In Japan, the use of implantable cardioverter defibrillators (ICDs), cardiac resynchronization therapy with a biventricular pacemaker (CRTP) and CRT with a defibrillator (CRTD) in children has not been studied statistically, and dual-chamber (DDD) pacemakers are still used for pediatric CRT because of current government regulations. Data were obtained from 15 children's and 74 general hospitals through a questionnaire survey regarding the aforementioned therapies performed before 2012 in Japanese children (<16 years old). ICD, CRT with DDD, CRTP and CRTD were used in 64 (42%), 47 (31%), 34 (22%) and 7 (5%), respectively, of all cases reported (n=152). Among all CRTP and CRT-DDD cases (n=81), the use of DDD accounted for 41% in general hospitals vs. 89% in children's hospitals, and CRT-DDD and CRTP were effective in 67 cases (83%). Of 64 ICD cases, appropriate shocks were experienced in 28 cases (44%), and inappropriate shocks in 19 cases (29%). Additionally, data from the Japan Arrhythmia Device Industry Association obtained for overall device usage analysis revealed that CRTP was more commonly used in children than in adults. There is an increasing need for pediatric device therapy, especially CRTP. However, many children's hospitals were still using DDD pacemakers in 2012. Although the demand for device therapy in children may be small, it is indispensable in pediatric cardiology.
Three-dimensional (3D) printing is an advanced technology for accurately understanding anatomy and supporting the successful surgical management of complex congenital heart disease (CHD). We aimed to evaluate whether our super-flexible 3D heart models could facilitate preoperative decision-making and surgical simulation for complex CHD. The super-flexible heart models were fabricated by stereolithography 3D printing of the internal and external contours of the heart from cardiac computed tomography (CT) data, followed by vacuum casting with a polyurethane material similar in elasticity to a child’s heart. Nineteen pediatric patients with complex CHD were enrolled (median age, 10 months). The primary endpoint was defined as the percentage of patients rated as “essential” on the surgeons’ postoperative 5-point Likert scale. The accuracy of the models was validated by a non-destructive method using industrial CT. The super-flexible heart models allowed detailed anatomical diagnosis and simulated surgery with incisions and sutures. Thirteen patients (68.4%) were classified as “essential” by the primary surgeons after surgery, with a 95% confidence interval of 43.4–87.4%, meeting the primary endpoint. The product error within 90% of the total external and internal surfaces was 0.54 ± 0.21 mm. The super-flexible 3D heart models are accurate, reliable, and useful tools to assist surgeons in decision-making and allow for preoperative simulation in CHD.
Background:In Japan, the choice of pediatric medical devices is limited because of 2 “device lag” problems: Japan lags behind the USA and Europe in device development, and development of pediatric devices lags behind that of adult devices. We aimed to identify the problems with and impediments to pediatric medical device development as recognized by pediatric physicians in Japan.Methods and Results:A voluntary survey of pediatric medical devices for all council members of the Japanese Society of Pediatric Cardiology and Cardiac Surgery was conducted in 2019. The response rate was 47.1% (154/327). The respondents were 115 pediatric cardiologists (74.7%) and 39 cardiovascular surgeons (25.3%). Approximately 90% believed that difficulties in development existed. Approximately 70% were dissatisfied with the pediatric medical devices currently available in Japan, which was a result of the unavailability of medical devices approved overseas, few types and sizes, and off-label use. Factors that hindered the development of pediatric medical devices included anatomical issues specific to children with congenital heart disease, as well as system issues such as lack of corporate profitability, development cost, and amount of time for development.Conclusions:Pediatric cardiologists and cardiovascular surgeons regard “device lag” and “off-label use” in Japan as important hindrances to the delivery of better medical care for pediatric patients with congenital heart disease.