Field emission is an important work mode for electron sources, and carbon nanotubes (CNTs) have been extensively studied for their good emission properties. It is well known that the parameters of the grid deeply influence the field emission performance of CNTs, a relationship that requires further elucidation. Therefore, in this study, the relationship between the grid aperture ratio and electron transmittance was studied through simulations and experiments. This study’s results indicate that the electron transmittance improved as the grid aperture ratio increased. Meanwhile, electron beam spot simulations and imaging experiments indicate that an increased grid aperture ratio will expand the cathode electron divergence, leading to a larger electron beam spot size. These results demonstrate that there is a trade-off in maintaining the grid aperture ratio between high electron transmittance and relatively small electron beam spot size, and the optimum grid aperture ratio is between 75% and 85%. These results will provide a reference for the design and optimization of X-ray tubes and other electron sources.
Carbon nanotube (CNT) cathode materials exhibit excellent electron emission performance and have become a key research focus in the field of vacuum electronics. However, their practical applications are still restricted by challenges, including emission instability and ambiguity in temporal resolution capability. This work investigated the thermal-assisted field emission characteristics of CNT and their application in pulsed X-ray imaging. Systematic characterization of the turn-on field strength, emission stability, pulse response characteristics, and pulsed X-ray imaging performance demonstrated that the thermal-assisted operating mode reduced current fluctuations to below 1%. Increasing the heating power further enhanced emission stability and lowered the turn-on field strength. In thermal-assisted pulsed emission mode, CNT cathodes exhibited reduced power consumption compared to conventional thermionic cathodes and achieved microsecond-scale pulse response. Further X-ray imaging experiments confirmed that the X-ray dose generated by CNT in this operational mode exhibited higher stability, enabling 100 μs pulsed imaging and clear visualization of rotating blades operating at 600 Hz. This study validated the feasibility of CNT cathodes for high-speed X-ray imaging and could provide a reference for the development of advanced pulsed X-ray sources and related technologies.
The integration of active learning methods and multi-fidelity (MF) Kriging models has been demonstrated to effectively reduce the number of high-fidelity (HF) samples required for reliability analysis. However, there is a lack of comparative research on different MF Kriging models in this context. In this work, the performances of the hierarchical Kriging model, dis-Kriging model, and Co-Kriging model are compared within one-stage and two-stage active learning frameworks through five numerical examples. The total cost, the number of HF samples required, and the stability of estimated failure probability are utilized to facilitate a comparative analysis of different MF Kriging models. The results from the five examples indicate the following: the hierarchical Kriging model demonstrates a satisfactory performance in both one-stage and two-stage frameworks; the dis-Kriging model is not adequately equipped to handle complex, highly nonlinear problems; and the Co-Kriging model exhibits a lack of robustness, though it performs well in certain cases.