Jai Scheerhoorn

Dr. Jai Scheerhoorn


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FJFleur Jacobs
Fleur Jacobs
JSJai Scheerhoorn
Jai Scheerhoorn
EMEveline Mestrom
Eveline Mestrom
JSJonna van der Stam
Jonna van der Stam
RBR. Arthur Bouwman
R. Arthur Bouwman
SNSimon Nienhuijs
Simon Nienhuijs
Recognition of early signs of deterioration in postoperative course could be improved by continuous monitoring of vital parameters. Wearable sensors could enable this by wireless transmission of vital signs. A novel accelerometer-based device, called Healthdot, has been designed to be worn on the skin to measure the two key vital parameters respiration rate (RespR) and heart rate (HeartR). The goal of this study is to assess the reliability of heart rate and respiration rate measured by the Healthdot in comparison to the gold standard, the bedside patient monitor, during the postoperative period in bariatric patients. Data were collected in a consecutive group of 30 patients who agreed to wear the device after their primary bariatric procedure. Directly after surgery, a Healthdot was attached on the patients’ left lower rib. Vital signs measured by the accelerometer based Healthdot were compared to vital signs collected with the gold standard patient monitor for the period that the patient stayed at the post-anesthesia care unit. Over all patients, a total of 22 hours of vital signs obtained by the Healthdot were recorded simultaneously with the bedside patient monitor data. 87.5% of the data met the pre-defined bias of 5 beats per minute for HeartR and 92.3% of the data met the pre-defined bias of 5 respirations per minute for RespR. The Healthdot can be used to accurately derive heart rate and respiration rate in postbariatric patients. Wireless continuous monitoring of key vital signs has the potential to contribute to earlier recognition of complications in postoperative patients. Future studies should focus on the ability to detect patient deterioration in low-care environments and at home after discharge from the hospital.

1 April 2022 in European Journal of Surgical Oncology
Verified
Journal Article
Open access
JSJonna A. van der Stam
Jonna A. van der Stam
EMEveline Mestrom
Eveline Mestrom
JSJai Scheerhoorn
Jai Scheerhoorn
FJFleur Jacobs
Fleur Jacobs
IHIgnace H.J.T. de Hingh
Ignace H.J.T. de Hingh
RBR. Arthur Bouwman
R. Arthur Bouwman
Recent advances in wearable technology allow for the development of wirelessly connected sensors to continuously measure vital parameters in the general ward or even at home. The present study assesses the accuracy of a wearable patch (Healthdot) for continuous monitoring of heartrate (HR) and respiration rate (RR). The Healthdot measures HR and RR by means of chest accelerometry. The study population consisted of patients following major abdominal oncological surgery. The analysis focused on the agreement between HR and RR measured by the Healthdot and the gold standard patient monitor in the intensive and post-anesthesia care unit. For HR, a total of 112 h of measurements was collected in 26 patients. For RR, a total of 102 h of measurements was collected in 21 patients. On second to second analysis, 97% of the HR and 87% of the RR measurements were within 5 bpm and 3 rpm of the reference monitor. Assessment of 5-min averaged data resulted in 96% of the HR and 95% of the RR measurements within 5 bpm and 3 rpm of the reference monitor. A Clarke error grid analysis showed that 100% of the HR and 99.4% of the 5-min averaged data was clinically acceptable. The Healthdot accurately measured HR and RR in a cohort of patients recovering from major abdominal surgery, provided that good quality data was obtained. These results push the Healthdot forward as a clinically acceptable tool in low acuity settings for unobtrusive, automatic, wireless and continuous monitoring.

20 February 2023 in JMIR Perioperative Medicine
Verified
Journal Article
Open access
JSJonna A van der Stam
Jonna A van der Stam
EMEveline Mestrom
Eveline Mestrom
JSJai Scheerhoorn
Jai Scheerhoorn
FJFleur E N B Jacobs
Fleur E N B Jacobs
SNSimon W. Nienhuijs
Simon W. Nienhuijs
RBR. Arthur Bouwman
R. Arthur Bouwman
Background: Postoperative deterioration is often preceded by abnormal vital parameters. Therefore, vital parameters of postoperative patients are routinely measured by nursing staff. Wrist-worn sensors could potentially provide an alternative tool for the measurement of vital parameters in low-acuity settings. These devices would allow more frequent or even continuous measurements of vital parameters without relying on time-consuming manual measurements, provided their accuracy in this clinical population is established. Objective: This study aimed to assess the accuracy of heart rate (HR) and respiratory rate (RR) measures obtained via a wearable photoplethysmography (PPG) wristband in a cohort of postoperative patients. Methods: The accuracy of the wrist-worn PPG sensor was assessed in 62 post–abdominal surgery patients (mean age 55, SD 15 years; median BMI 34, IQR 25-40 kg/m2). The wearable obtained HR and RR measurements were compared to those of the reference monitor in the postanesthesia or intensive care unit. Bland-Altman and Clarke error grid analyses were performed to determine agreement and clinical accuracy. Results: Data were collected for a median of 1.2 hours per patient. With a coverage of 94% for HR and 34% for RR, the device was able to provide accurate measurements for the large majority of the measurements as 98% and 93% of the measurements were within 5 bpm or 3 rpm of the reference signal. Additionally, 100% of the HR and 98% of the RR measurements were clinically acceptable on Clarke error grid analysis. Conclusions: The wrist-worn PPG device is able to provide measurements of HR and RR that can be seen as sufficiently accurate for clinical applications. Considering the coverage, the device was able to continuously monitor HR and report RR when measurements of sufficient quality were obtained. Trial Registration: ClinicalTrials.gov NCT03923127; https://www.clinicaltrials.gov/ct2/show/NCT03923127

21 January 2022 in Trials
Verified
Journal Article
Open access
PDF file
JSJai Scheerhoorn
Jai Scheerhoorn
LELisa van Ede
Lisa van Ede
MLMisha D. P. Luyer
Misha D. P. Luyer
MBMarc P. Buise
Marc P. Buise
RBR. Arthur Bouwman
R. Arthur Bouwman
SNSimon W. Nienhuijs
Simon W. Nienhuijs
Introduction: Performing bariatric surgery in a daycare setting has a potential reduction in hospital costs and increase in patients’ satisfaction. Although the feasibility and safety of such care pathway has already been proven, its implementation is hampered by concerns about timely detection of short-term complications. This study is designed to evaluate a combined outcome measurement in outpatient bariatric surgery supplemented by a novel wireless remote monitoring system versus current standard of care. Methods and analysis: A total of 200 patients with multidisciplinary team approval for primary bariatric surgery will be assigned based on their preference to one of two postoperative trajectories: (1) standard of in-hospital care with discharge on the first postoperative day or (2) same day discharge with ongoing telemonitoring up to 7 days after surgery. The device (Healthdot R Philips) transfers heart rate, respiration rate, activity, and body posture of the patient continuously by LoRaWan network to our hospital’s dashboard (Philips Guardian). The primary outcome is a composite outcome measure within 30 days postoperative based on mortality, mild and severe complications, readmission, and prolonged length-of-stay. Secondary outcomes include patients’ satisfaction and data handling dimensions. Trial registration: ClinicalTrials.gov NCT04754893, Registered on 12 February 2021.

23 June 2022 in JMIR Preprints
Verified
Preprint
Open access
JSJonna A van der Stam
Jonna A van der Stam
EMEveline Mestrom
Eveline Mestrom
JSJai Scheerhoorn
Jai Scheerhoorn
FJFleur E N B Jacobs
Fleur E N B Jacobs
SNSimon W. Nienhuijs
Simon W. Nienhuijs
RBR. Arthur Bouwman
R. Arthur Bouwman
BACKGROUND Postoperative deterioration is often preceded by abnormal vital parameters. Therefore, vital parameters of postoperative patients are routinely measured by nursing staff. Wrist-worn sensors could potentially provide an alternative tool for the measurement of vital parameters in low-acuity settings. These devices would allow more frequent or even continuous measurements of vital parameters without relying on time-consuming manual measurements, provided their accuracy in this clinical population is established. OBJECTIVE This study aimed to assess the accuracy of heart rate (HR) and respiratory rate (RR) measures obtained via a wearable photoplethysmography (PPG) wristband in a cohort of postoperative patients. METHODS The accuracy of the wrist-worn PPG sensor was assessed in 62 post–abdominal surgery patients (mean age 55, SD 15 years; median BMI 34, IQR 25-40 kg/m2). The wearable obtained HR and RR measurements were compared to those of the reference monitor in the postanesthesia or intensive care unit. Bland-Altman and Clarke error grid analyses were performed to determine agreement and clinical accuracy. RESULTS Data were collected for a median of 1.2 hours per patient. With a coverage of 94% for HR and 34% for RR, the device was able to provide accurate measurements for the large majority of the measurements as 98% and 93% of the measurements were within 5 bpm or 3 rpm of the reference signal. Additionally, 100% of the HR and 98% of the RR measurements were clinically acceptable on Clarke error grid analysis. CONCLUSIONS The wrist-worn PPG device is able to provide measurements of HR and RR that can be seen as sufficiently accurate for clinical applications. Considering the coverage, the device was able to continuously monitor HR and report RR when measurements of sufficient quality were obtained. CLINICALTRIAL ClinicalTrials.gov NCT03923127; https://www.clinicaltrials.gov/ct2/show/NCT03923127

Verified
Journal Article
Open access
PDF file
JSJai Scheerhoorn
Jai Scheerhoorn
MFMax Herman Funnekotter
Max Herman Funnekotter
FSFriso Schonck
Friso Schonck
RBR. Arthur Bouwman
R. Arthur Bouwman
SNSimon W. Nienhuijs
Simon W. Nienhuijs
Background: Obesity and its accompanying complications have an influence on diurnal rhythm, potentially causing cardiometabolic disease. This study explores how weight loss due to bariatric surgery affects circadian rhythm disruptions measurable through wearable heart rate monitors. Methods: A single-center observational study was performed, in which patients who had undergone primary bariatric surgery 3 years ago with telemonitoring of vital parameters using a wireless accelerometer were eligible to participate. A Wilcoxon signed-rank test was conducted to evaluate the delta of, or amount of change in, circadian patterns between the baseline (before) and post-weight-loss peak, nadir, and peak–nadir heart rates. Results: In this cohort of 69 patients, 70% were female, with a median total weight loss of 31.4% towards a median BMI of 28.4 kg/m2. Analysis revealed significant changes in peak–nadir excursions post-weight loss. Peak, nadir, and peak–nadir differences showed a significant reduction in values in the post-weight-loss group. No significant correlations between other clinical endpoints and change in peak–nadir excursion were found in the multivariable regression models. Conclusions: In conclusion, this study reveals significant changes in circadian heart rate patterns before and after weight loss due to metabolic surgery. The results could add to the health benefits of bariatric surgery, as it could lower the incidence of diseases associated with changes in diurnal rhythm due to obesity. However, a clear clinical explanation is lacking, as no correlation with total weight loss nor other variables was substantiated.