Background: Inertial hamstring exercises promote functional changes leading to lower rates of hamstring injuries. However, variable training measurement systems have not been specifically validated for hamstring exercises. Accordingly, this study aimed to evaluate the validity of the Inertial Measurement System (IMS) to measure the velocity, force, and power during the performance of different hamstring exercises on a flywheel resistance training device. Methods: Fifteen males (average age: 22.4 ± 2.5 years; body mass: 77.3 ± 9.8 kg; height: 179.5 ± 7.4 cm; weekly physical activity: 434.0 ± 169.2 min; years of strength training: 4.3 ± 2.2 years) performed the bilateral stiff-leg deadlift (SDL), 45° hip extension (HE), and unilateral straight knee bridge (SKB) in two sessions (familiarization and evaluation) with a 1-week interval between them. The velocity, force, and power (average and peak values) in the concentric and eccentric phases for each of the exercises were recorded simultaneously with IMS and MuscleLab. Results: Consistency between IMS and MuscleLab was good to excellent for all variables, with r ranges from 0.824 to 0.966 in SDL, from 0.822 to 0.971 in HE, and from 0.806 to 0.969 in SKB. Acceptable levels of agreement between devices were observed in general for all exercises, the “bias” ranging from 1.1% to 13.2%. Although MuscleLab showed higher values than IMS for peak velocity, force and power values, the effect size was only relevant for 5 of the 36 parameters. IMS is a new and valid system to monitor inertial hamstring exercises on a new flywheel device. In this way, IMS could have potential practical applications for any professional or athlete who wants to monitor inertial hamstring exercises.
Background: Neck pain has a high annual incidence and decreases the cervical active range of motion (ROM). Clinicians use various methods to evaluate cervical range of motion (CROM) that some of them have also been proposed to give instant feedback. Accordingly, this study aimed to examine the validity and reliability of Veloflex (VF) to measure the CROM by comparison with the cervical range of motion (CROM) device, and to examine their test-retest reliability. Methods: Thirty-eight healthy and 20 symptomatic participants were evaluated. Cervical flexion-extension, side bending, and rotations were tested in two sessions, first by the CROM and VF and in the second only with the VF. To evaluate the concurrent validity and agreement between CROM and VF, Pearson correlation coefficient (r) and Bland–Altmann plots were used. Reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM) and minimal detectable change (MDC). Results: CROM and VF showed excellent correlation for all movements (r > 0.960). Both devices provided small mean ‘bias’ (≤1.29%) in all movements regarding CROM measures. The intra-rater and inter-rater reliability of the VF was excellent (ICC > 0.98). SEMs ranging from 0.72% to 2.38% and the MDC ranging from 1.22° to 2.60° in all participants. The results support the validity and reliability of VF to measure CROM. For its use, with a basic training is enough to get reliable measurements.
(1) Background: Dynamic balance plays a crucial role in maintaining ankle stability and preventing injuries, particularly in active individuals. Instability devices are commonly utilized to enhance ankle strength and stability, and there is growing interest in integrating these tools with novel modalities, such as transcranial direct current stimulation (tDCS), to maximize benefits. This study aimed to compare the effects of a 4-week balance training program performed on a selective instability device alone or combined with tDCS on dynamic balance in recreationally active young adults. (2) Methods: Twenty participants were randomized into two groups: one performing balance exercises on the Blackboard device and another combining the exercises with tDCS. Dynamic balance was measured at baseline, midway, and post-intervention using the Y-Balance Test and the Emery Test. (3) Results: Both groups showed significant improvements in balance performance, with increased reach distances and stability times (p = 0.001 and p = 0.04, respectively), after 4 weeks. However, the addition of tDCS did not yield additional benefits over balance training alone (p > 0.05). (4) Conclusions: These findings underscore the value of instability device-based balance training for enhancing dynamic balance while questioning the utility of tDCS as a combined therapy in healthy individuals.
Background/Objectives: Both Sides Utilized it is one of the most employed global instability devices (GID), but it is difficult to progress and select a particular foot structure. In this sense, the Blackboard has been created as selective instability device (SID). The aim of this study is to compare the effects of both devices on balance and ankle stability. Methods: The study was designed as a randomized controlled clinical trial. Twenty healthy amateur soccer players were divided into two groups: GID and SID. Both performed balance training (4-weeks, 3 days/week). Ankle balance and stability were assessed. Paired t-tests were used to analyze the pre-, post-, and between-groups differences. Results: No differences were found between the groups. Significant intra-group changes were found in both groups for posterolateral balance and summation. Moreover, posteromedial balance increased in the GID group. No changes were found in ankle stability results. Conclusions: A balance intervention using GID or SID is effective in improving general and posterolateral balance. Moreover, the GID intervention improved posteromedial balance.
Background: Balance training exercises are essential for treating and preventing a variety of ankle conditions such as sprains, chronic ankle instability, and muscular weakness. This muscle activation could often be increased using unstable devices. The Blackboard is a new configurable selective instability device, that has the potential to focus directly on desired muscles without overloading others through wooden half cylinders slats joined to a board by a tape in different positions. Depending on the position where they are situated, different stability training could be performed. However, its specific muscle activation patterns remain unknown. Methods: Surface electromyography was used to measure the activation level of six lower-leg muscles (i.e., soleus, gastrocnemius medialis, gastrocnemius lateralis, tibialis anterior, peroneus longus, and peroneus brevis) in a single-leg stance on the floor and on seven Blackboard configurations. Thirty healthy active subjects participated in the study. Results: Multiple differences in muscle activation were observed between conditions and among muscles. Notably, the tibialis anterior and the peroneus showed the greatest differences between conditions and the highest activation levels on the Blackboard. Additionally, forefoot supination and rearfoot eversion configurations induced selective activation of the tibialis anterior and peroneus longus, respectively, highlighting their usefulness for isolating specific muscle contractions.
Background: Stabilometry, the modified Star Excursion Balance Test (mSEBT) or the Emery balance test (EBT) are reported in the literature to reflect changes after an intervention in monopodal postural stability. Even so, the responsiveness of those tests has not been evaluated after an instability training programme or analysed using multiple statistical indicators of responsiveness. The main aim of this study was to analyse the responsiveness of the stabilometry, mSEBT or EBT. Methods: Thirty healthy recreational athletes performed a 4-week programme with three weekly sessions of instability training of the dominant lower limb and were evaluated using stabilometry, mSEBT, and EBT tests. Responsiveness was quantified based on internal and external responsiveness. Results: EBT and all parameters in mSEBT for the dominant lower limb showed large internal responsiveness (SRM > 0.8). Furthermore, mSEBT values for the non-dominant lower limb (except anterior displacement) also experienced significant changes with an associated large internal responsiveness. None of the stabilometry platform parameters showed a significant change after the intervention. The ability of the EBT to discriminate between the dominant and non-dominant lower limb (i.e., trained vs untrained, respectively) was generally acceptable (AUCs = 0.708). However, none of the parameters of the mSEBT test showed an acceptable AUC. Conclusions: EBT showed a positive responsiveness after instability training compared to mSEBT, which only showed internal responsiveness, or stabilometry platform measures, whose none of the parameters could identify these changes.