The retrofitting of existing public buildings to save energy and reduce carbon emissions is a priority for China’s building sector. Accordingly, the Chinese government requires all public buildings to be energy retrofitted based on the Design Standard for Energy Efficiency of Public Buildings GB50189-2015. However, few studies have been conducted to assess the energy efficiency of this design standard in the hot summer and cold winter (HSCW) climate region of China. The aim of this study was therefore to provide sensitivity analysis for the thermal properties of the envelope of a typical public building energy retrofit in China’s HSCW climate region. The results show that the thermal performance of the existing envelope of the sample building was very poor, with heating and cooling energy consumption 18.94% higher than the GB90189-2015 baseline model. It was found that better optimized parameters could reduce the heating and cooling energy load by 28.26% compared with the parameters of the sample building. The findings from this study provide valuable references for local governments and practitioners eager to improve the energy efficiency of existing public buildings in China’s HSCW region.
This study addresses the challenge of rapid identification and assessment of localized damage to building envelopes under resource-constrained conditions—specifically, the absence of specialized inspection equipment—with a particular focus on the detrimental effects of such damage on thermal performance and energy efficiency. An efficient detection methodology tailored to small-scale maintenance scenarios is proposed, leveraging the YOLOv11 object detection architecture to develop an intelligent system capable of recognizing common envelope defects in contemporary residential buildings, including cracks, spalling, and sealant failure. The system prioritizes the detection of anomalies that may induce thermal bridging, reduced airtightness, or insulation degradation. Defects are classified according to severity and their potential impact on thermal behavior, enabling a graded, integrated repair strategy that holistically balances structural safety, thermal restoration, and façade aesthetics. By explicitly incorporating energy performance recovery as a core objective, the proposed approach not only enhances the automation of spatial data processing but also actively supports the green operation and low-carbon retrofitting of existing urban building stock. Characterized by low cost, high efficiency, and ease of deployment, this method offers a practical and scalable technical pathway for the intelligent diagnosis of thermal anomalies and the enhancement of building energy performance. It aligns with the principles of high-quality architectural development and sustainable building governance, while concretely advancing operational energy reduction in the built environment and contributing meaningfully to energy conservation goals.
The moisture transfer coefficient is a key parameter for analyzing the moisture-based physical properties of materials and studying the heat–moisture coupling process within building envelopes. The liquid-water transfer coefficient, as an important aspect of this process, plays a significant role, especially under high-humidity conditions. However, the global research on liquid-water transfer coefficients is still far from complete. To further enhance the research on liquid-water transfer coefficients, this study conducted capillary water absorption experiments on seven traditional and new porous building materials, focusing on testing the moisture transfer coefficients, primarily the liquid-water transfer coefficient. A novel analysis regarding the impact of sealing materials was proposed, based on the experimental results. Based on the experimental data, the concept of a critical value related to the variation in the capillary moisture content and the liquid-water diffusion coefficient was raised, and, building upon traditional empirical models, a completely new computational model was proposed. Data processing was carried out using methods such as variability analysis, correlation analysis, and nonlinear regression for model fitting. The research findings indicate the following: (1) The capillary water absorption rate and capacity of a material are influenced by its density and porosity. (2) In terms of sealing materials, self-adhesive films performed better than non-adhesive films. (3) The concept of critical capillary moisture content was proposed, based on the rate of change in the liquid-water diffusion coefficient. For the threshold of ≤ 80%, a new calculation model with a higher correlation coefficient was proposed which can meet the calculation requirements of the diffusion coefficient under the vast majority of relative-humidity conditions.
Against the global backdrop of carbon neutrality and the green transition of the construction sector, modern timber-framed buildings have emerged as a core enabler of sustainable construction. However, a systematic synthesis of research on indoor hygrothermal environments and thermal comfort in such buildings remains lacking, and the underlying coupling mechanisms—as well as pathways for performance optimization—are still insufficiently understood. To address these gaps, this study aims to systematically characterize and evaluate the performance features of indoor thermal and moisture environments in modern timber buildings, and to identify the key influencing factors and their underlying mechanisms. In accordance with the PRISMA 2020 guidelines for systematic reviews, this study identified and analyzed 203 high-quality peer-reviewed publications retrieved from three major academic databases, covering the period 2010–2025. Specifically, the literature search was conducted across the Web of Science, Scopus, and the China National Knowledge Infrastructure (CNKI), and visualization analysis was performed using VOSviewer 1.6.20 software. The results indicate that timber-framed buildings exhibit distinctive indoor hygrothermal characteristics: rapid temperature response, strong humidity buffering capacity, and superior thermal insulation performance compared with concrete structures, enabling indoor relative humidity to remain stably within the thermally comfortable range. Nevertheless, challenges persist, including summer overheating and elevated risks of mold growth under hot-humid conditions. Furthermore, the PMV model demonstrates significant predictive deviation for thermal comfort in timber-framed buildings; its application thus requires calibration incorporating both the hygrothermal properties of timber materials and occupants’ psychological adaptation. This study synthesizes the current state of research, identifies key influencing factors, and proposes climate-responsive optimization strategies to advance the development of robust thermal comfort models and support the low-energy, high-comfort design of timber-framed buildings.
This study initially examined the thermal comfort of rural residents in southern Jiangsu, analyzing their tolerance levels and expected temperature ranges during winter and summer. Subsequently, Design Builder 7.02.004 software was utilized to simulate the energy consumption of typical residential buildings. Furthermore, an orthogonal test method was employed to investigate the significant relationships among seven factors influencing building energy consumption in both winter and summer. These factors include external wall heat transfer coefficient, roof heat transfer coefficient, external window heat transfer coefficient, external window solar heat gain coefficient (SHGC), window-to-wall-area ratio, air tightness, and building orientation. Finally, based on the findings from the thermal comfort study, recommended passive design parameters for near-zero-energy residential buildings in southern Jiangsu were proposed. This provides valuable references for the future construction efforts of such buildings within this region.