 33 true positive AD cases from 15.84 min (95% CI: 13.37–18.31 min) without AI to 5.07 min (95% CI: 4.23–5.91 min) with AI, representing a 68% reduction (p < 0.01). The IT also reduced significantly from 21.22 s (95% CI: 19.87–22.58 s) without AI to 14.17 s (95% CI: 13.39–14.95 s) with AI (p < 0.05). Conclusions: The integration of a DL-based algorithm for AD detection on chest CTAs significantly reduces both the STAT and IT. By prioritizing urgent cases, the AI-assisted approach outperforms the standard First-In, First-Out (FIFO) workflow.

7 January 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
JSJinkyeong Sung
Jinkyeong Sung
PCPeter D. Chang
Peter D. Chang
Angela AyobiAngela Ayobi
Angela Ayobi
MCMartina Cotena
Martina Cotena
MRMar Roca-Sogorb
Mar Roca-Sogorb
YCYasmina Chaibi
Yasmina Chaibi
Background/Objectives: While previous studies have evaluated AI algorithms for cervical spine fracture (CSFx) detection on CT, many have lacked validation on diverse, multinational datasets or have focused primarily on overall case-level classification This study aimed to evaluate the performance of an AI application for acute CSFx detection in case-level classification, fracture localization, and spinal level labeling on multicenter, multinational, and multivendor CT data. Methods: Non-enhanced CTs were retrospectively collected from a U.S. teleradiology company, a French teleradiology company, and a U.S. university hospital. Four radiologists independently labeled the presence and location (including the spinal level) of acute CSFx to establish the reference standard. Per-case diagnostic performance, per-bounding box positive predictive value (PPV) for localization, and overall agreement of cervical vertebral level labeling of the AI were assessed. Results: A total of 155 patients (60.6 years ± 21.2 years, 104 men) with acute CSFx and 173 patients (51.9 years ± 22.7 years, 91 men) without acute CSFx were evaluated. Data were acquired using scanners from five manufacturers. For acute CSFx diagnosis, the AI achieved a per-case sensitivity of 90.3%, a specificity of 91.9%, an accuracy of 91.2%, an area under the receiver operating characteristic curve (AUC) of 0.91, and Matthews correlation coefficient of 0.82. Among 192 bounding boxes representing acute CSFx generated for 154 positive cases by the AI, 162 were true positives (per-bounding box PPV, 84.4%). Of the 186 bounding boxes for which the AI displayed cervical spinal level, 181 were labeled correctly (overall agreement, 97.3%). Conclusions: The AI application for detecting acute CSFx demonstrated high diagnostic performance on multicenter, multinational, and multivendor data, with high performance in fracture localization and spinal level labeling.

16 January 2026 in Environmental Science: Nano
Verified
Journal Article
Closed access
PDF file
AOAmazigh Ouaksel
Amazigh Ouaksel
DSDanielle Slomberg
Danielle Slomberg
MCMartina Cotena
Martina Cotena
LBLenka Brousset
Lenka Brousset
BABernard Angeletti
Bernard Angeletti
MAMelanie Auffan
Melanie Auffan
Assessing the environmental risks of emerging contaminants related to new technologies remains a major challenge due to the diversity of pollutants, their complex interactions, and the limitations of conventional testing frameworks. Among these contaminants, engineered nanomaterials (ENMs) stand out for their unique surface reactivities and transformation pathways, which can significantly alter their behavior and that of co-occurring pollutants. Although many studies have addressed the toxicity and fate of individual ENMs, real-world scenarios often involve complex mixtures, whose combined effects are less investigated. This study addresses this gap by investigating the fate, behavior, and ecological impacts of a mixture of two representative metal oxide ENMs i.e. an industrial TiO2 and a combustion-derived CeO2. This study shows that under environmentally relevant conditions using freshwater mesocosms, these two ENMs undergo primary hetero-aggregation. Co-exposure of the freshwater snail Planorbarius corneus revealed that ENM aggregates (homo- or primary hetero-aggregates) interact with egg layings, potentially affecting early developmental stages, while slight but measurable uptakes were also observed in co-exposed adult snails. Importantly, no quenching of reactive oxygen species generated by the photocatalytic TiO2 was detected in the presence of CeO2, suggesting that the combusted CeO2 does not mitigate potentially TiO2-induced phototoxicity. These findings underscore the importance of considering ENM mixtures in environmental risk assessments and the relevance of mesocosm experiments to capture realistic exposure scenarios. Future studies should prioritize investigating how unique surface reactivities and transformation mechanisms of ENM mixtures shape their ecological impacts throughout their life cycles.

16 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MCMartina Cotena
Martina Cotena
Angela AyobiAngela Ayobi
Angela Ayobi
CZColin Zuchowski
Colin Zuchowski
JJJacqueline C. Junn
Jacqueline C. Junn
Brent WeinbergBrent Weinberg
Brent Weinberg
SQsarah Quenet
sarah Quenet
Background and Objectives: Acute aortic dissection (AD) is a life-threatening condition and early detection can significantly improve patient outcomes and survival. This study evaluates the clinical benefits of integrating a deep-learning (DL)-based application for automated detection and prioritisation of AD on chest CT angiographies (CTAs), focusing on the reduction of scan-to-assessment (STAT) and interpretation times (IT). Materials and Methods: This retrospective Multi-Reader, Multi-Case (MRMC) study compared AD detection with and without artificial intelligence-(AI) assistance. Ground truth was established by two U.S. board-certified radiologists, while three additional expert radiologists participated as readers. All participants assessed the same CTAs without AI-assistance (pre-AI arm) and, after a 1-month washout period, with the help of the device outputs (post-AI arm). STAT and IT were compared between the two phases. Results: The study included 285 CTAs (95 per reader, per arm), with a mean patient age of 58.5 years ±14.7(SD), 52% men, 37% prevalence. AI assistance significantly reduced STAT for detecting 33 true positive AD cases, from 15.84 minutes (95% CI: 13.37–18.31min) without AI to 5.07 minutes (95% CI: 4.23–5.91min) with AI, a 68% reduction (p<0.01). IT also decreased significantly, from 21.22 seconds (95% CI: 19.87–22.58s) without AI to 14.17 seconds (95% CI: 13.39–14.95s) with AI (p<0.05). Conclusions: Integrating a DL-based algorithm for AD detection on chest CTAs significantly reduces both STAT and IT. By prioritising the most urgent cases, AI ensures faster diagnosis and improves the workflow efficiency in clinical radiology practice, compared to standard First-In First-Out (FIFO) workflow.

27 June 2026 in Neuroscience Informatics
Verified
Journal Article
Open access
ABAlexandre Bani-Sadr
Alexandre Bani-Sadr
MCMartina Cotena
Martina Cotena
YCYasmina Chaibi
Yasmina Chaibi
PCPeter D. Chang
Peter D. Chang
DCDaniel S. Chow
Daniel S. Chow
Angela AyobiAngela Ayobi
Angela Ayobi